A Preliminary Design of Central Monitoring╱Controlling System for Hemodialysis

碩士 === 中原大學 === 醫學工程學系 === 82 === In this paper, a preliminary monitoring and controlling system has been developed consisting of a personal computer with a dia- lysis machine. The serial interfaces including a singal process- ing card , Multi-8255 and an...

Full description

Bibliographic Details
Main Authors: Yu, Keh Chung, 于克忠
Other Authors: Chang, Yen Lin
Format: Others
Language:zh-TW
Published: 1994
Online Access:http://ndltd.ncl.edu.tw/handle/93193929634935527868
id ndltd-TW-082CYCU0530017
record_format oai_dc
spelling ndltd-TW-082CYCU05300172016-02-10T04:08:56Z http://ndltd.ncl.edu.tw/handle/93193929634935527868 A Preliminary Design of Central Monitoring╱Controlling System for Hemodialysis 血液透析中心中央監控站初形開發 Yu, Keh Chung 于克忠 碩士 中原大學 醫學工程學系 82 In this paper, a preliminary monitoring and controlling system has been developed consisting of a personal computer with a dia- lysis machine. The serial interfaces including a singal process- ing card , Multi-8255 and an AD/DA interface card, were used for communication. By using the developed software in C language , graphics are created for monitoring the dialysis machine so that patient and system conditions may be easily understood. The moni- toring conditions include dialysate temperature,venous pressure, dialysate pressure , conductivity of dialysate ,total amount of ultrafilteration ,target of ultrafilteration , ultrafilteration rate, blood flow rate,blood leak and air bubble.The control sys- tem include the comfortable dialysis programing control of blood flow rate,the alteration of setting the mode of dialysis machine and the threshold of monitoring items. In this investigation, we execute preliminary for the central monitoring /controlling sys- tem and try to expand connecting with two dialysis machines. The singal processing card has been accomplished and produced.In hos- pital,the system is reliable and safe during the dialysis The system is now available that allow for monitoring and cont- roling one dialysis machine. In the future , it can connect with multi-dialysis machines to construct a network system . It will reduce the burden of physician and increase the safety of patient during dialysis treatment.84 Chang, Yen Lin 張炎林 1994 學位論文 ; thesis 120 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中原大學 === 醫學工程學系 === 82 === In this paper, a preliminary monitoring and controlling system has been developed consisting of a personal computer with a dia- lysis machine. The serial interfaces including a singal process- ing card , Multi-8255 and an AD/DA interface card, were used for communication. By using the developed software in C language , graphics are created for monitoring the dialysis machine so that patient and system conditions may be easily understood. The moni- toring conditions include dialysate temperature,venous pressure, dialysate pressure , conductivity of dialysate ,total amount of ultrafilteration ,target of ultrafilteration , ultrafilteration rate, blood flow rate,blood leak and air bubble.The control sys- tem include the comfortable dialysis programing control of blood flow rate,the alteration of setting the mode of dialysis machine and the threshold of monitoring items. In this investigation, we execute preliminary for the central monitoring /controlling sys- tem and try to expand connecting with two dialysis machines. The singal processing card has been accomplished and produced.In hos- pital,the system is reliable and safe during the dialysis The system is now available that allow for monitoring and cont- roling one dialysis machine. In the future , it can connect with multi-dialysis machines to construct a network system . It will reduce the burden of physician and increase the safety of patient during dialysis treatment.84
author2 Chang, Yen Lin
author_facet Chang, Yen Lin
Yu, Keh Chung
于克忠
author Yu, Keh Chung
于克忠
spellingShingle Yu, Keh Chung
于克忠
A Preliminary Design of Central Monitoring╱Controlling System for Hemodialysis
author_sort Yu, Keh Chung
title A Preliminary Design of Central Monitoring╱Controlling System for Hemodialysis
title_short A Preliminary Design of Central Monitoring╱Controlling System for Hemodialysis
title_full A Preliminary Design of Central Monitoring╱Controlling System for Hemodialysis
title_fullStr A Preliminary Design of Central Monitoring╱Controlling System for Hemodialysis
title_full_unstemmed A Preliminary Design of Central Monitoring╱Controlling System for Hemodialysis
title_sort preliminary design of central monitoring╱controlling system for hemodialysis
publishDate 1994
url http://ndltd.ncl.edu.tw/handle/93193929634935527868
work_keys_str_mv AT yukehchung apreliminarydesignofcentralmonitoringcontrollingsystemforhemodialysis
AT yúkèzhōng apreliminarydesignofcentralmonitoringcontrollingsystemforhemodialysis
AT yukehchung xuèyètòuxīzhōngxīnzhōngyāngjiānkòngzhànchūxíngkāifā
AT yúkèzhōng xuèyètòuxīzhōngxīnzhōngyāngjiānkòngzhànchūxíngkāifā
AT yukehchung preliminarydesignofcentralmonitoringcontrollingsystemforhemodialysis
AT yúkèzhōng preliminarydesignofcentralmonitoringcontrollingsystemforhemodialysis
_version_ 1718185716787183616