The Simultaneous Analysis of Aliphatic Chlorides in Air by Gas Chromatography ╱ Mass Spectrometry

碩士 === 逢甲大學 === 化學工程研究所 === 81 === The pretreatment in trace analyses for organic polluants in ambient air were necessary in Capillary column gas chromatogra- phic techniques. The concentration and desorption processes of the pretreatm...

Full description

Bibliographic Details
Main Authors: YANG,Shwu Jiuan, 楊淑娟
Other Authors: LIN,Ping Jei
Format: Others
Language:zh-TW
Published: 1993
Online Access:http://ndltd.ncl.edu.tw/handle/83642863265832227122
id ndltd-TW-081FCU00063011
record_format oai_dc
spelling ndltd-TW-081FCU000630112015-10-13T17:44:42Z http://ndltd.ncl.edu.tw/handle/83642863265832227122 The Simultaneous Analysis of Aliphatic Chlorides in Air by Gas Chromatography ╱ Mass Spectrometry 空氣中有機氯化物之分析 YANG,Shwu Jiuan 楊淑娟 碩士 逢甲大學 化學工程研究所 81 The pretreatment in trace analyses for organic polluants in ambient air were necessary in Capillary column gas chromatogra- phic techniques. The concentration and desorption processes of the pretreatment were complex, time tedious,and might cause un- certain results. In this investigation ,a fourteen aliphatic chlorides (from C1 to C3) mixture sample has been analyzed by direct injection in packed column gas chromatography. Since the fourteen aliphatic chlorides were not completely separated by any single liquid phase packed column in gas chro- matography. The optimal separations of the mixed sample (Exclu- sion of 1,1 ,1-trichloroethane and dichloromethane) was found from the window diagram of two liquid phases with weight percen- tages of 70% OV-17 and 30% FFAP. The relative separation time ( Separation factor,alpha) of the poorest couple was 1.11 in the quantitative analysis of the mixed sample by using a two meters column packed with the above percentages of the liquid phases in mixed bed method. All fourteen aliphatic chlorides were measured quantita- tively in four different concentrations individually by using Gas Chromatohraphy ╱ Mass Spectrometry (GC╱MS) . Although 1,1,1- trichloroethane and dichloromethane were unable to be separated from the other twelve compounds,the characteristic fragment of those compounds,C2H3Cl2+ and C2H2Cl2+ ,were chosen to avoid the peak overlap from other compounds in the selective ion mode (SIM) method of the GC╱MS.The concentration of the fourteen compounds were obtained under the SIM method in sub-ppm levels with iodobu- tane as an internal standard. The results for chloroethane was even sensitive to ppb levels. The linear dynamic range of our mass spectrometer detector was over 3 orders of magnitude. LIN,Ping Jei 林屏杰 1993 學位論文 ; thesis 68 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 逢甲大學 === 化學工程研究所 === 81 === The pretreatment in trace analyses for organic polluants in ambient air were necessary in Capillary column gas chromatogra- phic techniques. The concentration and desorption processes of the pretreatment were complex, time tedious,and might cause un- certain results. In this investigation ,a fourteen aliphatic chlorides (from C1 to C3) mixture sample has been analyzed by direct injection in packed column gas chromatography. Since the fourteen aliphatic chlorides were not completely separated by any single liquid phase packed column in gas chro- matography. The optimal separations of the mixed sample (Exclu- sion of 1,1 ,1-trichloroethane and dichloromethane) was found from the window diagram of two liquid phases with weight percen- tages of 70% OV-17 and 30% FFAP. The relative separation time ( Separation factor,alpha) of the poorest couple was 1.11 in the quantitative analysis of the mixed sample by using a two meters column packed with the above percentages of the liquid phases in mixed bed method. All fourteen aliphatic chlorides were measured quantita- tively in four different concentrations individually by using Gas Chromatohraphy ╱ Mass Spectrometry (GC╱MS) . Although 1,1,1- trichloroethane and dichloromethane were unable to be separated from the other twelve compounds,the characteristic fragment of those compounds,C2H3Cl2+ and C2H2Cl2+ ,were chosen to avoid the peak overlap from other compounds in the selective ion mode (SIM) method of the GC╱MS.The concentration of the fourteen compounds were obtained under the SIM method in sub-ppm levels with iodobu- tane as an internal standard. The results for chloroethane was even sensitive to ppb levels. The linear dynamic range of our mass spectrometer detector was over 3 orders of magnitude.
author2 LIN,Ping Jei
author_facet LIN,Ping Jei
YANG,Shwu Jiuan
楊淑娟
author YANG,Shwu Jiuan
楊淑娟
spellingShingle YANG,Shwu Jiuan
楊淑娟
The Simultaneous Analysis of Aliphatic Chlorides in Air by Gas Chromatography ╱ Mass Spectrometry
author_sort YANG,Shwu Jiuan
title The Simultaneous Analysis of Aliphatic Chlorides in Air by Gas Chromatography ╱ Mass Spectrometry
title_short The Simultaneous Analysis of Aliphatic Chlorides in Air by Gas Chromatography ╱ Mass Spectrometry
title_full The Simultaneous Analysis of Aliphatic Chlorides in Air by Gas Chromatography ╱ Mass Spectrometry
title_fullStr The Simultaneous Analysis of Aliphatic Chlorides in Air by Gas Chromatography ╱ Mass Spectrometry
title_full_unstemmed The Simultaneous Analysis of Aliphatic Chlorides in Air by Gas Chromatography ╱ Mass Spectrometry
title_sort simultaneous analysis of aliphatic chlorides in air by gas chromatography ╱ mass spectrometry
publishDate 1993
url http://ndltd.ncl.edu.tw/handle/83642863265832227122
work_keys_str_mv AT yangshwujiuan thesimultaneousanalysisofaliphaticchloridesinairbygaschromatographymassspectrometry
AT yángshūjuān thesimultaneousanalysisofaliphaticchloridesinairbygaschromatographymassspectrometry
AT yangshwujiuan kōngqìzhōngyǒujīlǜhuàwùzhīfēnxī
AT yángshūjuān kōngqìzhōngyǒujīlǜhuàwùzhīfēnxī
AT yangshwujiuan simultaneousanalysisofaliphaticchloridesinairbygaschromatographymassspectrometry
AT yángshūjuān simultaneousanalysisofaliphaticchloridesinairbygaschromatographymassspectrometry
_version_ 1717784271255502848