Impacts of UV-H2O2 Treatment for Taste and Odour Control on Secondary Disinfection

The Cornwall Water Purification Plant collaborated with the University of Toronto to monitor UV-H2O2 treatment performance. This study includes a review of engineering and operational aspects of UV-H2O2 implementation. A number of operational challenges were experienced with retrofitting UV-H2O2 int...

Full description

Bibliographic Details
Main Author: Pantin, Sophie
Other Authors: Hofmann, Ronald
Language:en_ca
Published: 2009
Subjects:
Online Access:http://hdl.handle.net/1807/18973
id ndltd-TORONTO-oai-tspace.library.utoronto.ca-1807-18973
record_format oai_dc
spelling ndltd-TORONTO-oai-tspace.library.utoronto.ca-1807-189732013-11-01T04:11:27ZImpacts of UV-H2O2 Treatment for Taste and Odour Control on Secondary DisinfectionPantin, SophieUV-H2O2disinfection0543The Cornwall Water Purification Plant collaborated with the University of Toronto to monitor UV-H2O2 treatment performance. This study includes a review of engineering and operational aspects of UV-H2O2 implementation. A number of operational challenges were experienced with retrofitting UV-H2O2 into the existing treatment plant, and an overview of the challenges and solutions faced at Cornwall is given. The project also includes a thorough water quality analysis. Taste and odour (T&O) events have been monitored for three years and the efficiency of UV-H2O2 on T&O removal is reported. Furthermore, little is known about any potential side effects of the treatment on downstream processes, especially secondary disinfection. The impact of UV-H2O2 on natural organic matter alterations, chlorine stability and disinfection by-product formation is reported using results from full-scale water quality monitoring campaigns at Cornwall, combined with laboratory experiments.Hofmann, Ronald2009-112010-02-16T19:23:05ZNO_RESTRICTION2010-02-16T19:23:05Z2010-02-16T19:23:05ZThesishttp://hdl.handle.net/1807/18973en_ca
collection NDLTD
language en_ca
sources NDLTD
topic UV-H2O2
disinfection
0543
spellingShingle UV-H2O2
disinfection
0543
Pantin, Sophie
Impacts of UV-H2O2 Treatment for Taste and Odour Control on Secondary Disinfection
description The Cornwall Water Purification Plant collaborated with the University of Toronto to monitor UV-H2O2 treatment performance. This study includes a review of engineering and operational aspects of UV-H2O2 implementation. A number of operational challenges were experienced with retrofitting UV-H2O2 into the existing treatment plant, and an overview of the challenges and solutions faced at Cornwall is given. The project also includes a thorough water quality analysis. Taste and odour (T&O) events have been monitored for three years and the efficiency of UV-H2O2 on T&O removal is reported. Furthermore, little is known about any potential side effects of the treatment on downstream processes, especially secondary disinfection. The impact of UV-H2O2 on natural organic matter alterations, chlorine stability and disinfection by-product formation is reported using results from full-scale water quality monitoring campaigns at Cornwall, combined with laboratory experiments.
author2 Hofmann, Ronald
author_facet Hofmann, Ronald
Pantin, Sophie
author Pantin, Sophie
author_sort Pantin, Sophie
title Impacts of UV-H2O2 Treatment for Taste and Odour Control on Secondary Disinfection
title_short Impacts of UV-H2O2 Treatment for Taste and Odour Control on Secondary Disinfection
title_full Impacts of UV-H2O2 Treatment for Taste and Odour Control on Secondary Disinfection
title_fullStr Impacts of UV-H2O2 Treatment for Taste and Odour Control on Secondary Disinfection
title_full_unstemmed Impacts of UV-H2O2 Treatment for Taste and Odour Control on Secondary Disinfection
title_sort impacts of uv-h2o2 treatment for taste and odour control on secondary disinfection
publishDate 2009
url http://hdl.handle.net/1807/18973
work_keys_str_mv AT pantinsophie impactsofuvh2o2treatmentfortasteandodourcontrolonsecondarydisinfection
_version_ 1716611935220269056