Contribution to the assessment of shelter-in-place effectiveness as a community protection measure in the event of a toxic gas release
En les darreres dècades el nombre d'accidents ocurreguts en la industria química i durant el transport de mercaderies perilloses ha augmentat substancialment, registrant-se en la seva majoria en zones densament poblades. Els núvols de gasos tòxics solen originar-se en aquests accidents i malgra...
Main Author: | |
---|---|
Other Authors: | |
Format: | Doctoral Thesis |
Language: | English |
Published: |
Universitat Politècnica de Catalunya
2010
|
Subjects: | |
Online Access: | http://hdl.handle.net/10803/6485 http://nbn-resolving.de/urn:isbn:9788469420461 |
id |
ndltd-TDX_UPC-oai-www.tdx.cat-10803-6485 |
---|---|
record_format |
oai_dc |
collection |
NDLTD |
language |
English |
format |
Doctoral Thesis |
sources |
NDLTD |
topic |
community protection shelter in place toxic release accidentes industriales viviendas tasa de renovación de aire protección a la población confinamiento gases tóxicos air exchange rate buildings industrial accidents 66 |
spellingShingle |
community protection shelter in place toxic release accidentes industriales viviendas tasa de renovación de aire protección a la población confinamiento gases tóxicos air exchange rate buildings industrial accidents 66 Montoya Rodríguez, María Isabel Contribution to the assessment of shelter-in-place effectiveness as a community protection measure in the event of a toxic gas release |
description |
En les darreres dècades el nombre d'accidents ocurreguts en la industria química i durant el transport de mercaderies perilloses ha augmentat substancialment, registrant-se en la seva majoria en zones densament poblades. Els núvols de gasos tòxics solen originar-se en aquests accidents i malgrat que són menys probables que altres tipus d'accidents, poden afectar grans extensions i contaminar zones poblades, provocant greus conseqüències. Això comporta un gran repte per a les autoritats civils, que han d'avaluar i decidir l'àrea que cal evacuar i l'àrea en la que s'ha d'implementar el confinament com a mesura de protecció. L'avaluació de l'efectivitat del confinament comprèn tres etapes fonamentals: el càlcul de la dispersió exterior, el càlcul de la concentració interior en funció de la concentració exterior i l'avaluació dels efectes adversos per a la salut. Aquesta tesi s'enfoca principalment en l'estudi de la segona etapa, la qual és funció de la taxa d'infiltració d'aire en les edificacions.Inicialment es va realitzar una extensa revisió bibliogràfica sobre les tres etapes, fent èmfasi en la cerca de models pel càlcul de la concentració interior, la taxa d'infiltració y l'hermeticitat de les vivendes. Posteriorment, a través d'una anàlisi de sensibilitat es trobà que la taxa de renovació d'aire té una gran influencia sobre l'efectivitat del confinament i, a més, atès que aquesta varia per cada edificació, el coneixement de la seva distribució en una població és necessari per a una avaluació adequada de l'efectivitat del confinament, ja que suposar-la constant per a totes les edificacions pot comportar sobreestimacions o subestimacions del radi d'evacuació. Per tant, amb la finalitat d'obtenir una aproximació de la distribució de l'hermeticitat, es va aplicar el model desenvolupat pel Lawrence Berkeley National Laboratory (LBNL), que prové de dades de vivendes nord-americanes, a les vivendes catalanes. De tota manera, els resultats obtinguts es trobaven esbiaixats a les zones climàtiques, essent les prediccions per a vivendes ubicades en zones seques més hermètiques que en zones humides. En el cas de Catalunya, on les tècniques constructives no varien significativament d'una zona a una altra i la majoria de vivendes estan construïdes a base de materials pesats, no és d'esperar una diferència tan marcada com la predita pel model del LBNL. Per tant, es va decidir desenvolupar un model per a les vivendes catalanes utilitzant la base de dades de taxes d'infiltració de vivendes unifamiliars del CETE de Lyon, ja que aquestes vivendes tenen més similitud amb les vivendes catalanes que no pas les nord-americanes.El model desenvolupat, denominat UPC-CETE, permet estimar l'hermeticitat de les vivendes unifamiliars en funció de l'àrea, el número de pisos, l'edat i el tipus d'estructura constructiva: lleugera o pesada. Els valors d'hermeticitat predits amb aquest model foren menors que els obtinguts amb el model del LNBL, tal com s'esperava. Finalment, per tal de validar i millorar el model desenvolupat, es van realitzar mesures de la taxa de renovació d'aire en diverses vivendes de Catalunya i també en habitacions prèviament condicionades per ser utilitzades com a refugi, per tal d'avaluar la reducció guanyada sobre la taxa de renovació de tota la vivenda. Com a mitjana, s'obtingueren reduccions d'un 35% i es trobà que les reduccions més grans tenien lloc en vivendes antigues, amb àrees petites d'una o dues plantes. El model UPC-CETE millorat a partir dels resultats obtinguts en les proves experimentals, s'incorporà a la metodologia per avaluar l'efectivitat del confinament en l'etapa d'estimació de la taxa de renovació d'aire, evitant l'ús d'un valor constant per a totes les vivendes i promovent així l'ús d'una distribució d'aquest paràmetre per secció censal afectada dins la població. === During the last decades the number of accidents in chemical industries and during transportation of hazardous substances has significantly increased, with most of them occurring in highly populated areas. One of the possible accidents is a toxic gas cloud, which although less common than other major hazards could affect larger areas reaching populated zones and producing more severe consequences. This implies then, a great challenge to emergency managers who must plan and decide the areas where protection measures should be implemented: shelter in place and/or evacuation. The assessment of the effectiveness of shelter in place is subjected to three main stages: the calculation of the outdoor gas dispersion, the estimation of indoor concentration from outdoor concentration and the evaluation of human vulnerability. This thesis is mainly focused on the study of the second stage which is primarily a function of buildings leakage.Initially we performed a bibliographic survey with special interest on the models to estimate indoor concentration from outdoor concentration, airtightness of dwellings and ventilation models. Then, through a sensitivity analysis, we found that the air exchange rate has a great influence on the effectiveness of shelter in place. Moreover, since this parameter is different for each building, the knowledge of the distribution of this variable in the affected population would lead to a more accurate assessment of the effectiveness of shelter in place, because if we assume it as a fix value, constant for all buildings, over or underestimations of the evacuation radius may occur. Therefore, with the aim of making an estimation of the airtightness distribution in Catalunya, we applied the model developed by the Lawrence Berkeley National Laboratory (LBNL), a model based on data from North American dwellings, to Catalan dwellings. The results obtained were influenced by climate zones, due to the coefficients of the model, being more airtight the predictions for dwellings located in dry climates than for dwellings in humid zones. In the case of Catalunya, where constructions techniques do not differ significantly from one zone to another and most of the dwellings consist of a heavy structure, a difference such as that predicted by the model of the LBNL is not expected. Consequently, we decided to develop a model for Catalan dwellings using the air leakage database from the CETE de Lyon, since French dwellings are more likely to Catalan dwellings than US dwellings. The model developed, named the UPC-CETE model, predicts the airtightness of single-family dwellings as a function of the floor area, the age, the number of stories and the structure type: light or heavy. The airtihgtness values predicted with this model were smaller than those predicted with the model of the LBNL, as was expected. Finally, in order to validate and improve the model developed we carried out a series of trials to measure the air exchange rate in some Catalan dwellings. Measurements in sealed rooms were also performed with the aim of assessing the reduction gained on the air exchange rate with regards to the air exchange rate of the whole dwelling. On average, we obtained reductions of 35% and found that larger reductions belonged to old dwellings with small floor areas and 1 or 2 stories. The improved model was incorporated on the methodology to assess shelter in place effectiveness on the stage concerning the estimation of the air exchange rate of the dwellings located on the affected zone; therefore, the assumption of a constant value is avoided. These measurements and the model constitute therefore the first proposal for estimating the airtightness distribution of single-family dwellings that could be used by Catalan authorities for emergency response planning. |
author2 |
Planas Cuchi, Eulàlia |
author_facet |
Planas Cuchi, Eulàlia Montoya Rodríguez, María Isabel |
author |
Montoya Rodríguez, María Isabel |
author_sort |
Montoya Rodríguez, María Isabel |
title |
Contribution to the assessment of shelter-in-place effectiveness as a community protection measure in the event of a toxic gas release |
title_short |
Contribution to the assessment of shelter-in-place effectiveness as a community protection measure in the event of a toxic gas release |
title_full |
Contribution to the assessment of shelter-in-place effectiveness as a community protection measure in the event of a toxic gas release |
title_fullStr |
Contribution to the assessment of shelter-in-place effectiveness as a community protection measure in the event of a toxic gas release |
title_full_unstemmed |
Contribution to the assessment of shelter-in-place effectiveness as a community protection measure in the event of a toxic gas release |
title_sort |
contribution to the assessment of shelter-in-place effectiveness as a community protection measure in the event of a toxic gas release |
publisher |
Universitat Politècnica de Catalunya |
publishDate |
2010 |
url |
http://hdl.handle.net/10803/6485 http://nbn-resolving.de/urn:isbn:9788469420461 |
work_keys_str_mv |
AT montoyarodriguezmariaisabel contributiontotheassessmentofshelterinplaceeffectivenessasacommunityprotectionmeasureintheeventofatoxicgasrelease |
_version_ |
1716592396962103296 |
spelling |
ndltd-TDX_UPC-oai-www.tdx.cat-10803-64852013-07-11T03:39:45ZContribution to the assessment of shelter-in-place effectiveness as a community protection measure in the event of a toxic gas releaseMontoya Rodríguez, María Isabelcommunity protectionshelter in placetoxic releaseaccidentes industrialesviviendastasa de renovación de aireprotección a la poblaciónconfinamientogases tóxicosair exchange ratebuildingsindustrial accidents66En les darreres dècades el nombre d'accidents ocurreguts en la industria química i durant el transport de mercaderies perilloses ha augmentat substancialment, registrant-se en la seva majoria en zones densament poblades. Els núvols de gasos tòxics solen originar-se en aquests accidents i malgrat que són menys probables que altres tipus d'accidents, poden afectar grans extensions i contaminar zones poblades, provocant greus conseqüències. Això comporta un gran repte per a les autoritats civils, que han d'avaluar i decidir l'àrea que cal evacuar i l'àrea en la que s'ha d'implementar el confinament com a mesura de protecció. L'avaluació de l'efectivitat del confinament comprèn tres etapes fonamentals: el càlcul de la dispersió exterior, el càlcul de la concentració interior en funció de la concentració exterior i l'avaluació dels efectes adversos per a la salut. Aquesta tesi s'enfoca principalment en l'estudi de la segona etapa, la qual és funció de la taxa d'infiltració d'aire en les edificacions.Inicialment es va realitzar una extensa revisió bibliogràfica sobre les tres etapes, fent èmfasi en la cerca de models pel càlcul de la concentració interior, la taxa d'infiltració y l'hermeticitat de les vivendes. Posteriorment, a través d'una anàlisi de sensibilitat es trobà que la taxa de renovació d'aire té una gran influencia sobre l'efectivitat del confinament i, a més, atès que aquesta varia per cada edificació, el coneixement de la seva distribució en una població és necessari per a una avaluació adequada de l'efectivitat del confinament, ja que suposar-la constant per a totes les edificacions pot comportar sobreestimacions o subestimacions del radi d'evacuació. Per tant, amb la finalitat d'obtenir una aproximació de la distribució de l'hermeticitat, es va aplicar el model desenvolupat pel Lawrence Berkeley National Laboratory (LBNL), que prové de dades de vivendes nord-americanes, a les vivendes catalanes. De tota manera, els resultats obtinguts es trobaven esbiaixats a les zones climàtiques, essent les prediccions per a vivendes ubicades en zones seques més hermètiques que en zones humides. En el cas de Catalunya, on les tècniques constructives no varien significativament d'una zona a una altra i la majoria de vivendes estan construïdes a base de materials pesats, no és d'esperar una diferència tan marcada com la predita pel model del LBNL. Per tant, es va decidir desenvolupar un model per a les vivendes catalanes utilitzant la base de dades de taxes d'infiltració de vivendes unifamiliars del CETE de Lyon, ja que aquestes vivendes tenen més similitud amb les vivendes catalanes que no pas les nord-americanes.El model desenvolupat, denominat UPC-CETE, permet estimar l'hermeticitat de les vivendes unifamiliars en funció de l'àrea, el número de pisos, l'edat i el tipus d'estructura constructiva: lleugera o pesada. Els valors d'hermeticitat predits amb aquest model foren menors que els obtinguts amb el model del LNBL, tal com s'esperava. Finalment, per tal de validar i millorar el model desenvolupat, es van realitzar mesures de la taxa de renovació d'aire en diverses vivendes de Catalunya i també en habitacions prèviament condicionades per ser utilitzades com a refugi, per tal d'avaluar la reducció guanyada sobre la taxa de renovació de tota la vivenda. Com a mitjana, s'obtingueren reduccions d'un 35% i es trobà que les reduccions més grans tenien lloc en vivendes antigues, amb àrees petites d'una o dues plantes. El model UPC-CETE millorat a partir dels resultats obtinguts en les proves experimentals, s'incorporà a la metodologia per avaluar l'efectivitat del confinament en l'etapa d'estimació de la taxa de renovació d'aire, evitant l'ús d'un valor constant per a totes les vivendes i promovent així l'ús d'una distribució d'aquest paràmetre per secció censal afectada dins la població.During the last decades the number of accidents in chemical industries and during transportation of hazardous substances has significantly increased, with most of them occurring in highly populated areas. One of the possible accidents is a toxic gas cloud, which although less common than other major hazards could affect larger areas reaching populated zones and producing more severe consequences. This implies then, a great challenge to emergency managers who must plan and decide the areas where protection measures should be implemented: shelter in place and/or evacuation. The assessment of the effectiveness of shelter in place is subjected to three main stages: the calculation of the outdoor gas dispersion, the estimation of indoor concentration from outdoor concentration and the evaluation of human vulnerability. This thesis is mainly focused on the study of the second stage which is primarily a function of buildings leakage.Initially we performed a bibliographic survey with special interest on the models to estimate indoor concentration from outdoor concentration, airtightness of dwellings and ventilation models. Then, through a sensitivity analysis, we found that the air exchange rate has a great influence on the effectiveness of shelter in place. Moreover, since this parameter is different for each building, the knowledge of the distribution of this variable in the affected population would lead to a more accurate assessment of the effectiveness of shelter in place, because if we assume it as a fix value, constant for all buildings, over or underestimations of the evacuation radius may occur. Therefore, with the aim of making an estimation of the airtightness distribution in Catalunya, we applied the model developed by the Lawrence Berkeley National Laboratory (LBNL), a model based on data from North American dwellings, to Catalan dwellings. The results obtained were influenced by climate zones, due to the coefficients of the model, being more airtight the predictions for dwellings located in dry climates than for dwellings in humid zones. In the case of Catalunya, where constructions techniques do not differ significantly from one zone to another and most of the dwellings consist of a heavy structure, a difference such as that predicted by the model of the LBNL is not expected. Consequently, we decided to develop a model for Catalan dwellings using the air leakage database from the CETE de Lyon, since French dwellings are more likely to Catalan dwellings than US dwellings. The model developed, named the UPC-CETE model, predicts the airtightness of single-family dwellings as a function of the floor area, the age, the number of stories and the structure type: light or heavy. The airtihgtness values predicted with this model were smaller than those predicted with the model of the LBNL, as was expected. Finally, in order to validate and improve the model developed we carried out a series of trials to measure the air exchange rate in some Catalan dwellings. Measurements in sealed rooms were also performed with the aim of assessing the reduction gained on the air exchange rate with regards to the air exchange rate of the whole dwelling. On average, we obtained reductions of 35% and found that larger reductions belonged to old dwellings with small floor areas and 1 or 2 stories. The improved model was incorporated on the methodology to assess shelter in place effectiveness on the stage concerning the estimation of the air exchange rate of the dwellings located on the affected zone; therefore, the assumption of a constant value is avoided. These measurements and the model constitute therefore the first proposal for estimating the airtightness distribution of single-family dwellings that could be used by Catalan authorities for emergency response planning.Universitat Politècnica de CatalunyaPlanas Cuchi, EulàliaUniversitat Politècnica de Catalunya. Departament d'Enginyeria Química2010-11-26info:eu-repo/semantics/doctoralThesisinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/10803/6485urn:isbn:9788469420461TDX (Tesis Doctorals en Xarxa)enginfo:eu-repo/semantics/openAccessADVERTIMENT. L'accés als continguts d'aquesta tesi doctoral i la seva utilització ha de respectar els drets de la persona autora. Pot ser utilitzada per a consulta o estudi personal, així com en activitats o materials d'investigació i docència en els termes establerts a l'art. 32 del Text Refós de la Llei de Propietat Intel·lectual (RDL 1/1996). Per altres utilitzacions es requereix l'autorització prèvia i expressa de la persona autora. En qualsevol cas, en la utilització dels seus continguts caldrà indicar de forma clara el nom i cognoms de la persona autora i el títol de la tesi doctoral. No s'autoritza la seva reproducció o altres formes d'explotació efectuades amb finalitats de lucre ni la seva comunicació pública des d'un lloc aliè al servei TDX. Tampoc s'autoritza la presentació del seu contingut en una finestra o marc aliè a TDX (framing). Aquesta reserva de drets afecta tant als continguts de la tesi com als seus resums i índexs. |