Comparison of Bacterial and Viral Reduction across Different Wastewater Treatment Processes
<p> Today billions of people live without access to basic sanitation facilities, and thousands die every week due to diseases caused by fecal contamination associated with improper sanitation. It has thus become crucial for decision makers to have access to relevant and sufficient data to impl...
Main Author: | |
---|---|
Language: | EN |
Published: |
University of South Florida
2019
|
Subjects: | |
Online Access: | http://pqdtopen.proquest.com/#viewpdf?dispub=10977800 |
id |
ndltd-PROQUEST-oai-pqdtoai.proquest.com-10977800 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-PROQUEST-oai-pqdtoai.proquest.com-109778002019-01-18T04:23:57Z Comparison of Bacterial and Viral Reduction across Different Wastewater Treatment Processes Vagadia, Aayushi R. Water resources management|Environmental engineering <p> Today billions of people live without access to basic sanitation facilities, and thousands die every week due to diseases caused by fecal contamination associated with improper sanitation. It has thus become crucial for decision makers to have access to relevant and sufficient data to implement appropriate solutions to these problems. The Global Water Pathogen Project <u> http://www.waterpathogens.org/</u> is dedicated to providing an up-to-date source of data on pathogen reduction associated with different sanitation technologies that are important if the world is to achieve the Sustainable Development Goals (SDGs) related to health and sanitation provision. In this research, a subset of the Global Water Pathogen Project (GWPP) data is used to access the reduction of bacteria and viruses across different mechanical and natural sanitation technologies. The order of expected removal for bacteria during wastewater treatment was reported as highest for a membrane bioreactor (4.4 log10), waste stabilization pond (2.3 log10), conventional activated sludge (1.43 log10), anaerobic anoxic oxic activated sludge (1.9 log10), trickling filter (1.16 log10), and upflow anaerobic sludge blanket reactor (1.2 log10). </p><p> Furthermore, the order of expected removal for viruses was reported as highest for a membrane bioreactor (3.3 log10), conventional activated sludge (1.84 log10), anaerobic anoxic oxic activated sludge (1.67 log10), waste stabilization pond (1 log10), upflow anaerobic sludge blanket reactor (0.3 log10) and trickling filter (0.29 log10). It was found that hydraulic retention time (HRT) had a statistically significant relation to the reduction of bacteria in an anaerobic, anoxic oxic treatment system. Similarly, a significant relation was found between the number of waste stabilization ponds in series and the expected reduction of bacteria. HRT was also found to be a significant factor in virus reduction in waste stabilization ponds. Additionally, it was observed that waste stabilization ponds, trickling filters, and UASB reactors could obtain a greater reduction in bacteria (5–7 log10) when combined with additional treatment (e.g., chemical disinfection or use of maturation ponds). Also, mechanized systems, such as activated sludge systems and membrane bioreactors, obtained a greater reduction (2–3 log10) of viruses when compared to a natural system. It was concluded that the selection of the best suitable technology for pathogen reduction depends on environmental, design, and operational factors as well as considering the performance of specific wastewater treatment systems individually as well as when combined with other treatment technologies that may provide added removal of microbial constituents. </p><p> University of South Florida 2019-01-17 00:00:00.0 thesis http://pqdtopen.proquest.com/#viewpdf?dispub=10977800 EN |
collection |
NDLTD |
language |
EN |
sources |
NDLTD |
topic |
Water resources management|Environmental engineering |
spellingShingle |
Water resources management|Environmental engineering Vagadia, Aayushi R. Comparison of Bacterial and Viral Reduction across Different Wastewater Treatment Processes |
description |
<p> Today billions of people live without access to basic sanitation facilities, and thousands die every week due to diseases caused by fecal contamination associated with improper sanitation. It has thus become crucial for decision makers to have access to relevant and sufficient data to implement appropriate solutions to these problems. The Global Water Pathogen Project <u> http://www.waterpathogens.org/</u> is dedicated to providing an up-to-date source of data on pathogen reduction associated with different sanitation technologies that are important if the world is to achieve the Sustainable Development Goals (SDGs) related to health and sanitation provision. In this research, a subset of the Global Water Pathogen Project (GWPP) data is used to access the reduction of bacteria and viruses across different mechanical and natural sanitation technologies. The order of expected removal for bacteria during wastewater treatment was reported as highest for a membrane bioreactor (4.4 log10), waste stabilization pond (2.3 log10), conventional activated sludge (1.43 log10), anaerobic anoxic oxic activated sludge (1.9 log10), trickling filter (1.16 log10), and upflow anaerobic sludge blanket reactor (1.2 log10). </p><p> Furthermore, the order of expected removal for viruses was reported as highest for a membrane bioreactor (3.3 log10), conventional activated sludge (1.84 log10), anaerobic anoxic oxic activated sludge (1.67 log10), waste stabilization pond (1 log10), upflow anaerobic sludge blanket reactor (0.3 log10) and trickling filter (0.29 log10). It was found that hydraulic retention time (HRT) had a statistically significant relation to the reduction of bacteria in an anaerobic, anoxic oxic treatment system. Similarly, a significant relation was found between the number of waste stabilization ponds in series and the expected reduction of bacteria. HRT was also found to be a significant factor in virus reduction in waste stabilization ponds. Additionally, it was observed that waste stabilization ponds, trickling filters, and UASB reactors could obtain a greater reduction in bacteria (5–7 log10) when combined with additional treatment (e.g., chemical disinfection or use of maturation ponds). Also, mechanized systems, such as activated sludge systems and membrane bioreactors, obtained a greater reduction (2–3 log10) of viruses when compared to a natural system. It was concluded that the selection of the best suitable technology for pathogen reduction depends on environmental, design, and operational factors as well as considering the performance of specific wastewater treatment systems individually as well as when combined with other treatment technologies that may provide added removal of microbial constituents. </p><p> |
author |
Vagadia, Aayushi R. |
author_facet |
Vagadia, Aayushi R. |
author_sort |
Vagadia, Aayushi R. |
title |
Comparison of Bacterial and Viral Reduction across Different Wastewater Treatment Processes |
title_short |
Comparison of Bacterial and Viral Reduction across Different Wastewater Treatment Processes |
title_full |
Comparison of Bacterial and Viral Reduction across Different Wastewater Treatment Processes |
title_fullStr |
Comparison of Bacterial and Viral Reduction across Different Wastewater Treatment Processes |
title_full_unstemmed |
Comparison of Bacterial and Viral Reduction across Different Wastewater Treatment Processes |
title_sort |
comparison of bacterial and viral reduction across different wastewater treatment processes |
publisher |
University of South Florida |
publishDate |
2019 |
url |
http://pqdtopen.proquest.com/#viewpdf?dispub=10977800 |
work_keys_str_mv |
AT vagadiaaayushir comparisonofbacterialandviralreductionacrossdifferentwastewatertreatmentprocesses |
_version_ |
1718814019950739456 |