Hyperoxia Avoidance| A Comparison of Prehospital Oxygen Initiated at High Flow versus Titration to Target Range; a Retrospective Cohort Analysis

<p> <i>Problem:</i> Exposure to high flow oxygen for even short periods of time has been independently linked to increased risk of poor patient outcomes. Evidence supports hypothesis that high flow oxygen may do more harm than good. Cognitive link between hyperoxia and related risk...

Full description

Bibliographic Details
Main Author: McCluskey, Samantha D.
Language:EN
Published: Brandman University 2017
Subjects:
Online Access:http://pqdtopen.proquest.com/#viewpdf?dispub=10641492
id ndltd-PROQUEST-oai-pqdtoai.proquest.com-10641492
record_format oai_dc
spelling ndltd-PROQUEST-oai-pqdtoai.proquest.com-106414922017-12-07T16:10:54Z Hyperoxia Avoidance| A Comparison of Prehospital Oxygen Initiated at High Flow versus Titration to Target Range; a Retrospective Cohort Analysis McCluskey, Samantha D. Nursing <p> <i>Problem:</i> Exposure to high flow oxygen for even short periods of time has been independently linked to increased risk of poor patient outcomes. Evidence supports hypothesis that high flow oxygen may do more harm than good. Cognitive link between hyperoxia and related risk is deficient among prehospital providers. Implementation of hyperoxia avoidance education and evidence based updates to Mesa County, Colorado EMS protocol are predicted to improve provider comprehension and compliance, as well as, reduce patient risk for harm. <i>Purpose:</i> The purpose of this study is to evaluate whether informal introduction to hyperoxia avoidance presented to EMS providers in August 2013 resulted in greater number of patients whose prehospital oxygen was titrated to evidence based range versus high flow. The null hypothesis projects there is no difference between pre-and post-group analysis. <i>Methods:</i> A retrospective review of prehospital patient records was performed utilizing comparative data to analyze difference between independent groups in application of evidence based protocol, number of patients titrated to > 96 percent SpO<sub>2</sub>, and mean of highest recorded SpO<sub>2</sub>. <i>Results:</i> Analysis resulted no statistically significant difference between pre-and post-groups for initiation of evidence based oxygen guidelines, (p = .0697). Although SpO<sub>2</sub> > 96 percent was common in both groups, the post group resulted a reduction in patients titrated to hyperoxia, (p = .024). Sample population mean of high recorded SpO<sub>2</sub> was 97.3 percent with mean difference between groups of 0.5 percent, (p &lt; 0.05). <i>Conclusion:</i> Study outcomes substantiate need for hyperoxia focused education within Mesa County Emergency Medical Services, as well as, indication of protocol generalizability. This manuscript will comprehensively discuss identified problem, study protocol, implication for advanced nursing practice, and areas of future study. </p><p> Brandman University 2017-12-01 00:00:00.0 thesis http://pqdtopen.proquest.com/#viewpdf?dispub=10641492 EN
collection NDLTD
language EN
sources NDLTD
topic Nursing
spellingShingle Nursing
McCluskey, Samantha D.
Hyperoxia Avoidance| A Comparison of Prehospital Oxygen Initiated at High Flow versus Titration to Target Range; a Retrospective Cohort Analysis
description <p> <i>Problem:</i> Exposure to high flow oxygen for even short periods of time has been independently linked to increased risk of poor patient outcomes. Evidence supports hypothesis that high flow oxygen may do more harm than good. Cognitive link between hyperoxia and related risk is deficient among prehospital providers. Implementation of hyperoxia avoidance education and evidence based updates to Mesa County, Colorado EMS protocol are predicted to improve provider comprehension and compliance, as well as, reduce patient risk for harm. <i>Purpose:</i> The purpose of this study is to evaluate whether informal introduction to hyperoxia avoidance presented to EMS providers in August 2013 resulted in greater number of patients whose prehospital oxygen was titrated to evidence based range versus high flow. The null hypothesis projects there is no difference between pre-and post-group analysis. <i>Methods:</i> A retrospective review of prehospital patient records was performed utilizing comparative data to analyze difference between independent groups in application of evidence based protocol, number of patients titrated to > 96 percent SpO<sub>2</sub>, and mean of highest recorded SpO<sub>2</sub>. <i>Results:</i> Analysis resulted no statistically significant difference between pre-and post-groups for initiation of evidence based oxygen guidelines, (p = .0697). Although SpO<sub>2</sub> > 96 percent was common in both groups, the post group resulted a reduction in patients titrated to hyperoxia, (p = .024). Sample population mean of high recorded SpO<sub>2</sub> was 97.3 percent with mean difference between groups of 0.5 percent, (p &lt; 0.05). <i>Conclusion:</i> Study outcomes substantiate need for hyperoxia focused education within Mesa County Emergency Medical Services, as well as, indication of protocol generalizability. This manuscript will comprehensively discuss identified problem, study protocol, implication for advanced nursing practice, and areas of future study. </p><p>
author McCluskey, Samantha D.
author_facet McCluskey, Samantha D.
author_sort McCluskey, Samantha D.
title Hyperoxia Avoidance| A Comparison of Prehospital Oxygen Initiated at High Flow versus Titration to Target Range; a Retrospective Cohort Analysis
title_short Hyperoxia Avoidance| A Comparison of Prehospital Oxygen Initiated at High Flow versus Titration to Target Range; a Retrospective Cohort Analysis
title_full Hyperoxia Avoidance| A Comparison of Prehospital Oxygen Initiated at High Flow versus Titration to Target Range; a Retrospective Cohort Analysis
title_fullStr Hyperoxia Avoidance| A Comparison of Prehospital Oxygen Initiated at High Flow versus Titration to Target Range; a Retrospective Cohort Analysis
title_full_unstemmed Hyperoxia Avoidance| A Comparison of Prehospital Oxygen Initiated at High Flow versus Titration to Target Range; a Retrospective Cohort Analysis
title_sort hyperoxia avoidance| a comparison of prehospital oxygen initiated at high flow versus titration to target range; a retrospective cohort analysis
publisher Brandman University
publishDate 2017
url http://pqdtopen.proquest.com/#viewpdf?dispub=10641492
work_keys_str_mv AT mccluskeysamanthad hyperoxiaavoidanceacomparisonofprehospitaloxygeninitiatedathighflowversustitrationtotargetrangearetrospectivecohortanalysis
_version_ 1718563332981522432