Efficacy of a Multi-Channel Array Coil for Pediatric Cardiac Magnetic Resonance Imaging
Main Author: | |
---|---|
Language: | English |
Published: |
University of Akron / OhioLINK
2008
|
Subjects: | |
Online Access: | http://rave.ohiolink.edu/etdc/view?acc_num=akron1226615129 |
id |
ndltd-OhioLink-oai-etd.ohiolink.edu-akron1226615129 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-OhioLink-oai-etd.ohiolink.edu-akron12266151292021-08-03T05:25:36Z Efficacy of a Multi-Channel Array Coil for Pediatric Cardiac Magnetic Resonance Imaging Ravi, Anandh Biomedical Research Engineering Health Care Radiology Scientific Imaging RF coil MRI Cardiac Infant cardiac imaging Radiology Magnetic Resonance Imaging Infant cadiac array Pediatric MR imaging currently uses adult RF coils which reduces the quality of pediatric images considering the large field of view and low signal to noise ratio (SNR). Thus there is a growing need for developing and evaluating specialty coils targeting pediatric patients. The current study focused on the design, development and evaluation of infant cardiac array RF local coil for magnetic resonance imaging of the heart of infant patients. The design criteria were identified and the coil was designed taking into account the safety considerations for the targeted patient population. This study successfully evaluated the performance of the infant cardiac array RF coil based on two most significant MR imaging parameters, SNR and imaging resolution, on a 1.5T commercial MR scanner. The increase in SNR and improvement in the resolution of images using the infant cardiac array over an existing commercially available adult coil was establishedusing different kinds of phantom (7L, 2L, orange and lime) studies. The results revealed that there was an increase of 140% in SNR using infant cardiac array compared to the commercially available adult coil and the high resolution (<200 microns) images obtained confirmed the efficacy of the infant cardiac array coil. Thus, the infant cardiac array RF coil provides enhanced performance and high quality MR images for infant clinical applications compared to the commercial adult coils. 2008 English text University of Akron / OhioLINK http://rave.ohiolink.edu/etdc/view?acc_num=akron1226615129 http://rave.ohiolink.edu/etdc/view?acc_num=akron1226615129 unrestricted This thesis or dissertation is protected by copyright: all rights reserved. It may not be copied or redistributed beyond the terms of applicable copyright laws. |
collection |
NDLTD |
language |
English |
sources |
NDLTD |
topic |
Biomedical Research Engineering Health Care Radiology Scientific Imaging RF coil MRI Cardiac Infant cardiac imaging Radiology Magnetic Resonance Imaging Infant cadiac array |
spellingShingle |
Biomedical Research Engineering Health Care Radiology Scientific Imaging RF coil MRI Cardiac Infant cardiac imaging Radiology Magnetic Resonance Imaging Infant cadiac array Ravi, Anandh Efficacy of a Multi-Channel Array Coil for Pediatric Cardiac Magnetic Resonance Imaging |
author |
Ravi, Anandh |
author_facet |
Ravi, Anandh |
author_sort |
Ravi, Anandh |
title |
Efficacy of a Multi-Channel Array Coil for Pediatric Cardiac Magnetic Resonance Imaging |
title_short |
Efficacy of a Multi-Channel Array Coil for Pediatric Cardiac Magnetic Resonance Imaging |
title_full |
Efficacy of a Multi-Channel Array Coil for Pediatric Cardiac Magnetic Resonance Imaging |
title_fullStr |
Efficacy of a Multi-Channel Array Coil for Pediatric Cardiac Magnetic Resonance Imaging |
title_full_unstemmed |
Efficacy of a Multi-Channel Array Coil for Pediatric Cardiac Magnetic Resonance Imaging |
title_sort |
efficacy of a multi-channel array coil for pediatric cardiac magnetic resonance imaging |
publisher |
University of Akron / OhioLINK |
publishDate |
2008 |
url |
http://rave.ohiolink.edu/etdc/view?acc_num=akron1226615129 |
work_keys_str_mv |
AT ravianandh efficacyofamultichannelarraycoilforpediatriccardiacmagneticresonanceimaging |
_version_ |
1719419974404014080 |