investigation of the relation between sibilant production and somatosensory and auditory acuity

The relation between auditory acuity, somatosensory acuity and the magnitude of produced sibilant contrast was investigated with data from 18 participants. To measure auditory acuity, stimuli from a synthetic sibilant continuum ([s]-[ʃ]) were used in a four-interval, two-alternative forced choice ad...

Full description

Bibliographic Details
Published:
Online Access:http://hdl.handle.net/2047/d20000871
id ndltd-NEU--neu-332281
record_format oai_dc
spelling ndltd-NEU--neu-3322812016-04-25T16:14:53Zinvestigation of the relation between sibilant production and somatosensory and auditory acuityThe relation between auditory acuity, somatosensory acuity and the magnitude of produced sibilant contrast was investigated with data from 18 participants. To measure auditory acuity, stimuli from a synthetic sibilant continuum ([s]-[ʃ]) were used in a four-interval, two-alternative forced choice adaptive-staircase discrimination task. To measure somatosensory acuity, small plastic domes with grooves of different spacing were pressed against each participant’s tongue tip and the participant was asked to identify one of four possible orientations of the grooves. Sibilant contrast magnitudes were estimated from productions of the words “said,” “shed,” “sid,” and “shid.” Multiple linear regression revealed a significant relation indicating that a combination of somatosensory and auditory acuity measures predicts produced acoustic contrast. When the participants were divided into high- and low-acuity groups based on their median somatosensory and auditory acuity measures, separate ANOVA analyses with sibilant contrast as the dependent variable yielded a significant main effect for each acuity group. These results provide evidence that sibilant productions have auditory as well as somatosensory goals and are consistent with prior results and the theoretical framework underlying the DIVA model of speech production.http://hdl.handle.net/2047/d20000871
collection NDLTD
sources NDLTD
description The relation between auditory acuity, somatosensory acuity and the magnitude of produced sibilant contrast was investigated with data from 18 participants. To measure auditory acuity, stimuli from a synthetic sibilant continuum ([s]-[ʃ]) were used in a four-interval, two-alternative forced choice adaptive-staircase discrimination task. To measure somatosensory acuity, small plastic domes with grooves of different spacing were pressed against each participant’s tongue tip and the participant was asked to identify one of four possible orientations of the grooves. Sibilant contrast magnitudes were estimated from productions of the words “said,” “shed,” “sid,” and “shid.” Multiple linear regression revealed a significant relation indicating that a combination of somatosensory and auditory acuity measures predicts produced acoustic contrast. When the participants were divided into high- and low-acuity groups based on their median somatosensory and auditory acuity measures, separate ANOVA analyses with sibilant contrast as the dependent variable yielded a significant main effect for each acuity group. These results provide evidence that sibilant productions have auditory as well as somatosensory goals and are consistent with prior results and the theoretical framework underlying the DIVA model of speech production.
title investigation of the relation between sibilant production and somatosensory and auditory acuity
spellingShingle investigation of the relation between sibilant production and somatosensory and auditory acuity
title_short investigation of the relation between sibilant production and somatosensory and auditory acuity
title_full investigation of the relation between sibilant production and somatosensory and auditory acuity
title_fullStr investigation of the relation between sibilant production and somatosensory and auditory acuity
title_full_unstemmed investigation of the relation between sibilant production and somatosensory and auditory acuity
title_sort investigation of the relation between sibilant production and somatosensory and auditory acuity
publishDate
url http://hdl.handle.net/2047/d20000871
_version_ 1718235829525020672