Understanding frequency response of a flexural complaint stage for use in oscillatory orthogonal cutting
Thesis: S.B., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2015. === Cataloged from PDF version of thesis. === Includes bibliographical references (page 49). === Ultramicrotomy is the process of cutting specimens into submicron-thickness slices for subsequent imaging...
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Language: | English |
Published: |
Massachusetts Institute of Technology
2015
|
Subjects: | |
Online Access: | http://hdl.handle.net/1721.1/98952 |
id |
ndltd-MIT-oai-dspace.mit.edu-1721.1-98952 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-MIT-oai-dspace.mit.edu-1721.1-989522019-05-02T16:10:07Z Understanding frequency response of a flexural complaint stage for use in oscillatory orthogonal cutting Barraza, Raul Martin L. Culpepper. Massachusetts Institute of Technology. Department of Mechanical Engineering. Massachusetts Institute of Technology. Department of Mechanical Engineering. Mechanical Engineering. Thesis: S.B., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2015. Cataloged from PDF version of thesis. Includes bibliographical references (page 49). Ultramicrotomy is the process of cutting specimens into submicron-thickness slices for subsequent imaging using a scanning electron microscope (SEM). Ultramicrotomes, devices that employ this process, have incorporated oscillations into this process to reduce the damage done on each slice. Extensive research has been made in trying to identify the appropriate settings: frequency, amplitude of cut, and feed speed, to maximize the reduction of this damage. Currently, however, there exists no research that tries to understand why the introduction of oscillations provides such a reduction in damage. To understand the mechanics behind oscillatory orthogonal cutting, specifically in ultramicrotomy, the frequency response of a compliant mechanism must be understood. The frequency response of a complaint flexural stage driven by piezoelectric actuator was measured. Using a Linear Variable Differential Transformer (LVDT) and a dynamic signal analyzer via LabView, the frequency response of the stage was measured from 100Hz to 10000Hz. A model was then fitted to the measured response. Using this model, a comparison between a simulated-reference response of the position of the stage to the output response of the model showed that a controller was required to minimize the error in the position of the stage. by Raul Barraza. S.B. 2015-09-29T18:55:08Z 2015-09-29T18:55:08Z 2015 2015 Thesis http://hdl.handle.net/1721.1/98952 921147486 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 49 pages application/pdf Massachusetts Institute of Technology |
collection |
NDLTD |
language |
English |
format |
Others
|
sources |
NDLTD |
topic |
Mechanical Engineering. |
spellingShingle |
Mechanical Engineering. Barraza, Raul Understanding frequency response of a flexural complaint stage for use in oscillatory orthogonal cutting |
description |
Thesis: S.B., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2015. === Cataloged from PDF version of thesis. === Includes bibliographical references (page 49). === Ultramicrotomy is the process of cutting specimens into submicron-thickness slices for subsequent imaging using a scanning electron microscope (SEM). Ultramicrotomes, devices that employ this process, have incorporated oscillations into this process to reduce the damage done on each slice. Extensive research has been made in trying to identify the appropriate settings: frequency, amplitude of cut, and feed speed, to maximize the reduction of this damage. Currently, however, there exists no research that tries to understand why the introduction of oscillations provides such a reduction in damage. To understand the mechanics behind oscillatory orthogonal cutting, specifically in ultramicrotomy, the frequency response of a compliant mechanism must be understood. The frequency response of a complaint flexural stage driven by piezoelectric actuator was measured. Using a Linear Variable Differential Transformer (LVDT) and a dynamic signal analyzer via LabView, the frequency response of the stage was measured from 100Hz to 10000Hz. A model was then fitted to the measured response. Using this model, a comparison between a simulated-reference response of the position of the stage to the output response of the model showed that a controller was required to minimize the error in the position of the stage. === by Raul Barraza. === S.B. |
author2 |
Martin L. Culpepper. |
author_facet |
Martin L. Culpepper. Barraza, Raul |
author |
Barraza, Raul |
author_sort |
Barraza, Raul |
title |
Understanding frequency response of a flexural complaint stage for use in oscillatory orthogonal cutting |
title_short |
Understanding frequency response of a flexural complaint stage for use in oscillatory orthogonal cutting |
title_full |
Understanding frequency response of a flexural complaint stage for use in oscillatory orthogonal cutting |
title_fullStr |
Understanding frequency response of a flexural complaint stage for use in oscillatory orthogonal cutting |
title_full_unstemmed |
Understanding frequency response of a flexural complaint stage for use in oscillatory orthogonal cutting |
title_sort |
understanding frequency response of a flexural complaint stage for use in oscillatory orthogonal cutting |
publisher |
Massachusetts Institute of Technology |
publishDate |
2015 |
url |
http://hdl.handle.net/1721.1/98952 |
work_keys_str_mv |
AT barrazaraul understandingfrequencyresponseofaflexuralcomplaintstageforuseinoscillatoryorthogonalcutting |
_version_ |
1719036139354980352 |