Two-Color interferometry as a fluctuation diagnostic on Alcator C-Mod
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2013. === Cataloged from PDF version of thesis. === Includes bibliographical references (pages 139-147). === The two-color interferometer diagnostic on Alcator C-Mod has been upgraded to measure line-inte...
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Language: | English |
Published: |
Massachusetts Institute of Technology
2013
|
Subjects: | |
Online Access: | http://hdl.handle.net/1721.1/82457 |
id |
ndltd-MIT-oai-dspace.mit.edu-1721.1-82457 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-MIT-oai-dspace.mit.edu-1721.1-824572019-05-02T16:14:55Z Two-Color interferometry as a fluctuation diagnostic on Alcator C-Mod 2-Color interferometry as a fluctuation diagnostic on Alcator C-Mod Kasten, Cale Phillip Anne E. White. Massachusetts Institute of Technology. Department of Nuclear Science and Engineering. Massachusetts Institute of Technology. Department of Nuclear Science and Engineering. Nuclear Science and Engineering. Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2013. Cataloged from PDF version of thesis. Includes bibliographical references (pages 139-147). The two-color interferometer diagnostic on Alcator C-Mod has been upgraded to measure line-integrated electron density fluctuations for turbulence and transport studies. Heterodyne signals from ten vertical-viewing CO2 laser chords are demodulated relative to a local oscillator using high bandwidth analog in-phase/quadrature electronics, replacing lower bandwidth digital fringe counting electronics. The raw outputs of the high bandwidth electronics, which are proportional to the sine and cosine of the interferometric phase shift, are digitized at up to 10 MHz, which is sufficient for fluctuation analysis. Extraction of the measured phase from the sine and cosine signals is now performed entirely in software, providing the line-integrated electron density at high bandwidth. The interferometer design, calibration, and measurement uncertainty is presented. Measurement uncertainties due to nonlinearities in the analog electronics are found to be comparable to the uncertainties of the previous system. The interferometer can now resolve line-integrated electron density fluctuations with major-radial wavenumbers below ... . The new fluctuation measurement capability is used to partially verify the calibration and low-kR wavenumber response of phase-contrast imaging, to aid in gyrokinetic transport model validation research. Agreement between the two diagnostics is demonstrated for broadband fluctuations and the low-kR component of the quasi-coherent mode, improving confidence in the calibration of the phase-contrast imaging system. Both diagnostics observe a series of fluctuations during quasi-steady periods of minority heated I-mode plasmas with strong off-axis electron heating. The observed fluctuations are localized to the plasma core using Doppler shift analysis and data from edge fluctuation diagnostics. Transport analysis shows that the fluctuations do not correlate with enhanced thermal transport, and gyrokinetic linear stability analysis shows that the plasma is stable to drift wave turbulence, ruling out the possibility that the observed fluctuations are destabilized drift wave turbulence. by Cale Phillip Kasten. S.M. 2013-11-18T19:25:37Z 2013-11-18T19:25:37Z 2013 Thesis http://hdl.handle.net/1721.1/82457 863062863 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 147 pages application/pdf Massachusetts Institute of Technology |
collection |
NDLTD |
language |
English |
format |
Others
|
sources |
NDLTD |
topic |
Nuclear Science and Engineering. |
spellingShingle |
Nuclear Science and Engineering. Kasten, Cale Phillip Two-Color interferometry as a fluctuation diagnostic on Alcator C-Mod |
description |
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2013. === Cataloged from PDF version of thesis. === Includes bibliographical references (pages 139-147). === The two-color interferometer diagnostic on Alcator C-Mod has been upgraded to measure line-integrated electron density fluctuations for turbulence and transport studies. Heterodyne signals from ten vertical-viewing CO2 laser chords are demodulated relative to a local oscillator using high bandwidth analog in-phase/quadrature electronics, replacing lower bandwidth digital fringe counting electronics. The raw outputs of the high bandwidth electronics, which are proportional to the sine and cosine of the interferometric phase shift, are digitized at up to 10 MHz, which is sufficient for fluctuation analysis. Extraction of the measured phase from the sine and cosine signals is now performed entirely in software, providing the line-integrated electron density at high bandwidth. The interferometer design, calibration, and measurement uncertainty is presented. Measurement uncertainties due to nonlinearities in the analog electronics are found to be comparable to the uncertainties of the previous system. The interferometer can now resolve line-integrated electron density fluctuations with major-radial wavenumbers below ... . The new fluctuation measurement capability is used to partially verify the calibration and low-kR wavenumber response of phase-contrast imaging, to aid in gyrokinetic transport model validation research. Agreement between the two diagnostics is demonstrated for broadband fluctuations and the low-kR component of the quasi-coherent mode, improving confidence in the calibration of the phase-contrast imaging system. Both diagnostics observe a series of fluctuations during quasi-steady periods of minority heated I-mode plasmas with strong off-axis electron heating. The observed fluctuations are localized to the plasma core using Doppler shift analysis and data from edge fluctuation diagnostics. Transport analysis shows that the fluctuations do not correlate with enhanced thermal transport, and gyrokinetic linear stability analysis shows that the plasma is stable to drift wave turbulence, ruling out the possibility that the observed fluctuations are destabilized drift wave turbulence. === by Cale Phillip Kasten. === S.M. |
author2 |
Anne E. White. |
author_facet |
Anne E. White. Kasten, Cale Phillip |
author |
Kasten, Cale Phillip |
author_sort |
Kasten, Cale Phillip |
title |
Two-Color interferometry as a fluctuation diagnostic on Alcator C-Mod |
title_short |
Two-Color interferometry as a fluctuation diagnostic on Alcator C-Mod |
title_full |
Two-Color interferometry as a fluctuation diagnostic on Alcator C-Mod |
title_fullStr |
Two-Color interferometry as a fluctuation diagnostic on Alcator C-Mod |
title_full_unstemmed |
Two-Color interferometry as a fluctuation diagnostic on Alcator C-Mod |
title_sort |
two-color interferometry as a fluctuation diagnostic on alcator c-mod |
publisher |
Massachusetts Institute of Technology |
publishDate |
2013 |
url |
http://hdl.handle.net/1721.1/82457 |
work_keys_str_mv |
AT kastencalephillip twocolorinterferometryasafluctuationdiagnosticonalcatorcmod AT kastencalephillip 2colorinterferometryasafluctuationdiagnosticonalcatorcmod |
_version_ |
1719037589857501184 |