Shuttling of ions for characterization of a microfabricated ion trap

Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2012. === Cataloged from PDF version of thesis. === Includes bibliographical references (p. 65-67). === In this thesis, I present experimental results demonstrating the characterization of a planar Paul trap. I discuss the theor...

Full description

Bibliographic Details
Main Author: Fisher, Zachary (Zachary Kenneth)
Other Authors: Isaac L. Chuang.
Format: Others
Language:English
Published: Massachusetts Institute of Technology 2013
Subjects:
Online Access:http://hdl.handle.net/1721.1/78510
id ndltd-MIT-oai-dspace.mit.edu-1721.1-78510
record_format oai_dc
spelling ndltd-MIT-oai-dspace.mit.edu-1721.1-785102019-05-02T15:56:13Z Shuttling of ions for characterization of a microfabricated ion trap Fisher, Zachary (Zachary Kenneth) Isaac L. Chuang. Massachusetts Institute of Technology. Department of Physics. Massachusetts Institute of Technology. Department of Physics. Physics. Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2012. Cataloged from PDF version of thesis. Includes bibliographical references (p. 65-67). In this thesis, I present experimental results demonstrating the characterization of a planar Paul trap. I discuss the theory of ion trapping and analyze the voltages required for shuttling. Next, the characteristics of a digital-to-analog converter (DAC) are calibrated, and this instrument is integrated into trapping experiments to test the viability of the analytic model. Combining theory with the capabilities of the DAC, I calculate that the new experimental system is capable of 3 nm-precision control of the ion. Taking advantage of this ion control, I present initial results for a lock-in micromotion detection method which minimizes stray fields around an ⁸⁸Sr+ ion using Fourier analysis on the ion fluorescence to detect resonance at the secular frequencies. This method drives the ion oscillator across resonance using a superimposed radiofrequency electric field, which allows for off-axis field measurements as well as trap characterization. With this method, the secular frequencies of the trap are measured and are observed to fall within 3.50[sigma] of the analytic prediction. by Zachary Fisher. S.B. 2013-04-12T19:31:06Z 2013-04-12T19:31:06Z 2012 2012 Thesis http://hdl.handle.net/1721.1/78510 836796500 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 67 p. application/pdf Massachusetts Institute of Technology
collection NDLTD
language English
format Others
sources NDLTD
topic Physics.
spellingShingle Physics.
Fisher, Zachary (Zachary Kenneth)
Shuttling of ions for characterization of a microfabricated ion trap
description Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2012. === Cataloged from PDF version of thesis. === Includes bibliographical references (p. 65-67). === In this thesis, I present experimental results demonstrating the characterization of a planar Paul trap. I discuss the theory of ion trapping and analyze the voltages required for shuttling. Next, the characteristics of a digital-to-analog converter (DAC) are calibrated, and this instrument is integrated into trapping experiments to test the viability of the analytic model. Combining theory with the capabilities of the DAC, I calculate that the new experimental system is capable of 3 nm-precision control of the ion. Taking advantage of this ion control, I present initial results for a lock-in micromotion detection method which minimizes stray fields around an ⁸⁸Sr+ ion using Fourier analysis on the ion fluorescence to detect resonance at the secular frequencies. This method drives the ion oscillator across resonance using a superimposed radiofrequency electric field, which allows for off-axis field measurements as well as trap characterization. With this method, the secular frequencies of the trap are measured and are observed to fall within 3.50[sigma] of the analytic prediction. === by Zachary Fisher. === S.B.
author2 Isaac L. Chuang.
author_facet Isaac L. Chuang.
Fisher, Zachary (Zachary Kenneth)
author Fisher, Zachary (Zachary Kenneth)
author_sort Fisher, Zachary (Zachary Kenneth)
title Shuttling of ions for characterization of a microfabricated ion trap
title_short Shuttling of ions for characterization of a microfabricated ion trap
title_full Shuttling of ions for characterization of a microfabricated ion trap
title_fullStr Shuttling of ions for characterization of a microfabricated ion trap
title_full_unstemmed Shuttling of ions for characterization of a microfabricated ion trap
title_sort shuttling of ions for characterization of a microfabricated ion trap
publisher Massachusetts Institute of Technology
publishDate 2013
url http://hdl.handle.net/1721.1/78510
work_keys_str_mv AT fisherzacharyzacharykenneth shuttlingofionsforcharacterizationofamicrofabricatediontrap
_version_ 1719031511600070656