Analysis and design of an adjustable bone plate for mandibular fracture fixation

Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011. === Cataloged from PDF version of thesis. === Includes bibliographical references (p. 57-59). === This thesis presents the design, analysis and testing of a bone plate for mandibular fracture fixation. Conve...

Full description

Bibliographic Details
Main Author: Cervantes, Thomas Michael
Other Authors: Alexander H Slocum.
Format: Others
Language:English
Published: Massachusetts Institute of Technology 2012
Subjects:
Online Access:http://hdl.handle.net/1721.1/69508
id ndltd-MIT-oai-dspace.mit.edu-1721.1-69508
record_format oai_dc
spelling ndltd-MIT-oai-dspace.mit.edu-1721.1-695082019-05-02T16:20:17Z Analysis and design of an adjustable bone plate for mandibular fracture fixation Cervantes, Thomas Michael Alexander H Slocum. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Mechanical Engineering. Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011. Cataloged from PDF version of thesis. Includes bibliographical references (p. 57-59). This thesis presents the design, analysis and testing of a bone plate for mandibular fracture fixation. Conventional bone plates are commonly used to set fractures of the mandible in a surgical setting. If proper alignment between the two bone segments is not achieved, then a malocclusion can result; this condition often causes significant discomfort to the patient, and may require costly and risky revision surgery to repair. Current methods of bone plate fixation require a surgeon to visually align the segments of bone, and once the plate has been affixed to the bone, there is little that can be done to adjust alignment of the fracture. The modified bone plate presented here has a deformable mid-section, with the purpose of allowing a surgeon to compensate for mis-alignment observed after the plate has been affixed to the fractured bone. The mechanics of deformation associated with various adjustment mechanisms was explored analytically, numerically, and experimentally. It was found that in order to plastically deform the adjustable section, a force of 358.8 N is required, compared with a predicted value of 351 N obtained using numerical simulations and 487 N using a fixed-fixed beam model with a concentrated central load. In addition to static tests, a dynamic testing jig has been designed with the intent of evaluating in vitro performance of the modified bone plate. Current ASTM and ISO standards for bone plate testing require forces to be applied to the faces of the bone plate, orthogonal to the direction of loading experienced in vivo. This condition is applicable to long bones such as the humerus or femur, however loading conditions of the mandible are significantly different. The testing jig allows for any bone plate of any shape to be fixed such that a force can be applied in order to simulate the normal in vivo loading conditions. This system could be used to further optimize the design of current and future deformable bone plates before they are incorporated into invasive animal or clinical trials. by Thomas Michael Cervantes. S.B. 2012-02-29T18:22:25Z 2012-02-29T18:22:25Z 2011 2011 Thesis http://hdl.handle.net/1721.1/69508 775675639 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 59 p. application/pdf Massachusetts Institute of Technology
collection NDLTD
language English
format Others
sources NDLTD
topic Mechanical Engineering.
spellingShingle Mechanical Engineering.
Cervantes, Thomas Michael
Analysis and design of an adjustable bone plate for mandibular fracture fixation
description Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011. === Cataloged from PDF version of thesis. === Includes bibliographical references (p. 57-59). === This thesis presents the design, analysis and testing of a bone plate for mandibular fracture fixation. Conventional bone plates are commonly used to set fractures of the mandible in a surgical setting. If proper alignment between the two bone segments is not achieved, then a malocclusion can result; this condition often causes significant discomfort to the patient, and may require costly and risky revision surgery to repair. Current methods of bone plate fixation require a surgeon to visually align the segments of bone, and once the plate has been affixed to the bone, there is little that can be done to adjust alignment of the fracture. The modified bone plate presented here has a deformable mid-section, with the purpose of allowing a surgeon to compensate for mis-alignment observed after the plate has been affixed to the fractured bone. The mechanics of deformation associated with various adjustment mechanisms was explored analytically, numerically, and experimentally. It was found that in order to plastically deform the adjustable section, a force of 358.8 N is required, compared with a predicted value of 351 N obtained using numerical simulations and 487 N using a fixed-fixed beam model with a concentrated central load. In addition to static tests, a dynamic testing jig has been designed with the intent of evaluating in vitro performance of the modified bone plate. Current ASTM and ISO standards for bone plate testing require forces to be applied to the faces of the bone plate, orthogonal to the direction of loading experienced in vivo. This condition is applicable to long bones such as the humerus or femur, however loading conditions of the mandible are significantly different. The testing jig allows for any bone plate of any shape to be fixed such that a force can be applied in order to simulate the normal in vivo loading conditions. This system could be used to further optimize the design of current and future deformable bone plates before they are incorporated into invasive animal or clinical trials. === by Thomas Michael Cervantes. === S.B.
author2 Alexander H Slocum.
author_facet Alexander H Slocum.
Cervantes, Thomas Michael
author Cervantes, Thomas Michael
author_sort Cervantes, Thomas Michael
title Analysis and design of an adjustable bone plate for mandibular fracture fixation
title_short Analysis and design of an adjustable bone plate for mandibular fracture fixation
title_full Analysis and design of an adjustable bone plate for mandibular fracture fixation
title_fullStr Analysis and design of an adjustable bone plate for mandibular fracture fixation
title_full_unstemmed Analysis and design of an adjustable bone plate for mandibular fracture fixation
title_sort analysis and design of an adjustable bone plate for mandibular fracture fixation
publisher Massachusetts Institute of Technology
publishDate 2012
url http://hdl.handle.net/1721.1/69508
work_keys_str_mv AT cervantesthomasmichael analysisanddesignofanadjustableboneplateformandibularfracturefixation
_version_ 1719039010332999680