Analysis and design of an adjustable bone plate for mandibular fracture fixation
Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011. === Cataloged from PDF version of thesis. === Includes bibliographical references (p. 57-59). === This thesis presents the design, analysis and testing of a bone plate for mandibular fracture fixation. Conve...
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Language: | English |
Published: |
Massachusetts Institute of Technology
2012
|
Subjects: | |
Online Access: | http://hdl.handle.net/1721.1/69508 |
id |
ndltd-MIT-oai-dspace.mit.edu-1721.1-69508 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-MIT-oai-dspace.mit.edu-1721.1-695082019-05-02T16:20:17Z Analysis and design of an adjustable bone plate for mandibular fracture fixation Cervantes, Thomas Michael Alexander H Slocum. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Mechanical Engineering. Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011. Cataloged from PDF version of thesis. Includes bibliographical references (p. 57-59). This thesis presents the design, analysis and testing of a bone plate for mandibular fracture fixation. Conventional bone plates are commonly used to set fractures of the mandible in a surgical setting. If proper alignment between the two bone segments is not achieved, then a malocclusion can result; this condition often causes significant discomfort to the patient, and may require costly and risky revision surgery to repair. Current methods of bone plate fixation require a surgeon to visually align the segments of bone, and once the plate has been affixed to the bone, there is little that can be done to adjust alignment of the fracture. The modified bone plate presented here has a deformable mid-section, with the purpose of allowing a surgeon to compensate for mis-alignment observed after the plate has been affixed to the fractured bone. The mechanics of deformation associated with various adjustment mechanisms was explored analytically, numerically, and experimentally. It was found that in order to plastically deform the adjustable section, a force of 358.8 N is required, compared with a predicted value of 351 N obtained using numerical simulations and 487 N using a fixed-fixed beam model with a concentrated central load. In addition to static tests, a dynamic testing jig has been designed with the intent of evaluating in vitro performance of the modified bone plate. Current ASTM and ISO standards for bone plate testing require forces to be applied to the faces of the bone plate, orthogonal to the direction of loading experienced in vivo. This condition is applicable to long bones such as the humerus or femur, however loading conditions of the mandible are significantly different. The testing jig allows for any bone plate of any shape to be fixed such that a force can be applied in order to simulate the normal in vivo loading conditions. This system could be used to further optimize the design of current and future deformable bone plates before they are incorporated into invasive animal or clinical trials. by Thomas Michael Cervantes. S.B. 2012-02-29T18:22:25Z 2012-02-29T18:22:25Z 2011 2011 Thesis http://hdl.handle.net/1721.1/69508 775675639 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 59 p. application/pdf Massachusetts Institute of Technology |
collection |
NDLTD |
language |
English |
format |
Others
|
sources |
NDLTD |
topic |
Mechanical Engineering. |
spellingShingle |
Mechanical Engineering. Cervantes, Thomas Michael Analysis and design of an adjustable bone plate for mandibular fracture fixation |
description |
Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011. === Cataloged from PDF version of thesis. === Includes bibliographical references (p. 57-59). === This thesis presents the design, analysis and testing of a bone plate for mandibular fracture fixation. Conventional bone plates are commonly used to set fractures of the mandible in a surgical setting. If proper alignment between the two bone segments is not achieved, then a malocclusion can result; this condition often causes significant discomfort to the patient, and may require costly and risky revision surgery to repair. Current methods of bone plate fixation require a surgeon to visually align the segments of bone, and once the plate has been affixed to the bone, there is little that can be done to adjust alignment of the fracture. The modified bone plate presented here has a deformable mid-section, with the purpose of allowing a surgeon to compensate for mis-alignment observed after the plate has been affixed to the fractured bone. The mechanics of deformation associated with various adjustment mechanisms was explored analytically, numerically, and experimentally. It was found that in order to plastically deform the adjustable section, a force of 358.8 N is required, compared with a predicted value of 351 N obtained using numerical simulations and 487 N using a fixed-fixed beam model with a concentrated central load. In addition to static tests, a dynamic testing jig has been designed with the intent of evaluating in vitro performance of the modified bone plate. Current ASTM and ISO standards for bone plate testing require forces to be applied to the faces of the bone plate, orthogonal to the direction of loading experienced in vivo. This condition is applicable to long bones such as the humerus or femur, however loading conditions of the mandible are significantly different. The testing jig allows for any bone plate of any shape to be fixed such that a force can be applied in order to simulate the normal in vivo loading conditions. This system could be used to further optimize the design of current and future deformable bone plates before they are incorporated into invasive animal or clinical trials. === by Thomas Michael Cervantes. === S.B. |
author2 |
Alexander H Slocum. |
author_facet |
Alexander H Slocum. Cervantes, Thomas Michael |
author |
Cervantes, Thomas Michael |
author_sort |
Cervantes, Thomas Michael |
title |
Analysis and design of an adjustable bone plate for mandibular fracture fixation |
title_short |
Analysis and design of an adjustable bone plate for mandibular fracture fixation |
title_full |
Analysis and design of an adjustable bone plate for mandibular fracture fixation |
title_fullStr |
Analysis and design of an adjustable bone plate for mandibular fracture fixation |
title_full_unstemmed |
Analysis and design of an adjustable bone plate for mandibular fracture fixation |
title_sort |
analysis and design of an adjustable bone plate for mandibular fracture fixation |
publisher |
Massachusetts Institute of Technology |
publishDate |
2012 |
url |
http://hdl.handle.net/1721.1/69508 |
work_keys_str_mv |
AT cervantesthomasmichael analysisanddesignofanadjustableboneplateformandibularfracturefixation |
_version_ |
1719039010332999680 |