Characterization of a pre-curved needle for use in distal tip manipulation mechanism

Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2009. === Cataloged from PDF version of thesis. === Includes bibliographical references (p. 59-61). === The knowledge and technical expertise required for the development of telerobotic systems capable of needle d...

Full description

Bibliographic Details
Main Author: Franklin, Jeremy Contini
Other Authors: Alexander H. Slocum.
Format: Others
Language:English
Published: Massachusetts Institute of Technology 2010
Subjects:
Online Access:http://hdl.handle.net/1721.1/59886
id ndltd-MIT-oai-dspace.mit.edu-1721.1-59886
record_format oai_dc
spelling ndltd-MIT-oai-dspace.mit.edu-1721.1-598862019-05-02T16:21:28Z Characterization of a pre-curved needle for use in distal tip manipulation mechanism Franklin, Jeremy Contini Alexander H. Slocum. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Mechanical Engineering. Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2009. Cataloged from PDF version of thesis. Includes bibliographical references (p. 59-61). The knowledge and technical expertise required for the development of telerobotic systems capable of needle distal tip manipulation is the focus of this thesis. An extensive prior literature review was conducted to examine (1) the current medical devices available to pulmonary radiologists and (2) the current steerable mechanism state of the art. Interviews were also conducted with interventional radiology and cardiology physicians at the Massachusetts General Hospital to define the mechanism functional requirements for a telerobotic system and a first order analysis was undertaken to evaluate three strategies. The selected strategy was based on the concept of deploying a flexible pre-curved stylet from a concentric straight cannula. Analytical models were developed to (1) understand what material properties are required to recover from the imposed strains, (2) compare stylet stiffness relative to each other and the cannulas, and (3) calculate the deployment and retraction forces required for moving the stylet relative to the cannula. Sixteen Nitinol stylets were prototyped and experiments were performed with four different diameter cannulas and an experimental setup and methodology was developed to measure the deployment and retraction forces. The data collected for 48 permutations of stylet diameter, stylet bend radius, and cannula gauge were compared to the analytical model. Retraction forces were measured between .277 and 13.9N, and deployment forces were measured between .191 and 6.95N. For a given cannula it was found that force increases as stylet diameter increases and bend radius decreases. The analytical model better matched the experimental retraction and deployment measurements for the smaller stylet diameters (0.508 and 0.635 mm) with low friction, retraction and deployment forces. It was found that the retraction and deployment force does not necessarily increase or decrease with cannula diameter and it was found that the stylets drawn through the 16 gauge cannula consistently had the lowest deployment and retraction forces recorded across the four cannulas tested. Ultimately, the experimental and analytical tools developed in this thesis helped us select appropriate needle materials and mechanism components for use in a telerobotic system that is under development. by Jeremy Contini Franklin. S.B. 2010-11-08T17:40:58Z 2010-11-08T17:40:58Z 2009 2009 Thesis http://hdl.handle.net/1721.1/59886 673712843 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 74 p. application/pdf Massachusetts Institute of Technology
collection NDLTD
language English
format Others
sources NDLTD
topic Mechanical Engineering.
spellingShingle Mechanical Engineering.
Franklin, Jeremy Contini
Characterization of a pre-curved needle for use in distal tip manipulation mechanism
description Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2009. === Cataloged from PDF version of thesis. === Includes bibliographical references (p. 59-61). === The knowledge and technical expertise required for the development of telerobotic systems capable of needle distal tip manipulation is the focus of this thesis. An extensive prior literature review was conducted to examine (1) the current medical devices available to pulmonary radiologists and (2) the current steerable mechanism state of the art. Interviews were also conducted with interventional radiology and cardiology physicians at the Massachusetts General Hospital to define the mechanism functional requirements for a telerobotic system and a first order analysis was undertaken to evaluate three strategies. The selected strategy was based on the concept of deploying a flexible pre-curved stylet from a concentric straight cannula. Analytical models were developed to (1) understand what material properties are required to recover from the imposed strains, (2) compare stylet stiffness relative to each other and the cannulas, and (3) calculate the deployment and retraction forces required for moving the stylet relative to the cannula. Sixteen Nitinol stylets were prototyped and experiments were performed with four different diameter cannulas and an experimental setup and methodology was developed to measure the deployment and retraction forces. The data collected for 48 permutations of stylet diameter, stylet bend radius, and cannula gauge were compared to the analytical model. Retraction forces were measured between .277 and 13.9N, and deployment forces were measured between .191 and 6.95N. For a given cannula it was found that force increases as stylet diameter increases and bend radius decreases. The analytical model better matched the experimental retraction and deployment measurements for the smaller stylet diameters (0.508 and 0.635 mm) with low friction, retraction and deployment forces. It was found that the retraction and deployment force does not necessarily increase or decrease with cannula diameter and it was found that the stylets drawn through the 16 gauge cannula consistently had the lowest deployment and retraction forces recorded across the four cannulas tested. Ultimately, the experimental and analytical tools developed in this thesis helped us select appropriate needle materials and mechanism components for use in a telerobotic system that is under development. === by Jeremy Contini Franklin. === S.B.
author2 Alexander H. Slocum.
author_facet Alexander H. Slocum.
Franklin, Jeremy Contini
author Franklin, Jeremy Contini
author_sort Franklin, Jeremy Contini
title Characterization of a pre-curved needle for use in distal tip manipulation mechanism
title_short Characterization of a pre-curved needle for use in distal tip manipulation mechanism
title_full Characterization of a pre-curved needle for use in distal tip manipulation mechanism
title_fullStr Characterization of a pre-curved needle for use in distal tip manipulation mechanism
title_full_unstemmed Characterization of a pre-curved needle for use in distal tip manipulation mechanism
title_sort characterization of a pre-curved needle for use in distal tip manipulation mechanism
publisher Massachusetts Institute of Technology
publishDate 2010
url http://hdl.handle.net/1721.1/59886
work_keys_str_mv AT franklinjeremycontini characterizationofaprecurvedneedleforuseindistaltipmanipulationmechanism
_version_ 1719038966051635200