A metabolically efficient leg brace
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006. === Includes bibliographical references (leaves 106-108). === Locomotion assistive devices can be broadly classified as either being passive or powered. Both have been created to aid in the leg's genera...
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Language: | English |
Published: |
Massachusetts Institute of Technology
2008
|
Subjects: | |
Online Access: | http://hdl.handle.net/1721.1/42300 |
id |
ndltd-MIT-oai-dspace.mit.edu-1721.1-42300 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-MIT-oai-dspace.mit.edu-1721.1-423002019-05-02T16:25:51Z A metabolically efficient leg brace Carvey, Andrew W. (Andrew Williams), 1980- David R. Wallace. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Mechanical Engineering. Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006. Includes bibliographical references (leaves 106-108). Locomotion assistive devices can be broadly classified as either being passive or powered. Both have been created to aid in the leg's generation of a ground reaction force which supports the torso during locomotion, yet their inherent design has limited their functional growth to date. While many differing gait simulations have demonstrated stable solutions for lossless gait cycles, passive orthoses only diminish the user's impediment, and though powered gait exoskeletons can augment strength and endurance, they are limited by their energy demanding actuators. In response to these two extremes, an energy efficient locomotion assist device was developed from the basis of lossless gait models that did not require external power, and augmented locomotion by harvesting the inherent energy associated with the gait cycle. The simplest anthropomorphic leg can be modeled with a peg-leg shank, a knee, a thigh and a point mass for the head, arms and torso. Using a tuned non-linear hardening torsion spring at the knee joint, the torso support that is required between the ground and pelvis for lossless gait simulations can be generated; allowing the close physical realization of the theoretical. It was found that a single torsion spring can generate the leg thrusts necessary for a realistic range of walking and running gait velocities without the addition of any external power. While frictional losses do inhibit the locomotion assist device's efficiency, since the device functions in parallel with the user's leg, any losses can be supplemented with minimal muscular activity. These results give strong indication that a new avenue of gait assistive and gait augmenting devices that require minimal actuation energy is feasible. by Andrew Williams Carvey. S.M. 2008-09-03T15:16:28Z 2008-09-03T15:16:28Z 2006 2006 Thesis http://hdl.handle.net/1721.1/42300 232359375 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 108 leaves application/pdf Massachusetts Institute of Technology |
collection |
NDLTD |
language |
English |
format |
Others
|
sources |
NDLTD |
topic |
Mechanical Engineering. |
spellingShingle |
Mechanical Engineering. Carvey, Andrew W. (Andrew Williams), 1980- A metabolically efficient leg brace |
description |
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006. === Includes bibliographical references (leaves 106-108). === Locomotion assistive devices can be broadly classified as either being passive or powered. Both have been created to aid in the leg's generation of a ground reaction force which supports the torso during locomotion, yet their inherent design has limited their functional growth to date. While many differing gait simulations have demonstrated stable solutions for lossless gait cycles, passive orthoses only diminish the user's impediment, and though powered gait exoskeletons can augment strength and endurance, they are limited by their energy demanding actuators. In response to these two extremes, an energy efficient locomotion assist device was developed from the basis of lossless gait models that did not require external power, and augmented locomotion by harvesting the inherent energy associated with the gait cycle. The simplest anthropomorphic leg can be modeled with a peg-leg shank, a knee, a thigh and a point mass for the head, arms and torso. Using a tuned non-linear hardening torsion spring at the knee joint, the torso support that is required between the ground and pelvis for lossless gait simulations can be generated; allowing the close physical realization of the theoretical. It was found that a single torsion spring can generate the leg thrusts necessary for a realistic range of walking and running gait velocities without the addition of any external power. While frictional losses do inhibit the locomotion assist device's efficiency, since the device functions in parallel with the user's leg, any losses can be supplemented with minimal muscular activity. These results give strong indication that a new avenue of gait assistive and gait augmenting devices that require minimal actuation energy is feasible. === by Andrew Williams Carvey. === S.M. |
author2 |
David R. Wallace. |
author_facet |
David R. Wallace. Carvey, Andrew W. (Andrew Williams), 1980- |
author |
Carvey, Andrew W. (Andrew Williams), 1980- |
author_sort |
Carvey, Andrew W. (Andrew Williams), 1980- |
title |
A metabolically efficient leg brace |
title_short |
A metabolically efficient leg brace |
title_full |
A metabolically efficient leg brace |
title_fullStr |
A metabolically efficient leg brace |
title_full_unstemmed |
A metabolically efficient leg brace |
title_sort |
metabolically efficient leg brace |
publisher |
Massachusetts Institute of Technology |
publishDate |
2008 |
url |
http://hdl.handle.net/1721.1/42300 |
work_keys_str_mv |
AT carveyandrewwandrewwilliams1980 ametabolicallyefficientlegbrace AT carveyandrewwandrewwilliams1980 metabolicallyefficientlegbrace |
_version_ |
1719040383592169472 |