Development and application of a 4-dimensional Computed Tomography simulator
Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2007. === This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections. === Includes bibliographical ref...
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Language: | English |
Published: |
Massachusetts Institute of Technology
2008
|
Subjects: | |
Online Access: | http://hdl.handle.net/1721.1/41542 |
id |
ndltd-MIT-oai-dspace.mit.edu-1721.1-41542 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-MIT-oai-dspace.mit.edu-1721.1-415422019-05-02T16:30:13Z Development and application of a 4-dimensional Computed Tomography simulator 4D CT simulator Chu, Alan George T.Y. Chen, William M. Wells, Gregory C. Sharp and John A. Wolfgang. Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science. Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science. Electrical Engineering and Computer Science. Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2007. This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections. Includes bibliographical references (p. 93-95). This thesis presents the development and application of a 4-Dimensional Computed Tomography (4D CT) simulation program. The simulation is used to understand and quantify the sources of image artifacts that arise from irregular patient breathing during 4D CT. Performance of the simulation is validated by comparing the simulation results with those of phantom experiments with CT scanners. The program simulates 4D CT scanning of objects of arbitrary size and shape and is extended to investigate the accuracy of gated radiotherapy. Experiments are performed using realistic breathing patterns from patients, in addition to synthetic ones for various studies. The simulation is used to study the effects of scan start time shift, breathing trace baseline drift, and hysteresis of internal organ and abdominal surface motion on the quality of 4D CT images. While 4D CT significantly reduces artifacts from helical scans of the thoracic and abdominal areas, a variety of different sources can still contribute to motioninduced artifacts in 4D CT. Since 4D CT is used to determine target margins for radiotherapy, proper precaution should be taken so that image artifacts do not lead to inaccurate treatment planning. Finally, this thesis discusses improvements in 4D CT and suggests additional methods to improve treatment planning for radiotherapy. by Alan Chu. M.Eng. 2008-05-19T14:58:39Z 2008-05-19T14:58:39Z 2007 2007 Thesis http://hdl.handle.net/1721.1/41542 219719532 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 95 p. application/pdf Massachusetts Institute of Technology |
collection |
NDLTD |
language |
English |
format |
Others
|
sources |
NDLTD |
topic |
Electrical Engineering and Computer Science. |
spellingShingle |
Electrical Engineering and Computer Science. Chu, Alan Development and application of a 4-dimensional Computed Tomography simulator |
description |
Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2007. === This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections. === Includes bibliographical references (p. 93-95). === This thesis presents the development and application of a 4-Dimensional Computed Tomography (4D CT) simulation program. The simulation is used to understand and quantify the sources of image artifacts that arise from irregular patient breathing during 4D CT. Performance of the simulation is validated by comparing the simulation results with those of phantom experiments with CT scanners. The program simulates 4D CT scanning of objects of arbitrary size and shape and is extended to investigate the accuracy of gated radiotherapy. Experiments are performed using realistic breathing patterns from patients, in addition to synthetic ones for various studies. The simulation is used to study the effects of scan start time shift, breathing trace baseline drift, and hysteresis of internal organ and abdominal surface motion on the quality of 4D CT images. While 4D CT significantly reduces artifacts from helical scans of the thoracic and abdominal areas, a variety of different sources can still contribute to motioninduced artifacts in 4D CT. Since 4D CT is used to determine target margins for radiotherapy, proper precaution should be taken so that image artifacts do not lead to inaccurate treatment planning. Finally, this thesis discusses improvements in 4D CT and suggests additional methods to improve treatment planning for radiotherapy. === by Alan Chu. === M.Eng. |
author2 |
George T.Y. Chen, William M. Wells, Gregory C. Sharp and John A. Wolfgang. |
author_facet |
George T.Y. Chen, William M. Wells, Gregory C. Sharp and John A. Wolfgang. Chu, Alan |
author |
Chu, Alan |
author_sort |
Chu, Alan |
title |
Development and application of a 4-dimensional Computed Tomography simulator |
title_short |
Development and application of a 4-dimensional Computed Tomography simulator |
title_full |
Development and application of a 4-dimensional Computed Tomography simulator |
title_fullStr |
Development and application of a 4-dimensional Computed Tomography simulator |
title_full_unstemmed |
Development and application of a 4-dimensional Computed Tomography simulator |
title_sort |
development and application of a 4-dimensional computed tomography simulator |
publisher |
Massachusetts Institute of Technology |
publishDate |
2008 |
url |
http://hdl.handle.net/1721.1/41542 |
work_keys_str_mv |
AT chualan developmentandapplicationofa4dimensionalcomputedtomographysimulator AT chualan 4dctsimulator |
_version_ |
1719041883386150912 |