A performance-based approach to retrofitting unreinforced masonry structures for seismic loads
Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2007. === Includes bibliographical references (leaves 58-59). === The structural inadequacy of existing unreinforced masonry (URM) buildings to resist possible seismic loading is a serious problem...
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Language: | English |
Published: |
Massachusetts Institute of Technology
2007
|
Subjects: | |
Online Access: | http://hdl.handle.net/1721.1/38944 |
id |
ndltd-MIT-oai-dspace.mit.edu-1721.1-38944 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-MIT-oai-dspace.mit.edu-1721.1-389442019-05-02T16:30:05Z A performance-based approach to retrofitting unreinforced masonry structures for seismic loads Performance-based approach to retrofitting URM structures for seismic loads Bouchard, Keith M. (Keith Michael) Jerome J. Connor. Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering. Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering. Civil and Environmental Engineering. Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2007. Includes bibliographical references (leaves 58-59). The structural inadequacy of existing unreinforced masonry (URM) buildings to resist possible seismic loading is a serious problem in many parts of the United States, including the Northeast and Midwest. The fact that many of these buildings are deemed historic structures or house critical facilities, like firehouses, emphasizes the need for an effective retrofitting program. The Federal Emergency Management Agency published a performance-based design code - FEMA 356 - in 2000 to use for analyzing and retrofitting existing structures. This code includes procedures for URM buildings. This paper applies these performance-based analysis procedures to a URM shear wall and compares the results to a modified analysis proposed by researchers. The wall is then rehabilitated using two common retrofit methods and again analyzed using the code. Recommendations are made for practicing engineers when evaluating URM structures for seismic loads. by Keith M. Bouchard. M.Eng. 2007-09-28T13:16:11Z 2007-09-28T13:16:11Z 2007 2007 Thesis http://hdl.handle.net/1721.1/38944 166269076 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 59, [47] leaves application/pdf Massachusetts Institute of Technology |
collection |
NDLTD |
language |
English |
format |
Others
|
sources |
NDLTD |
topic |
Civil and Environmental Engineering. |
spellingShingle |
Civil and Environmental Engineering. Bouchard, Keith M. (Keith Michael) A performance-based approach to retrofitting unreinforced masonry structures for seismic loads |
description |
Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2007. === Includes bibliographical references (leaves 58-59). === The structural inadequacy of existing unreinforced masonry (URM) buildings to resist possible seismic loading is a serious problem in many parts of the United States, including the Northeast and Midwest. The fact that many of these buildings are deemed historic structures or house critical facilities, like firehouses, emphasizes the need for an effective retrofitting program. The Federal Emergency Management Agency published a performance-based design code - FEMA 356 - in 2000 to use for analyzing and retrofitting existing structures. This code includes procedures for URM buildings. This paper applies these performance-based analysis procedures to a URM shear wall and compares the results to a modified analysis proposed by researchers. The wall is then rehabilitated using two common retrofit methods and again analyzed using the code. Recommendations are made for practicing engineers when evaluating URM structures for seismic loads. === by Keith M. Bouchard. === M.Eng. |
author2 |
Jerome J. Connor. |
author_facet |
Jerome J. Connor. Bouchard, Keith M. (Keith Michael) |
author |
Bouchard, Keith M. (Keith Michael) |
author_sort |
Bouchard, Keith M. (Keith Michael) |
title |
A performance-based approach to retrofitting unreinforced masonry structures for seismic loads |
title_short |
A performance-based approach to retrofitting unreinforced masonry structures for seismic loads |
title_full |
A performance-based approach to retrofitting unreinforced masonry structures for seismic loads |
title_fullStr |
A performance-based approach to retrofitting unreinforced masonry structures for seismic loads |
title_full_unstemmed |
A performance-based approach to retrofitting unreinforced masonry structures for seismic loads |
title_sort |
performance-based approach to retrofitting unreinforced masonry structures for seismic loads |
publisher |
Massachusetts Institute of Technology |
publishDate |
2007 |
url |
http://hdl.handle.net/1721.1/38944 |
work_keys_str_mv |
AT bouchardkeithmkeithmichael aperformancebasedapproachtoretrofittingunreinforcedmasonrystructuresforseismicloads AT bouchardkeithmkeithmichael performancebasedapproachtoretrofittingurmstructuresforseismicloads AT bouchardkeithmkeithmichael performancebasedapproachtoretrofittingunreinforcedmasonrystructuresforseismicloads |
_version_ |
1719041863045873664 |