Efficacy of Hammerstein models in capturing the dynamics of isometric muscle stimulated at various frequencies
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006. === Includes bibliographical references (p. 125-130). === Functional electrical stimulation (FES) can be employed more effectively as a rehabilitation intervention if neuroprosthetic controllers contain musc...
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Language: | English |
Published: |
Massachusetts Institute of Technology
2007
|
Subjects: | |
Online Access: | http://hdl.handle.net/1721.1/38274 |
id |
ndltd-MIT-oai-dspace.mit.edu-1721.1-38274 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-MIT-oai-dspace.mit.edu-1721.1-382742019-05-02T16:29:05Z Efficacy of Hammerstein models in capturing the dynamics of isometric muscle stimulated at various frequencies Chou, Danielle, 1981- Hugh M. Herr and David L. Trumper. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Massachusetts Institute of Technology. Dept. of Mechanical Engineering. Mechanical Engineering. Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006. Includes bibliographical references (p. 125-130). Functional electrical stimulation (FES) can be employed more effectively as a rehabilitation intervention if neuroprosthetic controllers contain muscle models appropriate to the behavioral regimes of interest. The goal of this thesis is to investigate the performance of one such model, the Hammerstein cascade, in describing isometric muscle force. We examine the effectiveness of Hammerstein models in predicting the isometric recruitment curve and dynamics of a muscle stimulated at fourteen frequencies between 1 to 100Hz. Explanted frog plantaris longus muscle is tested at the nominal isometric length only; hence, the muscle's force-length and force-velocity dependences are neither assumed nor ascertained. The pilot data are fitted using ten different models consisting of various combinations of linear dynamics with polynomial nonlinearities. Models identified using data with input stimulation frequencies of 20Hz and lower generate an average RMS error of 12% and are reliably stable (87 of 90 simulations). Between 25 to 40Hz, the average error generated by the estimated models is 10%, but the estimated dynamics are less stable (16 of 30 simulations). Above 40Hz, linear and Hammerstein nonlinear models fail to consistently generate stable dynamic estimates (11 of 30 simulations), and errors are large (eRMs = 44%). (cont.) Simulations also suggest Hammerstein models found iteratively do not perform much better than linear dynamic systems (in general, eRMS = 10 to 15%). In addition, simulations using iterated nonlinearities generate RMS errors that are comparable to those simulations using a fixed nonlinearity (both about 16%). These preliminary results warrant further investigation into the limits of Hammerstein models found iteratively in the identification of isometric muscle dynamics. by Danielle S. Chou. S.M. 2007-08-03T18:24:36Z 2007-08-03T18:24:36Z 2006 2006 Thesis http://hdl.handle.net/1721.1/38274 151243428 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 130 p. application/pdf Massachusetts Institute of Technology |
collection |
NDLTD |
language |
English |
format |
Others
|
sources |
NDLTD |
topic |
Mechanical Engineering. |
spellingShingle |
Mechanical Engineering. Chou, Danielle, 1981- Efficacy of Hammerstein models in capturing the dynamics of isometric muscle stimulated at various frequencies |
description |
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006. === Includes bibliographical references (p. 125-130). === Functional electrical stimulation (FES) can be employed more effectively as a rehabilitation intervention if neuroprosthetic controllers contain muscle models appropriate to the behavioral regimes of interest. The goal of this thesis is to investigate the performance of one such model, the Hammerstein cascade, in describing isometric muscle force. We examine the effectiveness of Hammerstein models in predicting the isometric recruitment curve and dynamics of a muscle stimulated at fourteen frequencies between 1 to 100Hz. Explanted frog plantaris longus muscle is tested at the nominal isometric length only; hence, the muscle's force-length and force-velocity dependences are neither assumed nor ascertained. The pilot data are fitted using ten different models consisting of various combinations of linear dynamics with polynomial nonlinearities. Models identified using data with input stimulation frequencies of 20Hz and lower generate an average RMS error of 12% and are reliably stable (87 of 90 simulations). Between 25 to 40Hz, the average error generated by the estimated models is 10%, but the estimated dynamics are less stable (16 of 30 simulations). Above 40Hz, linear and Hammerstein nonlinear models fail to consistently generate stable dynamic estimates (11 of 30 simulations), and errors are large (eRMs = 44%). === (cont.) Simulations also suggest Hammerstein models found iteratively do not perform much better than linear dynamic systems (in general, eRMS = 10 to 15%). In addition, simulations using iterated nonlinearities generate RMS errors that are comparable to those simulations using a fixed nonlinearity (both about 16%). These preliminary results warrant further investigation into the limits of Hammerstein models found iteratively in the identification of isometric muscle dynamics. === by Danielle S. Chou. === S.M. |
author2 |
Hugh M. Herr and David L. Trumper. |
author_facet |
Hugh M. Herr and David L. Trumper. Chou, Danielle, 1981- |
author |
Chou, Danielle, 1981- |
author_sort |
Chou, Danielle, 1981- |
title |
Efficacy of Hammerstein models in capturing the dynamics of isometric muscle stimulated at various frequencies |
title_short |
Efficacy of Hammerstein models in capturing the dynamics of isometric muscle stimulated at various frequencies |
title_full |
Efficacy of Hammerstein models in capturing the dynamics of isometric muscle stimulated at various frequencies |
title_fullStr |
Efficacy of Hammerstein models in capturing the dynamics of isometric muscle stimulated at various frequencies |
title_full_unstemmed |
Efficacy of Hammerstein models in capturing the dynamics of isometric muscle stimulated at various frequencies |
title_sort |
efficacy of hammerstein models in capturing the dynamics of isometric muscle stimulated at various frequencies |
publisher |
Massachusetts Institute of Technology |
publishDate |
2007 |
url |
http://hdl.handle.net/1721.1/38274 |
work_keys_str_mv |
AT choudanielle1981 efficacyofhammersteinmodelsincapturingthedynamicsofisometricmusclestimulatedatvariousfrequencies |
_version_ |
1719041361591664640 |