Novel monitoring system to diagnose rail track foundation problems
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2004. === This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections. === Includes bibliographical references (p....
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Language: | English |
Published: |
Massachusetts Institute of Technology
2007
|
Subjects: | |
Online Access: | http://dspace.mit.edu/handle/1721.1/30044 http://hdl.handle.net/1721.1/30044 |
id |
ndltd-MIT-oai-dspace.mit.edu-1721.1-30044 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-MIT-oai-dspace.mit.edu-1721.1-300442019-05-02T16:00:48Z Novel monitoring system to diagnose rail track foundation problems Aw, Eng Sew, 1978- John T. Germaine. Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering. Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering. Civil and Environmental Engineering. Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2004. This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections. Includes bibliographical references (p. 175-177). A low cost, remote monitoring system has been developed to diagnose rail track subgrade failures. The portable monitoring system consists of five liquid vertical settlement probes, one piezometer, a small data acquisition system and laptop, and an Internet communication with remote control capabilities. The probes are designed to be small, easily installed (within railbeds using a one-man auger), easily manufactured, and low cost. The sensors and data acquisition have been rigorously tested and calibrated in the laboratory. The settlement probes and piezometer are sensitive to changes in the atmospheric pressure and temperature, and calibration curves have been obtained to correct for these effects. The settlement probes are further subjected to silicone oil density changes due to differential temperature between the atmosphere and the ground, and these effects are minimised by a proposed correction method. The prototype monitoring system was installed through a two phase installation exercise at the bridge approach site in FAST (Facility for Accelerated Service Testing) at Transportation Technology Centre Inc (TTCI), Pueblo, Colorado, USA. Since there are virtually no settlements at the stiff, sandy bridge approach site, the sensors are evaluated for ideal stability and robustness while being subjected to well-defined Heavy Axle Train (HAL) loadings. A detailed evaluation of the prototype system found that probes installed at depths 1.0 to 1.5m within the subgrade did not achieve satisfactory measurement stability (i.e. measurements have a spurious drift), due principally to manufacturing defects. The prototype probes were sufficiently robust to survive installation within the subgrade but not within the ballast itself. (cont.) The probe designs have subsequently been refined to eliminate sources of drift, and have undergone more extensive calibration to account for differential temperature effects. These second generation probes are scheduled for field deployment as part of the on-going research. by Aw, Eng Sew. S.M. 2007-07-17T18:56:11Z 2007-07-17T18:56:11Z 2004 2004 Thesis http://dspace.mit.edu/handle/1721.1/30044 http://hdl.handle.net/1721.1/30044 55589792 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/30044 http://dspace.mit.edu/handle/1721.1/7582 177 p. application/pdf Massachusetts Institute of Technology |
collection |
NDLTD |
language |
English |
format |
Others
|
sources |
NDLTD |
topic |
Civil and Environmental Engineering. |
spellingShingle |
Civil and Environmental Engineering. Aw, Eng Sew, 1978- Novel monitoring system to diagnose rail track foundation problems |
description |
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2004. === This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections. === Includes bibliographical references (p. 175-177). === A low cost, remote monitoring system has been developed to diagnose rail track subgrade failures. The portable monitoring system consists of five liquid vertical settlement probes, one piezometer, a small data acquisition system and laptop, and an Internet communication with remote control capabilities. The probes are designed to be small, easily installed (within railbeds using a one-man auger), easily manufactured, and low cost. The sensors and data acquisition have been rigorously tested and calibrated in the laboratory. The settlement probes and piezometer are sensitive to changes in the atmospheric pressure and temperature, and calibration curves have been obtained to correct for these effects. The settlement probes are further subjected to silicone oil density changes due to differential temperature between the atmosphere and the ground, and these effects are minimised by a proposed correction method. The prototype monitoring system was installed through a two phase installation exercise at the bridge approach site in FAST (Facility for Accelerated Service Testing) at Transportation Technology Centre Inc (TTCI), Pueblo, Colorado, USA. Since there are virtually no settlements at the stiff, sandy bridge approach site, the sensors are evaluated for ideal stability and robustness while being subjected to well-defined Heavy Axle Train (HAL) loadings. A detailed evaluation of the prototype system found that probes installed at depths 1.0 to 1.5m within the subgrade did not achieve satisfactory measurement stability (i.e. measurements have a spurious drift), due principally to manufacturing defects. The prototype probes were sufficiently robust to survive installation within the subgrade but not within the ballast itself. === (cont.) The probe designs have subsequently been refined to eliminate sources of drift, and have undergone more extensive calibration to account for differential temperature effects. These second generation probes are scheduled for field deployment as part of the on-going research. === by Aw, Eng Sew. === S.M. |
author2 |
John T. Germaine. |
author_facet |
John T. Germaine. Aw, Eng Sew, 1978- |
author |
Aw, Eng Sew, 1978- |
author_sort |
Aw, Eng Sew, 1978- |
title |
Novel monitoring system to diagnose rail track foundation problems |
title_short |
Novel monitoring system to diagnose rail track foundation problems |
title_full |
Novel monitoring system to diagnose rail track foundation problems |
title_fullStr |
Novel monitoring system to diagnose rail track foundation problems |
title_full_unstemmed |
Novel monitoring system to diagnose rail track foundation problems |
title_sort |
novel monitoring system to diagnose rail track foundation problems |
publisher |
Massachusetts Institute of Technology |
publishDate |
2007 |
url |
http://dspace.mit.edu/handle/1721.1/30044 http://hdl.handle.net/1721.1/30044 |
work_keys_str_mv |
AT awengsew1978 novelmonitoringsystemtodiagnoserailtrackfoundationproblems |
_version_ |
1719032816237281280 |