In-situ depth monitoring for a deep reactive ion etcher using a white light interferometer with active vibration cancellation

Thesis: Ph. D., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2019 === Cataloged from PDF version of thesis. === Includes bibliographical references (pages 119-121). === Standard process development for micro and nanofabrication etching technologie...

Full description

Bibliographic Details
Main Author: Teale, Carson(Carson Arthur)
Other Authors: Martin Schmidt and George Barbastathis.
Format: Others
Language:English
Published: Massachusetts Institute of Technology 2019
Subjects:
Online Access:https://hdl.handle.net/1721.1/121726
id ndltd-MIT-oai-dspace.mit.edu-1721.1-121726
record_format oai_dc
spelling ndltd-MIT-oai-dspace.mit.edu-1721.1-1217262019-07-25T04:18:40Z In-situ depth monitoring for a deep reactive ion etcher using a white light interferometer with active vibration cancellation Teale, Carson(Carson Arthur) Martin Schmidt and George Barbastathis. Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science. Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science Electrical Engineering and Computer Science. Thesis: Ph. D., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2019 Cataloged from PDF version of thesis. Includes bibliographical references (pages 119-121). Standard process development for micro and nanofabrication etching technologies relies on open-loop trial and error testing of recipes to achieve optimal etch depths and uniformities. This strategy is inefficient for research and fabrication of novel devices where one-of-a-kind experiments cannot justify lengthy process development times. This thesis describes the development of an in-situ depth measurement device for real-time feedback of etch depth and uniformity. This device will help facilitate far shorter process development times, potentially enabling the desired etch to be achieved on the first process run. The depth imager consists of a wide-field, white light interferometer with a 12" working distance, capable of imaging across a 1/2" field of view. Active feedback from a co-propagating laser interferometer is used to stabilize the system against vibrations through a feedback loop that controls the position of the reference mirror using a piezo actuator. This scheme ties the accuracy of the white light depth scan to the stability of the laser wavelength, allowing for accurate step sizes without the need for an expensive scanning stage. The well defined sampling period allows for the phase sensitive detection of the white light interference signal, reducing amplitude fluctuations from plasma emissions. This design is able to image deep trenches with optically rough surfaces, etched directly into a silicon substrate with aspect ratios of 10 or more. The device is demonstrated on a custom built deep reactive ion etcher (DRIE), achieving a depth resolution of better than 1 [mu]m in the presence of large vibrations. by Carson Teale. Ph. D. Ph.D. Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science 2019-07-17T20:58:08Z 2019-07-17T20:58:08Z 2019 2019 Thesis https://hdl.handle.net/1721.1/121726 1102049006 eng MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission. http://dspace.mit.edu/handle/1721.1/7582 121 pages application/pdf Massachusetts Institute of Technology
collection NDLTD
language English
format Others
sources NDLTD
topic Electrical Engineering and Computer Science.
spellingShingle Electrical Engineering and Computer Science.
Teale, Carson(Carson Arthur)
In-situ depth monitoring for a deep reactive ion etcher using a white light interferometer with active vibration cancellation
description Thesis: Ph. D., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2019 === Cataloged from PDF version of thesis. === Includes bibliographical references (pages 119-121). === Standard process development for micro and nanofabrication etching technologies relies on open-loop trial and error testing of recipes to achieve optimal etch depths and uniformities. This strategy is inefficient for research and fabrication of novel devices where one-of-a-kind experiments cannot justify lengthy process development times. This thesis describes the development of an in-situ depth measurement device for real-time feedback of etch depth and uniformity. This device will help facilitate far shorter process development times, potentially enabling the desired etch to be achieved on the first process run. The depth imager consists of a wide-field, white light interferometer with a 12" working distance, capable of imaging across a 1/2" field of view. Active feedback from a co-propagating laser interferometer is used to stabilize the system against vibrations through a feedback loop that controls the position of the reference mirror using a piezo actuator. This scheme ties the accuracy of the white light depth scan to the stability of the laser wavelength, allowing for accurate step sizes without the need for an expensive scanning stage. The well defined sampling period allows for the phase sensitive detection of the white light interference signal, reducing amplitude fluctuations from plasma emissions. This design is able to image deep trenches with optically rough surfaces, etched directly into a silicon substrate with aspect ratios of 10 or more. The device is demonstrated on a custom built deep reactive ion etcher (DRIE), achieving a depth resolution of better than 1 [mu]m in the presence of large vibrations. === by Carson Teale. === Ph. D. === Ph.D. Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science
author2 Martin Schmidt and George Barbastathis.
author_facet Martin Schmidt and George Barbastathis.
Teale, Carson(Carson Arthur)
author Teale, Carson(Carson Arthur)
author_sort Teale, Carson(Carson Arthur)
title In-situ depth monitoring for a deep reactive ion etcher using a white light interferometer with active vibration cancellation
title_short In-situ depth monitoring for a deep reactive ion etcher using a white light interferometer with active vibration cancellation
title_full In-situ depth monitoring for a deep reactive ion etcher using a white light interferometer with active vibration cancellation
title_fullStr In-situ depth monitoring for a deep reactive ion etcher using a white light interferometer with active vibration cancellation
title_full_unstemmed In-situ depth monitoring for a deep reactive ion etcher using a white light interferometer with active vibration cancellation
title_sort in-situ depth monitoring for a deep reactive ion etcher using a white light interferometer with active vibration cancellation
publisher Massachusetts Institute of Technology
publishDate 2019
url https://hdl.handle.net/1721.1/121726
work_keys_str_mv AT tealecarsoncarsonarthur insitudepthmonitoringforadeepreactiveionetcherusingawhitelightinterferometerwithactivevibrationcancellation
_version_ 1719229523318276096