Arterial blood pressure estimation using ultrasound

Thesis: Ph. D., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2017. === Cataloged from PDF version of thesis. === Includes bibliographical references (pages 155-163). === While blood pressure is commonly used by doctors as an indicator of patient health, the available...

Full description

Bibliographic Details
Main Author: Zakrzewski, Aaron Michael
Other Authors: Brian W. Anthony.
Format: Others
Language:English
Published: Massachusetts Institute of Technology 2017
Subjects:
Online Access:http://hdl.handle.net/1721.1/111743
id ndltd-MIT-oai-dspace.mit.edu-1721.1-111743
record_format oai_dc
spelling ndltd-MIT-oai-dspace.mit.edu-1721.1-1117432019-05-02T16:24:37Z Arterial blood pressure estimation using ultrasound Zakrzewski, Aaron Michael Brian W. Anthony. Massachusetts Institute of Technology. Department of Mechanical Engineering. Massachusetts Institute of Technology. Department of Mechanical Engineering. Mechanical Engineering. Thesis: Ph. D., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2017. Cataloged from PDF version of thesis. Includes bibliographical references (pages 155-163). While blood pressure is commonly used by doctors as an indicator of patient health, the available techniques to measure the quantity suffer from many inconveniences such as cutting off blood flow, being cumbersome to use, being invasive, or being inaccurate. The research addresses many of these inconveniences by developing and evaluating a novel ultrasound-based blood pressure measurement technique that is non-invasive and non-occlusive. The technique proceeds in three steps: data acquisition, data reduction, and optimization. In the data acquisition step, an ultrasound probe is placed on a patient's artery and a force sweep is conducted such that the contact force gradually increases; both the applied force and B-Mode images are recorded. In the data-reduction step, the Star-Kalman filter is applied in order to find the size of the artery in each image frame captured. The segmentation data and contact force data are inputs into the optimization step which consists of two sequential optimizations; the first makes many modeling assumptions and gives an estimate of pulse pressure while the second makes less assumptions and uses the approximation of pulse pressure to obtain absolute values of systolic and diastolic blood pressure. Central to the optimization algorithm is a computational biomechanical model of the artery and surrounding tissue, which is numerically modeled using finite elements. The impact of major modeling assumptions is corrected with a one time calibration. The technique is validated on a number of different data sets. Major data sets discussed include data taken on the carotid artery of (1) 24 single-visit nominally healthy volunteers, (2) two multi-visit nominally healthy volunteers, (3) one multi-visit hypertensive volunteer, and (4) one multi-visit hypotensive volunteer; additional miscellaneous data sets are taken and analyzed as part of this dissertation. The algorithm performance is quantified against readings from an automatic oscillometric cuff. Results show that systolic and diastolic blood pressures can be predicted by the algorithm. The technology discussed in this dissertation represents a proof-of-concept of a blood pressure measurement technique that could occupy a clinical middle ground between the invasive catheter and cuff-based techniques. by Aaron Michael Zakrzewski. Ph. D. 2017-10-04T15:06:28Z 2017-10-04T15:06:28Z 2017 2017 Thesis http://hdl.handle.net/1721.1/111743 1004393248 eng MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission. http://dspace.mit.edu/handle/1721.1/7582 163 pages application/pdf Massachusetts Institute of Technology
collection NDLTD
language English
format Others
sources NDLTD
topic Mechanical Engineering.
spellingShingle Mechanical Engineering.
Zakrzewski, Aaron Michael
Arterial blood pressure estimation using ultrasound
description Thesis: Ph. D., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2017. === Cataloged from PDF version of thesis. === Includes bibliographical references (pages 155-163). === While blood pressure is commonly used by doctors as an indicator of patient health, the available techniques to measure the quantity suffer from many inconveniences such as cutting off blood flow, being cumbersome to use, being invasive, or being inaccurate. The research addresses many of these inconveniences by developing and evaluating a novel ultrasound-based blood pressure measurement technique that is non-invasive and non-occlusive. The technique proceeds in three steps: data acquisition, data reduction, and optimization. In the data acquisition step, an ultrasound probe is placed on a patient's artery and a force sweep is conducted such that the contact force gradually increases; both the applied force and B-Mode images are recorded. In the data-reduction step, the Star-Kalman filter is applied in order to find the size of the artery in each image frame captured. The segmentation data and contact force data are inputs into the optimization step which consists of two sequential optimizations; the first makes many modeling assumptions and gives an estimate of pulse pressure while the second makes less assumptions and uses the approximation of pulse pressure to obtain absolute values of systolic and diastolic blood pressure. Central to the optimization algorithm is a computational biomechanical model of the artery and surrounding tissue, which is numerically modeled using finite elements. The impact of major modeling assumptions is corrected with a one time calibration. The technique is validated on a number of different data sets. Major data sets discussed include data taken on the carotid artery of (1) 24 single-visit nominally healthy volunteers, (2) two multi-visit nominally healthy volunteers, (3) one multi-visit hypertensive volunteer, and (4) one multi-visit hypotensive volunteer; additional miscellaneous data sets are taken and analyzed as part of this dissertation. The algorithm performance is quantified against readings from an automatic oscillometric cuff. Results show that systolic and diastolic blood pressures can be predicted by the algorithm. The technology discussed in this dissertation represents a proof-of-concept of a blood pressure measurement technique that could occupy a clinical middle ground between the invasive catheter and cuff-based techniques. === by Aaron Michael Zakrzewski. === Ph. D.
author2 Brian W. Anthony.
author_facet Brian W. Anthony.
Zakrzewski, Aaron Michael
author Zakrzewski, Aaron Michael
author_sort Zakrzewski, Aaron Michael
title Arterial blood pressure estimation using ultrasound
title_short Arterial blood pressure estimation using ultrasound
title_full Arterial blood pressure estimation using ultrasound
title_fullStr Arterial blood pressure estimation using ultrasound
title_full_unstemmed Arterial blood pressure estimation using ultrasound
title_sort arterial blood pressure estimation using ultrasound
publisher Massachusetts Institute of Technology
publishDate 2017
url http://hdl.handle.net/1721.1/111743
work_keys_str_mv AT zakrzewskiaaronmichael arterialbloodpressureestimationusingultrasound
_version_ 1719039688176566272