Shear bond strengths of two new self-etching primers
Purpose: To evaluate the in vitro shear bond strength (SBS) of orthodontic attachments using 2 self-etching primers (SEP): iBOND and G-Bond. Methods: 180 molars were randomly divided into 12 groups. Teeth were bonded with a stainless steel button using Transbond XT composite. The bonding agents w...
Main Author: | |
---|---|
Other Authors: | |
Language: | en_US |
Published: |
2010
|
Subjects: | |
Online Access: | http://hdl.handle.net/1993/4008 |
id |
ndltd-MANITOBA-oai-mspace.lib.umanitoba.ca-1993-4008 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-MANITOBA-oai-mspace.lib.umanitoba.ca-1993-40082014-01-31T03:32:03Z Shear bond strengths of two new self-etching primers Ho, Andy CS Akyalcin, Sercan (Preventive Dental Science) Swain, Vanessa (Restorative Dentistry) Wiltshire, William (Preventive Dental Science) Orthodontics Purpose: To evaluate the in vitro shear bond strength (SBS) of orthodontic attachments using 2 self-etching primers (SEP): iBOND and G-Bond. Methods: 180 molars were randomly divided into 12 groups. Teeth were bonded with a stainless steel button using Transbond XT composite. The bonding agents were iBOND, G-Bond, Transbond Plus SEP and Transbond XT primer (control). SBS’s immediately, 24hours and 3months were measured with their Adhesive Remnant Index (ARI). Results: Transbond XT primer (11.22MPa) had a significantly higher immediate SBS than Transbond Plus SEP (5.32MPa), iBOND (6.69MPa) and G-Bond (8.30MPa). 24 hours, Transbond XT primer (16.65MPa) and Transbond Plus SEP (13.20MPa) had a significant increase in their SBS. No difference was observed at 3 months. ARI were significantly different between the groups at all time points. Conclusions: iBOND and G-Bond yielded sufficient SBS’s over the three time points that may be sufficient to withstand occlusal and light archwire forces. 2010-06-25T13:08:46Z 2010-06-25T13:08:46Z 2010-06-25T13:08:46Z http://hdl.handle.net/1993/4008 en_US |
collection |
NDLTD |
language |
en_US |
sources |
NDLTD |
topic |
Orthodontics |
spellingShingle |
Orthodontics Ho, Andy CS Shear bond strengths of two new self-etching primers |
description |
Purpose: To evaluate the in vitro shear bond strength (SBS) of orthodontic attachments using 2 self-etching primers (SEP): iBOND and G-Bond.
Methods: 180 molars were randomly divided into 12 groups. Teeth were bonded with a stainless steel button using Transbond XT composite. The bonding agents were iBOND, G-Bond, Transbond Plus SEP and Transbond XT primer (control). SBS’s immediately, 24hours and 3months were measured with their Adhesive Remnant Index (ARI).
Results: Transbond XT primer (11.22MPa) had a significantly higher immediate SBS than Transbond Plus SEP (5.32MPa), iBOND (6.69MPa) and G-Bond (8.30MPa). 24 hours, Transbond XT primer (16.65MPa) and Transbond Plus SEP (13.20MPa) had a significant increase in their SBS. No difference was observed at 3 months. ARI were significantly different between the groups at all time points.
Conclusions: iBOND and G-Bond yielded sufficient SBS’s over the three time points that may be sufficient to withstand occlusal and light archwire forces. |
author2 |
Akyalcin, Sercan (Preventive Dental Science) |
author_facet |
Akyalcin, Sercan (Preventive Dental Science) Ho, Andy CS |
author |
Ho, Andy CS |
author_sort |
Ho, Andy CS |
title |
Shear bond strengths of two new self-etching primers |
title_short |
Shear bond strengths of two new self-etching primers |
title_full |
Shear bond strengths of two new self-etching primers |
title_fullStr |
Shear bond strengths of two new self-etching primers |
title_full_unstemmed |
Shear bond strengths of two new self-etching primers |
title_sort |
shear bond strengths of two new self-etching primers |
publishDate |
2010 |
url |
http://hdl.handle.net/1993/4008 |
work_keys_str_mv |
AT hoandycs shearbondstrengthsoftwonewselfetchingprimers |
_version_ |
1716628844740345856 |