The Use of the BANG-3 Polymer Gel to Quantify the Three-Dimensional Dose Distribution of IMRT

The sophistication of radiation therapy delivery techniques at Mary Bird Perkins Cancer Center (MBPCC) creates the need for an advanced dosimetric system that can quantify and verify the dose distributions in three-dimensions. Current dosimetric systems perform this dose analysis in only one or two...

Full description

Bibliographic Details
Main Author: Bruce, Paul Anthony
Other Authors: Sheldon Johnson
Format: Others
Language:en
Published: LSU 2003
Subjects:
Online Access:http://etd.lsu.edu/docs/available/etd-0305103-143757/
id ndltd-LSU-oai-etd.lsu.edu-etd-0305103-143757
record_format oai_dc
spelling ndltd-LSU-oai-etd.lsu.edu-etd-0305103-1437572013-01-07T22:48:25Z The Use of the BANG-3 Polymer Gel to Quantify the Three-Dimensional Dose Distribution of IMRT Bruce, Paul Anthony Physics and Astronomy The sophistication of radiation therapy delivery techniques at Mary Bird Perkins Cancer Center (MBPCC) creates the need for an advanced dosimetric system that can quantify and verify the dose distributions in three-dimensions. Current dosimetric systems perform this dose analysis in only one or two dimensions. This paper evaluates the application of BANG-3 polymer gel dosimetry to quantify the 3-D dose distribution of Intensity-Modulated Radiation Therapy (IMRT) using a "step and shoot" approach. The gel was irradiated by 10 MV photons at a dose rate of 400 MU/min. Relaxation rate maps were computed from proton density and T<sub>2</sub>-weighted magnetic resonance images acquired with a GE Horizon 1.5T scanner; scans were performed 5 days and 2 months post-irradiation. The dose distribution within the gel was compared to the dose distribution calculated by the Pinnacle<sup>3</sup> planning system. Three techniques were used for analysis: image subtraction, dose-volume analysis and contour analysis. Also, a dose correction factor was used to attempt to correct for excess dose delivered to the gel as the gels were erroneously placed in the treatment room two days prior to irradiation. Corrected 5-day post-irradiation dose maps show reasonable agreement with the Pinnacle<sup>3</sup> plan. The absolute measurement error was +/-50 cGy; however, the relative errors were large compared to the total dose of 2 Gy delivered to the gel. Delivering a larger total dose should reduce the relative error to a reasonable magnitude. Exposure to light and other environmental factors caused substantial additional polymerization with time. The results of this project indicate that polymer gel dosimetry could be a useful routine 3D dosimetric technique at MBPCC. However, utilizing a commercial scanning service may simplify use of the gels. Sheldon Johnson Mark Williams Thomas Kirby Oscar Hidalgo Kenneth Matthews LSU 2003-03-11 text application/pdf http://etd.lsu.edu/docs/available/etd-0305103-143757/ http://etd.lsu.edu/docs/available/etd-0305103-143757/ en unrestricted I hereby grant to LSU or its agents the right to archive and to make available my thesis or dissertation in whole or in part in the University Libraries in all forms of media, now or hereafter known. I retain all proprietary rights, such as patent rights. I also retain the right to use in future works (such as articles or books) all or part of this thesis or dissertation.
collection NDLTD
language en
format Others
sources NDLTD
topic Physics and Astronomy
spellingShingle Physics and Astronomy
Bruce, Paul Anthony
The Use of the BANG-3 Polymer Gel to Quantify the Three-Dimensional Dose Distribution of IMRT
description The sophistication of radiation therapy delivery techniques at Mary Bird Perkins Cancer Center (MBPCC) creates the need for an advanced dosimetric system that can quantify and verify the dose distributions in three-dimensions. Current dosimetric systems perform this dose analysis in only one or two dimensions. This paper evaluates the application of BANG-3 polymer gel dosimetry to quantify the 3-D dose distribution of Intensity-Modulated Radiation Therapy (IMRT) using a "step and shoot" approach. The gel was irradiated by 10 MV photons at a dose rate of 400 MU/min. Relaxation rate maps were computed from proton density and T<sub>2</sub>-weighted magnetic resonance images acquired with a GE Horizon 1.5T scanner; scans were performed 5 days and 2 months post-irradiation. The dose distribution within the gel was compared to the dose distribution calculated by the Pinnacle<sup>3</sup> planning system. Three techniques were used for analysis: image subtraction, dose-volume analysis and contour analysis. Also, a dose correction factor was used to attempt to correct for excess dose delivered to the gel as the gels were erroneously placed in the treatment room two days prior to irradiation. Corrected 5-day post-irradiation dose maps show reasonable agreement with the Pinnacle<sup>3</sup> plan. The absolute measurement error was +/-50 cGy; however, the relative errors were large compared to the total dose of 2 Gy delivered to the gel. Delivering a larger total dose should reduce the relative error to a reasonable magnitude. Exposure to light and other environmental factors caused substantial additional polymerization with time. The results of this project indicate that polymer gel dosimetry could be a useful routine 3D dosimetric technique at MBPCC. However, utilizing a commercial scanning service may simplify use of the gels.
author2 Sheldon Johnson
author_facet Sheldon Johnson
Bruce, Paul Anthony
author Bruce, Paul Anthony
author_sort Bruce, Paul Anthony
title The Use of the BANG-3 Polymer Gel to Quantify the Three-Dimensional Dose Distribution of IMRT
title_short The Use of the BANG-3 Polymer Gel to Quantify the Three-Dimensional Dose Distribution of IMRT
title_full The Use of the BANG-3 Polymer Gel to Quantify the Three-Dimensional Dose Distribution of IMRT
title_fullStr The Use of the BANG-3 Polymer Gel to Quantify the Three-Dimensional Dose Distribution of IMRT
title_full_unstemmed The Use of the BANG-3 Polymer Gel to Quantify the Three-Dimensional Dose Distribution of IMRT
title_sort use of the bang-3 polymer gel to quantify the three-dimensional dose distribution of imrt
publisher LSU
publishDate 2003
url http://etd.lsu.edu/docs/available/etd-0305103-143757/
work_keys_str_mv AT brucepaulanthony theuseofthebang3polymergeltoquantifythethreedimensionaldosedistributionofimrt
AT brucepaulanthony useofthebang3polymergeltoquantifythethreedimensionaldosedistributionofimrt
_version_ 1716476354970517504