The Behaviour of Plank (Tongue and Groove) Wood Decking Under the Effects of Uniformly Distributed and Concentrated Loads

Plank (tongue and groove) wood decking is a product that is commonly used in post and beam timber construction to transfer gravity loads on roofs and floors. In 2010, The National Building Code of Canada changed the application area of the specified concentrated roof live loads from 750 mm x 750 mm...

Full description

Bibliographic Details
Main Author: Rocchi, Kevin
Language:en
Published: 2013
Subjects:
Online Access:http://hdl.handle.net/10393/26183
Description
Summary:Plank (tongue and groove) wood decking is a product that is commonly used in post and beam timber construction to transfer gravity loads on roofs and floors. In 2010, The National Building Code of Canada changed the application area of the specified concentrated roof live loads from 750 mm x 750 mm to 200 mm x 200 mm. The change was made to better reflect the area which a construction worker with equipment occupies. Preliminary analysis showed that the change in the application area of concentrated loads may have a significant impact on the design of decking systems. Little research or development has been done on plank decking since the 1950’s and 1960’s. An experimental program was undertaken at the University of Ottawa’s structural laboratory to better understand the behaviour of plank decking under uniformly distributed and concentrated loads. Non-destructive and destructive tests were conducted on plank decking systems to investigate their stiffness and failure mode characteristics under uniformly distributed as well as concentrated loads. The experimental test program was complimented with a detailed finite element model in order to predict the behaviour of a plank decking system, especially the force transfer between decks through the tongue and groove joint. The study showed that the published deflection coefficients for uniformly distributed loads can accurately predict the three types of decking layup patterns specified in the Canadian Design Standard (CSA O86, 2009). For unbalanced uniformly distributed loads on two-span continuous layup, it was found that the deflection coefficient of 0.42 was non-conservative. It was also found that under concentrated loads, the stiffness of the decking system increased significantly as more boards were added. A deflection coefficient of 0.40 is appropriate to calculate the deflection for the three types of decking layup patterns specified in the Canadian Design Standard (CSA O86, 2009) under concentrated load on an area of 200 mm by 200 mm. Significant load sharing was observed for plank decking under concentrated loads. An increase in capacity of about 1.5 to 2.5 times the capacity of the loaded boards was found. Furthermore, it was found that placing sheathing on top of a decking system had a significant effect in the case of concentrated load with an increase of over 50% in stiffness and over 100% in ultimate capacity.