A METHOD OF DETECTING TOTAL VIABLE ORGANISMS IN WATER BASED ON SOLID-PHASE MICROEXTRACTION AND FLUORESCENT SIGNAL DETECTION

Microorganisms are monitored as a key indicator of water quality. Measurement of “total viable organisms” (TVO, similar to “heterotrophic plate count”, HPC) is used to indicate the general hygiene level of the water, and is often used to assess water treatment. Automated, instrumental TVO detectio...

Full description

Bibliographic Details
Main Author: Zhang, MORU
Other Authors: Queen's University (Kingston, Ont.). Theses (Queen's University (Kingston, Ont.))
Language:en
en
Published: 2013
Subjects:
Online Access:http://hdl.handle.net/1974/8139
id ndltd-LACETR-oai-collectionscanada.gc.ca-OKQ.1974-8139
record_format oai_dc
spelling ndltd-LACETR-oai-collectionscanada.gc.ca-OKQ.1974-81392013-12-20T03:40:56ZA METHOD OF DETECTING TOTAL VIABLE ORGANISMS IN WATER BASED ON SOLID-PHASE MICROEXTRACTION AND FLUORESCENT SIGNAL DETECTIONZhang, MORUSolid phase microextractionWater qualityTotal viable organismsFluorescent signalBacteria detectionMicroorganisms are monitored as a key indicator of water quality. Measurement of “total viable organisms” (TVO, similar to “heterotrophic plate count”, HPC) is used to indicate the general hygiene level of the water, and is often used to assess water treatment. Automated, instrumental TVO detection in water samples using an enzyme reaction method shortens the detection time compared to conventional HPC methods. A method that can detect TVO without interference in water samples by monitoring enzyme activities through fluorescent signals in small custom sample cells was developed. In this method, fluorogenic substrates were cleaved by specific enzymes to make fluorescent products, which then partitioned into a non-polar siloxane polymer film on the bottom of the sample cell. A miniature spectrometer monitored fluorescence in the polymer to give a present/absent result for bacteria. There is no interference from sample color and turbidity because the light never passes through the sample matrix. Eight substrates that can be converted by six different enzymes were characterized. These had fluorescent products coupled to glucose, glucuronic acid, galactose, phosphate, sulfate and alanine. Four different products were produced, providing detection of some enzymes simultaneously but independently, depending on the substrates chosen. Candidate fluorescent products were first tested with different siloxane polymers and two dimethyl-siloxane polymers were identified to detect all the products separately. Fifteen laboratory bacteria strains (including E. coli, Klebsiella pneumonia, and Pseudomonas aeruginosa) were added individually to a substrate solution containing minimal nutrients and incubated. All bacteria types were successfully detected by at least one substrate, with most detected by several substrates. Sterility of water samples from lake water, treated lake water and tap water were tested with those eight substrates separately or in combination. The lake water had the highest bacteria level and included coliforms and possibly E. coli. Treated lake water and tap water were E. coli and coliforms free, and were safe for drinking. Treated lake water had higher TVO levels than tap water, indicating a lower hygiene level. The results of combined substrate tests matched the corresponding single substrate tests, suggesting specific bacteria strains can be distinguished in a single test.Thesis (Master, Chemistry) -- Queen's University, 2013-08-01 18:03:54.111Queen's University (Kingston, Ont.). Theses (Queen's University (Kingston, Ont.))2013-07-31 12:24:46.612013-08-01 18:03:54.1112013-08-02T22:26:44Z2013-08-02Thesishttp://hdl.handle.net/1974/8139enenCanadian thesesThis publication is made available by the authority of the copyright owner solely for the purpose of private study and research and may not be copied or reproduced except as permitted by the copyright laws without written authority from the copyright owner.
collection NDLTD
language en
en
sources NDLTD
topic Solid phase microextraction
Water quality
Total viable organisms
Fluorescent signal
Bacteria detection
spellingShingle Solid phase microextraction
Water quality
Total viable organisms
Fluorescent signal
Bacteria detection
Zhang, MORU
A METHOD OF DETECTING TOTAL VIABLE ORGANISMS IN WATER BASED ON SOLID-PHASE MICROEXTRACTION AND FLUORESCENT SIGNAL DETECTION
description Microorganisms are monitored as a key indicator of water quality. Measurement of “total viable organisms” (TVO, similar to “heterotrophic plate count”, HPC) is used to indicate the general hygiene level of the water, and is often used to assess water treatment. Automated, instrumental TVO detection in water samples using an enzyme reaction method shortens the detection time compared to conventional HPC methods. A method that can detect TVO without interference in water samples by monitoring enzyme activities through fluorescent signals in small custom sample cells was developed. In this method, fluorogenic substrates were cleaved by specific enzymes to make fluorescent products, which then partitioned into a non-polar siloxane polymer film on the bottom of the sample cell. A miniature spectrometer monitored fluorescence in the polymer to give a present/absent result for bacteria. There is no interference from sample color and turbidity because the light never passes through the sample matrix. Eight substrates that can be converted by six different enzymes were characterized. These had fluorescent products coupled to glucose, glucuronic acid, galactose, phosphate, sulfate and alanine. Four different products were produced, providing detection of some enzymes simultaneously but independently, depending on the substrates chosen. Candidate fluorescent products were first tested with different siloxane polymers and two dimethyl-siloxane polymers were identified to detect all the products separately. Fifteen laboratory bacteria strains (including E. coli, Klebsiella pneumonia, and Pseudomonas aeruginosa) were added individually to a substrate solution containing minimal nutrients and incubated. All bacteria types were successfully detected by at least one substrate, with most detected by several substrates. Sterility of water samples from lake water, treated lake water and tap water were tested with those eight substrates separately or in combination. The lake water had the highest bacteria level and included coliforms and possibly E. coli. Treated lake water and tap water were E. coli and coliforms free, and were safe for drinking. Treated lake water had higher TVO levels than tap water, indicating a lower hygiene level. The results of combined substrate tests matched the corresponding single substrate tests, suggesting specific bacteria strains can be distinguished in a single test. === Thesis (Master, Chemistry) -- Queen's University, 2013-08-01 18:03:54.111
author2 Queen's University (Kingston, Ont.). Theses (Queen's University (Kingston, Ont.))
author_facet Queen's University (Kingston, Ont.). Theses (Queen's University (Kingston, Ont.))
Zhang, MORU
author Zhang, MORU
author_sort Zhang, MORU
title A METHOD OF DETECTING TOTAL VIABLE ORGANISMS IN WATER BASED ON SOLID-PHASE MICROEXTRACTION AND FLUORESCENT SIGNAL DETECTION
title_short A METHOD OF DETECTING TOTAL VIABLE ORGANISMS IN WATER BASED ON SOLID-PHASE MICROEXTRACTION AND FLUORESCENT SIGNAL DETECTION
title_full A METHOD OF DETECTING TOTAL VIABLE ORGANISMS IN WATER BASED ON SOLID-PHASE MICROEXTRACTION AND FLUORESCENT SIGNAL DETECTION
title_fullStr A METHOD OF DETECTING TOTAL VIABLE ORGANISMS IN WATER BASED ON SOLID-PHASE MICROEXTRACTION AND FLUORESCENT SIGNAL DETECTION
title_full_unstemmed A METHOD OF DETECTING TOTAL VIABLE ORGANISMS IN WATER BASED ON SOLID-PHASE MICROEXTRACTION AND FLUORESCENT SIGNAL DETECTION
title_sort method of detecting total viable organisms in water based on solid-phase microextraction and fluorescent signal detection
publishDate 2013
url http://hdl.handle.net/1974/8139
work_keys_str_mv AT zhangmoru amethodofdetectingtotalviableorganismsinwaterbasedonsolidphasemicroextractionandfluorescentsignaldetection
AT zhangmoru methodofdetectingtotalviableorganismsinwaterbasedonsolidphasemicroextractionandfluorescentsignaldetection
_version_ 1716621693381771264