Polarimeter for an Accelerated Spheromak

A three-beam heterodyne polarimeter has been designed and constructed to measure line-integrated density and Faraday rotation of accelerated spheromak plasmas in the Plasma Injector 1 and 2 devices (PI-1, PI-2) at General Fusion Inc. Faraday rotation is a function of the local magnetic field and ele...

Full description

Bibliographic Details
Main Author: Carle, PATRICK
Other Authors: Queen's University (Kingston, Ont.). Theses (Queen's University (Kingston, Ont.))
Language:en
en
Published: 2014
Subjects:
Online Access:http://hdl.handle.net/1974/12163
id ndltd-LACETR-oai-collectionscanada.gc.ca-OKQ.1974-12163
record_format oai_dc
spelling ndltd-LACETR-oai-collectionscanada.gc.ca-OKQ.1974-121632014-05-07T03:53:32ZPolarimeter for an Accelerated SpheromakCarle, PATRICKenergyplasmamagnetized target fusionspheromakpolarimetermagnetic fieldfusionA three-beam heterodyne polarimeter has been designed and constructed to measure line-integrated density and Faraday rotation of accelerated spheromak plasmas in the Plasma Injector 1 and 2 devices (PI-1, PI-2) at General Fusion Inc. Faraday rotation is a function of the local magnetic field and electron density. Therefore, the polarimeter has the potential to provide information on the internal magnetic field of the plasma. A typical spheromak is about 1m in length and is accelerated to speeds on the order of 100km/s. At a bandwidth of 1MHz, the polarimeter can axially resolve the spheromak down to about 10cm. The polarimeter uses a $\nit{CO}_2$ laser that produces a Faraday rotation signal of about $0.5\degrees$ for a typical plasma with density and magnetic field on the order of $\ee{21}\mmt$ and 1T. The Faraday rotation measurement noise floor for a null signal is about $0.1\degrees$. Two important sources of Faraday rotation error are the ellipticity and collinearity of the plasma-immersed beams. These error sources are examined by sending the plasma beams through a rotating optic to mimic the path through a dense, magnetized plasma. The error due to the ellipticity effect has been reduced to below the noise floor by careful alignment and use of zero phase reflectors that minimize elliptical polarization of the beams. Collinearity error has been greatly improved by aligning the beams with a rotating ZnSe wedge. Measurements after the alignment match well with a model Faraday rotation signal generated from magnetic probe measurements. However, beam collinearity continues to be a significant source of error. For regions with strong density gradients, the size of this error can be on the order of the signal magnitude. For future work, steps should be taken to improve the alignment of the two plasma-immersed beams, and to shorten the length of the beam path to further reduce the beam collinearity error.Thesis (Ph.D, Physics, Engineering Physics and Astronomy) -- Queen's University, 2014-04-30 22:17:18.648Queen's University (Kingston, Ont.). Theses (Queen's University (Kingston, Ont.))2014-04-30 22:17:18.6482014-05-01T17:17:20Z2014-05-01T17:17:20Z2014-05-01Thesishttp://hdl.handle.net/1974/12163enenCanadian thesesThis publication is made available by the authority of the copyright owner solely for the purpose of private study and research and may not be copied or reproduced except as permitted by the copyright laws without written authority from the copyright owner.
collection NDLTD
language en
en
sources NDLTD
topic energy
plasma
magnetized target fusion
spheromak
polarimeter
magnetic field
fusion
spellingShingle energy
plasma
magnetized target fusion
spheromak
polarimeter
magnetic field
fusion
Carle, PATRICK
Polarimeter for an Accelerated Spheromak
description A three-beam heterodyne polarimeter has been designed and constructed to measure line-integrated density and Faraday rotation of accelerated spheromak plasmas in the Plasma Injector 1 and 2 devices (PI-1, PI-2) at General Fusion Inc. Faraday rotation is a function of the local magnetic field and electron density. Therefore, the polarimeter has the potential to provide information on the internal magnetic field of the plasma. A typical spheromak is about 1m in length and is accelerated to speeds on the order of 100km/s. At a bandwidth of 1MHz, the polarimeter can axially resolve the spheromak down to about 10cm. The polarimeter uses a $\nit{CO}_2$ laser that produces a Faraday rotation signal of about $0.5\degrees$ for a typical plasma with density and magnetic field on the order of $\ee{21}\mmt$ and 1T. The Faraday rotation measurement noise floor for a null signal is about $0.1\degrees$. Two important sources of Faraday rotation error are the ellipticity and collinearity of the plasma-immersed beams. These error sources are examined by sending the plasma beams through a rotating optic to mimic the path through a dense, magnetized plasma. The error due to the ellipticity effect has been reduced to below the noise floor by careful alignment and use of zero phase reflectors that minimize elliptical polarization of the beams. Collinearity error has been greatly improved by aligning the beams with a rotating ZnSe wedge. Measurements after the alignment match well with a model Faraday rotation signal generated from magnetic probe measurements. However, beam collinearity continues to be a significant source of error. For regions with strong density gradients, the size of this error can be on the order of the signal magnitude. For future work, steps should be taken to improve the alignment of the two plasma-immersed beams, and to shorten the length of the beam path to further reduce the beam collinearity error. === Thesis (Ph.D, Physics, Engineering Physics and Astronomy) -- Queen's University, 2014-04-30 22:17:18.648
author2 Queen's University (Kingston, Ont.). Theses (Queen's University (Kingston, Ont.))
author_facet Queen's University (Kingston, Ont.). Theses (Queen's University (Kingston, Ont.))
Carle, PATRICK
author Carle, PATRICK
author_sort Carle, PATRICK
title Polarimeter for an Accelerated Spheromak
title_short Polarimeter for an Accelerated Spheromak
title_full Polarimeter for an Accelerated Spheromak
title_fullStr Polarimeter for an Accelerated Spheromak
title_full_unstemmed Polarimeter for an Accelerated Spheromak
title_sort polarimeter for an accelerated spheromak
publishDate 2014
url http://hdl.handle.net/1974/12163
work_keys_str_mv AT carlepatrick polarimeterforanacceleratedspheromak
_version_ 1716666630458572800