Impact of photovoltaic generators and electric vehicles on a weak low voltage distribution grid

In this thesis, the behaviour of a weak power distribution grid at the Point of Common Coupling (PCC) in the presence of a Photovoltaic (PV) inverter and Electric Vehicles (EV) as loads is analyzed. The grid connected to PV and EV has high impedance. The impact at PCC when the injected power varies...

Full description

Bibliographic Details
Main Author: Gudivada, Venkata Thulasi Prasad
Language:English
Published: University of British Columbia 2013
Online Access:http://hdl.handle.net/2429/43810
id ndltd-LACETR-oai-collectionscanada.gc.ca-BVAU.2429-43810
record_format oai_dc
spelling ndltd-LACETR-oai-collectionscanada.gc.ca-BVAU.2429-438102014-03-26T03:39:11Z Impact of photovoltaic generators and electric vehicles on a weak low voltage distribution grid Gudivada, Venkata Thulasi Prasad In this thesis, the behaviour of a weak power distribution grid at the Point of Common Coupling (PCC) in the presence of a Photovoltaic (PV) inverter and Electric Vehicles (EV) as loads is analyzed. The grid connected to PV and EV has high impedance. The impact at PCC when the injected power varies in conjunction with the frequency and voltage deviation with a delay in inverter fed power is elaborated. Various measures such as peak shaving, coordinated charging, voltage drop correction have already been developed to mitigate the impact at PCC. These measures are observed on a combined EV and PV setup. In general, the grid tied inverter injects power based on an average grid voltage calculation at stable synchronization with the grid. If an error (for instance, an error in average grid voltage calculation) persists in such a case causing a loss in synchronization between the PV inverter and the grid, then a delay in the power injected may result in an oscillation at the PCC. A simple two bus system is considered to analyze the result of transportation delay. The delay and droop parameters of the PV inverter are altered whose results are quantitatively analyzed. The model abides the grid codes for active power reduction and static voltage support requirements. Further, the impact of a fault along with an inverter delay is analyzed. Simulative analysis is performed in the DIgSILENT PowerFactory software. To reduce the impact at PCC, performance criteria are analyzed whose parameters could be measured and altered. Scenarios are developed to analyze EV‟s impact in the presence and absence of storage and Distributed Generator (DG) that can be extended onto the micro grids. 2013-01-07T22:13:48Z 2013-07-07 2012 2013-01-07 2013-05 Electronic Thesis or Dissertation http://hdl.handle.net/2429/43810 eng University of British Columbia
collection NDLTD
language English
sources NDLTD
description In this thesis, the behaviour of a weak power distribution grid at the Point of Common Coupling (PCC) in the presence of a Photovoltaic (PV) inverter and Electric Vehicles (EV) as loads is analyzed. The grid connected to PV and EV has high impedance. The impact at PCC when the injected power varies in conjunction with the frequency and voltage deviation with a delay in inverter fed power is elaborated. Various measures such as peak shaving, coordinated charging, voltage drop correction have already been developed to mitigate the impact at PCC. These measures are observed on a combined EV and PV setup. In general, the grid tied inverter injects power based on an average grid voltage calculation at stable synchronization with the grid. If an error (for instance, an error in average grid voltage calculation) persists in such a case causing a loss in synchronization between the PV inverter and the grid, then a delay in the power injected may result in an oscillation at the PCC. A simple two bus system is considered to analyze the result of transportation delay. The delay and droop parameters of the PV inverter are altered whose results are quantitatively analyzed. The model abides the grid codes for active power reduction and static voltage support requirements. Further, the impact of a fault along with an inverter delay is analyzed. Simulative analysis is performed in the DIgSILENT PowerFactory software. To reduce the impact at PCC, performance criteria are analyzed whose parameters could be measured and altered. Scenarios are developed to analyze EV‟s impact in the presence and absence of storage and Distributed Generator (DG) that can be extended onto the micro grids.
author Gudivada, Venkata Thulasi Prasad
spellingShingle Gudivada, Venkata Thulasi Prasad
Impact of photovoltaic generators and electric vehicles on a weak low voltage distribution grid
author_facet Gudivada, Venkata Thulasi Prasad
author_sort Gudivada, Venkata Thulasi Prasad
title Impact of photovoltaic generators and electric vehicles on a weak low voltage distribution grid
title_short Impact of photovoltaic generators and electric vehicles on a weak low voltage distribution grid
title_full Impact of photovoltaic generators and electric vehicles on a weak low voltage distribution grid
title_fullStr Impact of photovoltaic generators and electric vehicles on a weak low voltage distribution grid
title_full_unstemmed Impact of photovoltaic generators and electric vehicles on a weak low voltage distribution grid
title_sort impact of photovoltaic generators and electric vehicles on a weak low voltage distribution grid
publisher University of British Columbia
publishDate 2013
url http://hdl.handle.net/2429/43810
work_keys_str_mv AT gudivadavenkatathulasiprasad impactofphotovoltaicgeneratorsandelectricvehiclesonaweaklowvoltagedistributiongrid
_version_ 1716656588085788672