Development and evaluation of an interface pressure transducer for biomedical applications

The measurement of the interface pressure between a biomedical device and part of the human body is useful to aid in the design or improve the performance and safety of such devices. Therefore, a need exists for a transducer to measure interface pressure in these applications. The development and...

Full description

Bibliographic Details
Main Author: Paris-Seeley, Nancy J.
Language:English
Published: 2009
Online Access:http://hdl.handle.net/2429/4103
id ndltd-LACETR-oai-collectionscanada.gc.ca-BVAU.2429-4103
record_format oai_dc
spelling ndltd-LACETR-oai-collectionscanada.gc.ca-BVAU.2429-41032014-03-14T15:39:24Z Development and evaluation of an interface pressure transducer for biomedical applications Paris-Seeley, Nancy J. The measurement of the interface pressure between a biomedical device and part of the human body is useful to aid in the design or improve the performance and safety of such devices. Therefore, a need exists for a transducer to measure interface pressure in these applications. The development and evaluation of an interface pressure transducer was the main goal of this research. Surgical retraction, surgical tourniquets and mammography were selected as demonstration applications for the developed transducer. These target applications were selected because they represented a wide spectrum of device and tissue characteristics and properties, and were in common use. A review of the available clinical, commercial and engineering literature identified a wide range of transducers and transducer technologies used for interface pressure measurement. The transducers included pneumatic/hydraulic, fibre-optic, strain based, capacitive and micromachined technologies. No standard method of measuring interface pressure was described and, in many cases, investigators cautioned against comparing-interface pressure measurements obtained using different measurement systems. From this review and an examination of the biomedical applications mentioned, the design criteria and optimal design specifications for an interface pressure transducer were defined. To gain a better understanding of the mechanical response of the interface between a device, transducer, and tissue to an applied loading, a preliminary finite element model was developed and studied. The model demonstrated the potential for shear stresses to develop between the transducer and interface materials. Furthermore a calibration system which simulated interface conditions was developed to evaluate both existing and developed transducers for use as interface pressure transducers. This evaluation demonstrated the lack of a transducer whose output was independent of the compliance of the interface materials. As well, an essential characteristic was identified for an effective interface pressure transducer that could be used in several applications where the interface material compliance was different. Based on the knowledge gained from the finite element analysis and existing transducer evaluation results, a novel interface pressure transducer was developed and evaluated both in the calibration system and via demonstration applications of surgical retraction and tourniquets. Under laboratory conditions in the calibration system, the transducer met many of the desired design specifications. The transducer was tested in the lab under both pneumatic and nonpneumatic tourniquet cuffs. The transducer worked well under the pneumatic cuff but required ] further development for use under the non-pneumatic cuff. The transducer was also integrated into a surgical retractor and evaluated in five clinical trials. It met many of the desired specifications for this application. 2009-02-02T23:43:59Z 2009-02-02T23:43:59Z 1996 2009-02-02T23:43:59Z 1996-11 Electronic Thesis or Dissertation http://hdl.handle.net/2429/4103 eng UBC Retrospective Theses Digitization Project [http://www.library.ubc.ca/archives/retro_theses/]
collection NDLTD
language English
sources NDLTD
description The measurement of the interface pressure between a biomedical device and part of the human body is useful to aid in the design or improve the performance and safety of such devices. Therefore, a need exists for a transducer to measure interface pressure in these applications. The development and evaluation of an interface pressure transducer was the main goal of this research. Surgical retraction, surgical tourniquets and mammography were selected as demonstration applications for the developed transducer. These target applications were selected because they represented a wide spectrum of device and tissue characteristics and properties, and were in common use. A review of the available clinical, commercial and engineering literature identified a wide range of transducers and transducer technologies used for interface pressure measurement. The transducers included pneumatic/hydraulic, fibre-optic, strain based, capacitive and micromachined technologies. No standard method of measuring interface pressure was described and, in many cases, investigators cautioned against comparing-interface pressure measurements obtained using different measurement systems. From this review and an examination of the biomedical applications mentioned, the design criteria and optimal design specifications for an interface pressure transducer were defined. To gain a better understanding of the mechanical response of the interface between a device, transducer, and tissue to an applied loading, a preliminary finite element model was developed and studied. The model demonstrated the potential for shear stresses to develop between the transducer and interface materials. Furthermore a calibration system which simulated interface conditions was developed to evaluate both existing and developed transducers for use as interface pressure transducers. This evaluation demonstrated the lack of a transducer whose output was independent of the compliance of the interface materials. As well, an essential characteristic was identified for an effective interface pressure transducer that could be used in several applications where the interface material compliance was different. Based on the knowledge gained from the finite element analysis and existing transducer evaluation results, a novel interface pressure transducer was developed and evaluated both in the calibration system and via demonstration applications of surgical retraction and tourniquets. Under laboratory conditions in the calibration system, the transducer met many of the desired design specifications. The transducer was tested in the lab under both pneumatic and nonpneumatic tourniquet cuffs. The transducer worked well under the pneumatic cuff but required ] further development for use under the non-pneumatic cuff. The transducer was also integrated into a surgical retractor and evaluated in five clinical trials. It met many of the desired specifications for this application.
author Paris-Seeley, Nancy J.
spellingShingle Paris-Seeley, Nancy J.
Development and evaluation of an interface pressure transducer for biomedical applications
author_facet Paris-Seeley, Nancy J.
author_sort Paris-Seeley, Nancy J.
title Development and evaluation of an interface pressure transducer for biomedical applications
title_short Development and evaluation of an interface pressure transducer for biomedical applications
title_full Development and evaluation of an interface pressure transducer for biomedical applications
title_fullStr Development and evaluation of an interface pressure transducer for biomedical applications
title_full_unstemmed Development and evaluation of an interface pressure transducer for biomedical applications
title_sort development and evaluation of an interface pressure transducer for biomedical applications
publishDate 2009
url http://hdl.handle.net/2429/4103
work_keys_str_mv AT parisseeleynancyj developmentandevaluationofaninterfacepressuretransducerforbiomedicalapplications
_version_ 1716650263048093696