Transient analysis of six-phase synchronous machines
Six-phase synchronous machines have been used in the past for high power generation, and presently are being used in high power electric drives and in ac and/or dc power supplies. This thesis presents a mathematical model for investigating the transient performance of a six-phase synchronous machine...
Main Author: | |
---|---|
Language: | English |
Published: |
2008
|
Online Access: | http://hdl.handle.net/2429/2381 |
Summary: | Six-phase synchronous machines have been used in the past for high power generation, and presently are being used in high power electric drives and in ac and/or dc power supplies. This thesis presents a mathematical model for investigating the transient performance of a six-phase synchronous machine, and develops a model for the simulation of such machines with the EMTP. The effect of the mutual leakage coupling between the two sets of three-phase stator windings are included in the development of a d-q equivalent circuit. The six-phase machine is constructed from a three-phase machine by splitting the stator windings into two equal three-phase sets. The six-phase machine reactances and resistances are derived by relating their values to the known three-phase machine values. The transient performance of the machine is tested by solving the machine equations for a case of a six-phase short-circuit at the terminals of the machine. The EMTP model presented is based on representing the six-phase machine as two three-phase machines in parallel. The EMTP model verification is achieved by comparing the EMTP results against an independent computer program, for the case of a six-phase short-circuit test at the terminals of the machine. |
---|