High temperature membrane bioreactor treating kraft evaporator condensate under steady and transient conditions

Research results from Bérubé (2000) have shown that the treatment of kraft evaporator condensate for reuse using a high temperature membrane bioreactor (MBR) is not only technically feasible, but can also be economically attractive. However, dynamics in daily operating conditions at kraft mills woul...

Full description

Bibliographic Details
Main Author: Jen, Ruey-chiu
Language:English
Published: 2009
Online Access:http://hdl.handle.net/2429/13714
id ndltd-LACETR-oai-collectionscanada.gc.ca-BVAU.2429-13714
record_format oai_dc
spelling ndltd-LACETR-oai-collectionscanada.gc.ca-BVAU.2429-137142014-03-14T15:46:54Z High temperature membrane bioreactor treating kraft evaporator condensate under steady and transient conditions Jen, Ruey-chiu Research results from Bérubé (2000) have shown that the treatment of kraft evaporator condensate for reuse using a high temperature membrane bioreactor (MBR) is not only technically feasible, but can also be economically attractive. However, dynamics in daily operating conditions at kraft mills would result in non-steady state loadings to such a treatment system. Hence, the influence of transient operating conditions on an MBR system requires investigation before the system could be considered for full-scale plants. Two bench-scale, high temperature MBRs (called RI for Reactor 1 and R2 for Reactor 2) were operated under conditions proposed by Bérubé (2000) to examine system performance under steady state operation. The operating parameters selected were as follows - 38-day sludge retention time (SRT), 9-hr hydraulic retention time (HRT), and evaporator condensate that contained 1,200 mg methanol /L. During the steady state experiment, the MBRs exhibited stable removal of the main contaminants. Removal efficiencies of 95 % for methanol and 64 % for organic components expressed as total organic carbon (TOC) were observed. Observed growth yields as low as 0.037 for RI and 0.025 for R2 were found. Effects of methanol shock loadings, black liquor spills, and pulp mill shutdown on a high temperature MBR treating condensate were the focus of the present research project. The reactors were subjected to four shock loadings to investigate long-term effects, and one shock loading to identify short-term effects. Results showed that the high temperature MBRs were reasonably stable and able to achieve the same removal efficiency when the load was increased by 1.5 and 2 times instantaneously. Overload of methanol was observed during the methanol shock loading test with 2.5 times the regular methanol concentration. However, the system recovered 4 hours after the short-term shock loadings, and two days after the long-term shock loadings. The MBRs started to shown inhibitory effects after the long-term black liquor carryover test with 8 mL black liquor per litre condensate. During the black liquor carryover test with 16 mL black liquor per litre condensate, methanol removal efficiency was greatly decreased and this negatively influenced TOC and chemical oxygen demand (COD) removal efficiencies. However, the system recovered 4 hours after the short-term shock loadings, and two days after the long-term shock loadings. During the tests, the colour of the MBR permeates remained relatively constant while the dissolved solids concentrations of the permeates increased slightly. Methanol, TOC, and COD utilization coefficients decreased during the shutdown period. However, the MBR system recovered along with resumption of loading fairly well. The MBR was capable of handling the 10-day shutdown period and recovered in 4 days to full capacity. No deleterious effects from 10-day shutdown were observed. 2009-10-07T20:41:34Z 2009-10-07T20:41:34Z 2002 2009-10-07T20:41:34Z 2002-11 Electronic Thesis or Dissertation http://hdl.handle.net/2429/13714 eng UBC Retrospective Theses Digitization Project [http://www.library.ubc.ca/archives/retro_theses/]
collection NDLTD
language English
sources NDLTD
description Research results from Bérubé (2000) have shown that the treatment of kraft evaporator condensate for reuse using a high temperature membrane bioreactor (MBR) is not only technically feasible, but can also be economically attractive. However, dynamics in daily operating conditions at kraft mills would result in non-steady state loadings to such a treatment system. Hence, the influence of transient operating conditions on an MBR system requires investigation before the system could be considered for full-scale plants. Two bench-scale, high temperature MBRs (called RI for Reactor 1 and R2 for Reactor 2) were operated under conditions proposed by Bérubé (2000) to examine system performance under steady state operation. The operating parameters selected were as follows - 38-day sludge retention time (SRT), 9-hr hydraulic retention time (HRT), and evaporator condensate that contained 1,200 mg methanol /L. During the steady state experiment, the MBRs exhibited stable removal of the main contaminants. Removal efficiencies of 95 % for methanol and 64 % for organic components expressed as total organic carbon (TOC) were observed. Observed growth yields as low as 0.037 for RI and 0.025 for R2 were found. Effects of methanol shock loadings, black liquor spills, and pulp mill shutdown on a high temperature MBR treating condensate were the focus of the present research project. The reactors were subjected to four shock loadings to investigate long-term effects, and one shock loading to identify short-term effects. Results showed that the high temperature MBRs were reasonably stable and able to achieve the same removal efficiency when the load was increased by 1.5 and 2 times instantaneously. Overload of methanol was observed during the methanol shock loading test with 2.5 times the regular methanol concentration. However, the system recovered 4 hours after the short-term shock loadings, and two days after the long-term shock loadings. The MBRs started to shown inhibitory effects after the long-term black liquor carryover test with 8 mL black liquor per litre condensate. During the black liquor carryover test with 16 mL black liquor per litre condensate, methanol removal efficiency was greatly decreased and this negatively influenced TOC and chemical oxygen demand (COD) removal efficiencies. However, the system recovered 4 hours after the short-term shock loadings, and two days after the long-term shock loadings. During the tests, the colour of the MBR permeates remained relatively constant while the dissolved solids concentrations of the permeates increased slightly. Methanol, TOC, and COD utilization coefficients decreased during the shutdown period. However, the MBR system recovered along with resumption of loading fairly well. The MBR was capable of handling the 10-day shutdown period and recovered in 4 days to full capacity. No deleterious effects from 10-day shutdown were observed.
author Jen, Ruey-chiu
spellingShingle Jen, Ruey-chiu
High temperature membrane bioreactor treating kraft evaporator condensate under steady and transient conditions
author_facet Jen, Ruey-chiu
author_sort Jen, Ruey-chiu
title High temperature membrane bioreactor treating kraft evaporator condensate under steady and transient conditions
title_short High temperature membrane bioreactor treating kraft evaporator condensate under steady and transient conditions
title_full High temperature membrane bioreactor treating kraft evaporator condensate under steady and transient conditions
title_fullStr High temperature membrane bioreactor treating kraft evaporator condensate under steady and transient conditions
title_full_unstemmed High temperature membrane bioreactor treating kraft evaporator condensate under steady and transient conditions
title_sort high temperature membrane bioreactor treating kraft evaporator condensate under steady and transient conditions
publishDate 2009
url http://hdl.handle.net/2429/13714
work_keys_str_mv AT jenrueychiu hightemperaturemembranebioreactortreatingkraftevaporatorcondensateundersteadyandtransientconditions
_version_ 1716652813262520320