Comparison of occlusal contacts on mounted dental models to contacts identified on digital 3D models using a new virtual alignment method

As 3D imaging of dental models becomes more common in clinical dentistry, the need for accurate images will increase. In order for these 3D models to be of greatest benefit, they will need to be aligned to accurately represent the given presentation of the individuals they represent. This is an im...

Full description

Bibliographic Details
Main Author: Straga, Robert William
Format: Others
Language:English
Published: University of British Columbia 2009
Online Access:http://hdl.handle.net/2429/6817
id ndltd-LACETR-oai-collectionscanada.gc.ca-BVAU.-6817
record_format oai_dc
spelling ndltd-LACETR-oai-collectionscanada.gc.ca-BVAU.-68172013-06-05T04:17:19ZComparison of occlusal contacts on mounted dental models to contacts identified on digital 3D models using a new virtual alignment methodStraga, Robert WilliamAs 3D imaging of dental models becomes more common in clinical dentistry, the need for accurate images will increase. In order for these 3D models to be of greatest benefit, they will need to be aligned to accurately represent the given presentation of the individuals they represent. This is an important step, since the acquisition of digital models results in two unrelated image files. This study evaluated a new technique for aligning 3D digital dental models using a 3D scan of the anterior teeth in occlusion of articulator mounted models as a “virtual bite registration.” Three-dimensional digital models of one set of epoxy dental models were created using a commercially available 3D laser scanner (Konica Minolta Vivid 910) and Geomagic software. Ten mountings of these same epoxy models were made, and a 3D scan of the anterior teeth in occlusion was made for each mounting. The 3D digital models were registered to the anterior 3D scan, and virtual occlusal contacts were recorded and compared to the actual occlusal contacts recorded on the epoxy models using shimstock and articulating film. Comparison of the new technique to the standards was made using sensitivity, specificity, positive predictive value and negative predictive value analyses. Specificity was high when using both shimstock and articulating film contacts as standards and digital contacts as tests, 0.97 and 0.98 respectively. When comparing the traditional methods of recording contacts to the new digital technique the sensitivity with shimstock as the standard was 0.63 and with articulating film as the standard the sensitivity was 0.54. Positive predictive value and negative predictive value of the digital technique compared to shimstock was 0.52 and 0.98 respectively. Compared to articulating paper the values were 0.76 and 0.96 respectively. Using a scan of the anterior teeth in occlusion as a virtual bite registration represents an appropriate method for aligning 3D digital dental models in an anatomically correct position. The technique described may represent a good technique for future comparison of the alignment of digital models to the alignment found on articulator mounted models or in the patient regardless of hardware and software being used.University of British Columbia2009-04-06T14:02:36Z2009-04-06T14:02:36Z20092009-04-06T14:02:36Z2009-05Electronic Thesis or Dissertation6293633 bytesapplication/pdfhttp://hdl.handle.net/2429/6817eng
collection NDLTD
language English
format Others
sources NDLTD
description As 3D imaging of dental models becomes more common in clinical dentistry, the need for accurate images will increase. In order for these 3D models to be of greatest benefit, they will need to be aligned to accurately represent the given presentation of the individuals they represent. This is an important step, since the acquisition of digital models results in two unrelated image files. This study evaluated a new technique for aligning 3D digital dental models using a 3D scan of the anterior teeth in occlusion of articulator mounted models as a “virtual bite registration.” Three-dimensional digital models of one set of epoxy dental models were created using a commercially available 3D laser scanner (Konica Minolta Vivid 910) and Geomagic software. Ten mountings of these same epoxy models were made, and a 3D scan of the anterior teeth in occlusion was made for each mounting. The 3D digital models were registered to the anterior 3D scan, and virtual occlusal contacts were recorded and compared to the actual occlusal contacts recorded on the epoxy models using shimstock and articulating film. Comparison of the new technique to the standards was made using sensitivity, specificity, positive predictive value and negative predictive value analyses. Specificity was high when using both shimstock and articulating film contacts as standards and digital contacts as tests, 0.97 and 0.98 respectively. When comparing the traditional methods of recording contacts to the new digital technique the sensitivity with shimstock as the standard was 0.63 and with articulating film as the standard the sensitivity was 0.54. Positive predictive value and negative predictive value of the digital technique compared to shimstock was 0.52 and 0.98 respectively. Compared to articulating paper the values were 0.76 and 0.96 respectively. Using a scan of the anterior teeth in occlusion as a virtual bite registration represents an appropriate method for aligning 3D digital dental models in an anatomically correct position. The technique described may represent a good technique for future comparison of the alignment of digital models to the alignment found on articulator mounted models or in the patient regardless of hardware and software being used.
author Straga, Robert William
spellingShingle Straga, Robert William
Comparison of occlusal contacts on mounted dental models to contacts identified on digital 3D models using a new virtual alignment method
author_facet Straga, Robert William
author_sort Straga, Robert William
title Comparison of occlusal contacts on mounted dental models to contacts identified on digital 3D models using a new virtual alignment method
title_short Comparison of occlusal contacts on mounted dental models to contacts identified on digital 3D models using a new virtual alignment method
title_full Comparison of occlusal contacts on mounted dental models to contacts identified on digital 3D models using a new virtual alignment method
title_fullStr Comparison of occlusal contacts on mounted dental models to contacts identified on digital 3D models using a new virtual alignment method
title_full_unstemmed Comparison of occlusal contacts on mounted dental models to contacts identified on digital 3D models using a new virtual alignment method
title_sort comparison of occlusal contacts on mounted dental models to contacts identified on digital 3d models using a new virtual alignment method
publisher University of British Columbia
publishDate 2009
url http://hdl.handle.net/2429/6817
work_keys_str_mv AT stragarobertwilliam comparisonofocclusalcontactsonmounteddentalmodelstocontactsidentifiedondigital3dmodelsusinganewvirtualalignmentmethod
_version_ 1716587006837915648