Using measures of external work to assess the degree of gait symmetry

It would be very helpful for researchers and clinicians if a single valid measure is developed to show objective differences or similarities among the gait patterns, not just through the able-bodied walkers population, but for any population with gait impairments in order to provide more objective g...

Full description

Bibliographic Details
Main Author: Moreno Hernández, Ana
Language:English
Published: University of British Columbia 2012
Online Access:http://hdl.handle.net/2429/43595
id ndltd-LACETR-oai-collectionscanada.gc.ca-BVAU.-43595
record_format oai_dc
spelling ndltd-LACETR-oai-collectionscanada.gc.ca-BVAU.-435952013-06-05T04:21:05ZUsing measures of external work to assess the degree of gait symmetryMoreno Hernández, AnaIt would be very helpful for researchers and clinicians if a single valid measure is developed to show objective differences or similarities among the gait patterns, not just through the able-bodied walkers population, but for any population with gait impairments in order to provide more objective gait evaluations to develop better rehabilitation protocols for improving pathological gait. Agrawal et al (2009) introduced the Symmetry in External (mechanical) Work (SEW) score, a measure expressed in percentage that quantifies the difference of work done by each limb during gait. The objective was to quantify kinetic differences in gait as a consequence of using different prosthetic feet in one patient. The limitations of this study were that just one patient was used, and this measure has not yet been validated in a non-amputee population. The first step in deciding whether this measure has value and validity requires that the SEW score be assessed in an able-bodied group. The purpose of this study was to compute the SEW score in a non-amputee population, analyzing a trial and day effect in the variation of this measurement. If validated then it could be introduced as a new tool for objectively measuring gait symmetry in different populations with gait impairments. Sixteen male participants between 23 and 35 years performed 10 successful walking trials through a measurement area where kinetic and kinematic data were recorded using a VICON 3D Motion Capture System and two force plates (AMTI and Bertec). SEW scores were calculated for each successful walking trial using the method described by Agrawal et al (2009). To assess the day effect participants returned to the laboratory one week later and repeated the same protocol. There was no significant interaction between the effects of trial and day (session) on SEW scores (F9,300=0.776, p=0.639) and it was concluded that the SEW score was a reliable, valid tool for measuring gait symmetry. When the SEW score was applied to a unilateral trans-tibial amputee participant, it was able to detect kinetic changes in gait resulting from differences in the designs of prosthetic feet.University of British Columbia2012-11-20T15:27:50Z2012-11-20T15:27:50Z20122012-11-202013-05Electronic Thesis or Dissertationhttp://hdl.handle.net/2429/43595eng
collection NDLTD
language English
sources NDLTD
description It would be very helpful for researchers and clinicians if a single valid measure is developed to show objective differences or similarities among the gait patterns, not just through the able-bodied walkers population, but for any population with gait impairments in order to provide more objective gait evaluations to develop better rehabilitation protocols for improving pathological gait. Agrawal et al (2009) introduced the Symmetry in External (mechanical) Work (SEW) score, a measure expressed in percentage that quantifies the difference of work done by each limb during gait. The objective was to quantify kinetic differences in gait as a consequence of using different prosthetic feet in one patient. The limitations of this study were that just one patient was used, and this measure has not yet been validated in a non-amputee population. The first step in deciding whether this measure has value and validity requires that the SEW score be assessed in an able-bodied group. The purpose of this study was to compute the SEW score in a non-amputee population, analyzing a trial and day effect in the variation of this measurement. If validated then it could be introduced as a new tool for objectively measuring gait symmetry in different populations with gait impairments. Sixteen male participants between 23 and 35 years performed 10 successful walking trials through a measurement area where kinetic and kinematic data were recorded using a VICON 3D Motion Capture System and two force plates (AMTI and Bertec). SEW scores were calculated for each successful walking trial using the method described by Agrawal et al (2009). To assess the day effect participants returned to the laboratory one week later and repeated the same protocol. There was no significant interaction between the effects of trial and day (session) on SEW scores (F9,300=0.776, p=0.639) and it was concluded that the SEW score was a reliable, valid tool for measuring gait symmetry. When the SEW score was applied to a unilateral trans-tibial amputee participant, it was able to detect kinetic changes in gait resulting from differences in the designs of prosthetic feet.
author Moreno Hernández, Ana
spellingShingle Moreno Hernández, Ana
Using measures of external work to assess the degree of gait symmetry
author_facet Moreno Hernández, Ana
author_sort Moreno Hernández, Ana
title Using measures of external work to assess the degree of gait symmetry
title_short Using measures of external work to assess the degree of gait symmetry
title_full Using measures of external work to assess the degree of gait symmetry
title_fullStr Using measures of external work to assess the degree of gait symmetry
title_full_unstemmed Using measures of external work to assess the degree of gait symmetry
title_sort using measures of external work to assess the degree of gait symmetry
publisher University of British Columbia
publishDate 2012
url http://hdl.handle.net/2429/43595
work_keys_str_mv AT morenohernandezana usingmeasuresofexternalworktoassessthedegreeofgaitsymmetry
_version_ 1716588431220408320