A saturation calibration of Hamamatsu’s multi-pixel photon counter

A relative calibration of the Fine-Grained Detector (FGD) in the T2K experiment is presented, with emphasis on the saturation calibration effects in Hamamatsu's multi-pixel photon counters (MPPCs). The calibration is produced on a test bed with a Hamamatsu Pico-Second Pulsed laser, on a small m...

Full description

Bibliographic Details
Main Author: Hastings, Simon Philip
Language:English
Published: University of British Columbia 2010
Online Access:http://hdl.handle.net/2429/27793
Description
Summary:A relative calibration of the Fine-Grained Detector (FGD) in the T2K experiment is presented, with emphasis on the saturation calibration effects in Hamamatsu's multi-pixel photon counters (MPPCs). The calibration is produced on a test bed with a Hamamatsu Pico-Second Pulsed laser, on a small model of the FGD on a sample of fibers and MPPCs. The wavelength shifting fiber-MPPC complex used in the FGD is found to have an effective pixel count of 518, and to exhibit an effective after-pulsing and crosstalk fraction of 1.6% when measured between 0.6 and 0.9 Volts over-voltage (V OV).