Computational Modelling of Biosensors of Complex Geometry

Biosensors are analytical devices mainly used to detect analytes and measure their concentrations. Mathematical modeling is widely used for optimizing and analyzing an operation of biosensors for reducing price of development of new biosensors. The object of this research is mathematical and compute...

Full description

Bibliographic Details
Main Author: Petrauskas, Karolis
Other Authors: Ivanauskas, Feliksas
Format: Doctoral Thesis
Language:English
Published: Lithuanian Academic Libraries Network (LABT) 2011
Subjects:
Online Access:http://vddb.laba.lt/fedora/get/LT-eLABa-0001:E.02~2011~D_20110701_105911-89480/DS.005.1.01.ETD
id ndltd-LABT_ETD-oai-elaba.lt-LT-eLABa-0001-E.02~2011~D_20110701_105911-89480
record_format oai_dc
spelling ndltd-LABT_ETD-oai-elaba.lt-LT-eLABa-0001-E.02~2011~D_20110701_105911-894802014-01-17T03:47:25Z2011-07-01engInformaticsPetrauskas, KarolisComputational Modelling of Biosensors of Complex GeometryKompiuterinis sudėtinės geometrijos biojutiklių modeliavimasLithuanian Academic Libraries Network (LABT)Biosensors are analytical devices mainly used to detect analytes and measure their concentrations. Mathematical modeling is widely used for optimizing and analyzing an operation of biosensors for reducing price of development of new biosensors. The object of this research is mathematical and computer models, describing an operation of biosensors, made of several parts with different properties. The dissertation covers models, formulated in one and two-dimensional spaces by partial differential equations with non-linear members, and solved numerically, using the method of finite differences. The numerical models are implemented by a computer program. An original mathematical model for a biosensor with a carbon nanotube electrode is presented in the dissertation. The conditions at which the one-dimensional mathematical model can be used instead of two-dimensional one for accurate prediction of the biosensor response are investigated. Elements, used to build models of biosensors with a complex structure, were systemized. The biosensor description language is proposed and the computer software, simulating an operation of biosensors in the one-dimensional space and a rectangular domain of the two-dimensional space, is developed. An adequateness of the model for the biosensor with the carbon nanotube electrode and the impact of structural and geometrical properties on a response of the biosensor were investigated, performing computer experiments using the developed software.Biojutikliai yra įrenginiai, skirti medžiagoms aptikti bei jų koncentracijoms matuoti. Siekiant sumažinti biojutiklių gamybos kaštus yra pasitelkiamas matematinis biojutikliuose vykstančių procesų modeliavimas. Disertacijoje nagrinėjami matematiniai ir kompiuteriniai biojutiklių modeliai, aprašantys biojutiklių, sudarytų iš kelių, skirtingas savybes turinčių dalių, veikimą. Nagrinėjami modeliai yra formuluojami vienmatėje bei dvimatėje erdvėse, aprašomi diferencialinėmis lygtimis dalinėmis išvestinėmis su netiesiniais nariais ir yra sprendžiami skaitiškai, naudojant baigtinių skirtumų metodą. Skaitiniai modeliai yra įgyvendinami kompiuterine programa. Disertacijoje pateikiamas originalus matematinis modelis biojutikliui su anglies nanovamzdelių elektrodu, nustatyti kriterijai, apibrėžiantys, kada biojutiklį su perforuota membrana galima modeliuoti vienmačiu modeliu. Darbe susisteminti elementai, naudojami biojutiklių modelių formulavimui, pagrindinį dėmesį skiriant biojutiklio struktūrinėms savybėms modeliuoti. Apibrėžta biojutiklių modelių aprašo kalba ir sukurta programinė įranga, leidžianti modeliuoti biojutiklių veikimą vienmačiais modeliais arba modeliais, formuluojamais stačiakampėje dvimatės erdvės srityje. Taikant sukurtą biojutiklių modeliavimo programinę įrangą, ištirtas biojutiklio su anglies nanovamzdelių elektrodu modelio adekvatumas ir struktūrinių bei geometrinių savybių įtaka biojutiklio elgsenai.BiosensorNumerical simulationComplex geometrySimulation softwareBiojutiklisSkaitinis modeliavimasSudėtinė geometrijaModeliavimo programinė įrangaDoctoral thesisIvanauskas, FeliksasKulvietis, GenadijusLaurinavičius, ValdasNavakauskas, DaliusSapagovas, Mifodijus Simutis, RimvydasVaicekauskas, RimantasBaronas, RomasVilnius UniversityVilnius Universityhttp://vddb.laba.lt/obj/LT-eLABa-0001:E.02~2011~D_20110701_105911-89480LT-eLABa-0001:E.02~2011~D_20110701_105911-89480VU-nmzbnfeowdr-20110601-222418http://vddb.laba.lt/fedora/get/LT-eLABa-0001:E.02~2011~D_20110701_105911-89480/DS.005.1.01.ETDUnrestrictedapplication/pdf
collection NDLTD
language English
format Doctoral Thesis
sources NDLTD
topic Informatics
Biosensor
Numerical simulation
Complex geometry
Simulation software
Biojutiklis
Skaitinis modeliavimas
Sudėtinė geometrija
Modeliavimo programinė įranga
spellingShingle Informatics
Biosensor
Numerical simulation
Complex geometry
Simulation software
Biojutiklis
Skaitinis modeliavimas
Sudėtinė geometrija
Modeliavimo programinė įranga
Petrauskas, Karolis
Computational Modelling of Biosensors of Complex Geometry
description Biosensors are analytical devices mainly used to detect analytes and measure their concentrations. Mathematical modeling is widely used for optimizing and analyzing an operation of biosensors for reducing price of development of new biosensors. The object of this research is mathematical and computer models, describing an operation of biosensors, made of several parts with different properties. The dissertation covers models, formulated in one and two-dimensional spaces by partial differential equations with non-linear members, and solved numerically, using the method of finite differences. The numerical models are implemented by a computer program. An original mathematical model for a biosensor with a carbon nanotube electrode is presented in the dissertation. The conditions at which the one-dimensional mathematical model can be used instead of two-dimensional one for accurate prediction of the biosensor response are investigated. Elements, used to build models of biosensors with a complex structure, were systemized. The biosensor description language is proposed and the computer software, simulating an operation of biosensors in the one-dimensional space and a rectangular domain of the two-dimensional space, is developed. An adequateness of the model for the biosensor with the carbon nanotube electrode and the impact of structural and geometrical properties on a response of the biosensor were investigated, performing computer experiments using the developed software. === Biojutikliai yra įrenginiai, skirti medžiagoms aptikti bei jų koncentracijoms matuoti. Siekiant sumažinti biojutiklių gamybos kaštus yra pasitelkiamas matematinis biojutikliuose vykstančių procesų modeliavimas. Disertacijoje nagrinėjami matematiniai ir kompiuteriniai biojutiklių modeliai, aprašantys biojutiklių, sudarytų iš kelių, skirtingas savybes turinčių dalių, veikimą. Nagrinėjami modeliai yra formuluojami vienmatėje bei dvimatėje erdvėse, aprašomi diferencialinėmis lygtimis dalinėmis išvestinėmis su netiesiniais nariais ir yra sprendžiami skaitiškai, naudojant baigtinių skirtumų metodą. Skaitiniai modeliai yra įgyvendinami kompiuterine programa. Disertacijoje pateikiamas originalus matematinis modelis biojutikliui su anglies nanovamzdelių elektrodu, nustatyti kriterijai, apibrėžiantys, kada biojutiklį su perforuota membrana galima modeliuoti vienmačiu modeliu. Darbe susisteminti elementai, naudojami biojutiklių modelių formulavimui, pagrindinį dėmesį skiriant biojutiklio struktūrinėms savybėms modeliuoti. Apibrėžta biojutiklių modelių aprašo kalba ir sukurta programinė įranga, leidžianti modeliuoti biojutiklių veikimą vienmačiais modeliais arba modeliais, formuluojamais stačiakampėje dvimatės erdvės srityje. Taikant sukurtą biojutiklių modeliavimo programinę įrangą, ištirtas biojutiklio su anglies nanovamzdelių elektrodu modelio adekvatumas ir struktūrinių bei geometrinių savybių įtaka biojutiklio elgsenai.
author2 Ivanauskas, Feliksas
author_facet Ivanauskas, Feliksas
Petrauskas, Karolis
author Petrauskas, Karolis
author_sort Petrauskas, Karolis
title Computational Modelling of Biosensors of Complex Geometry
title_short Computational Modelling of Biosensors of Complex Geometry
title_full Computational Modelling of Biosensors of Complex Geometry
title_fullStr Computational Modelling of Biosensors of Complex Geometry
title_full_unstemmed Computational Modelling of Biosensors of Complex Geometry
title_sort computational modelling of biosensors of complex geometry
publisher Lithuanian Academic Libraries Network (LABT)
publishDate 2011
url http://vddb.laba.lt/fedora/get/LT-eLABa-0001:E.02~2011~D_20110701_105911-89480/DS.005.1.01.ETD
work_keys_str_mv AT petrauskaskarolis computationalmodellingofbiosensorsofcomplexgeometry
AT petrauskaskarolis kompiuterinissudetinesgeometrijosbiojutikliumodeliavimas
_version_ 1716626359703306240