Comparação da distribuição de tensões em dois tipos de conexão protética de implantes com parafusos diferentes utilizando o método de análise por elementos finitos com modelo tridimensional
Made available in DSpace on 2011-12-27T14:14:25Z (GMT). No. of bitstreams: 2 000388162-0.pdf: 14806898 bytes, checksum: 307d9a5db880718206e03f9e7a7c7223 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) === The aim of this study was to compare and evaluate, through 3D fi...
Main Author: | |
---|---|
Other Authors: | |
Language: | Portuguese |
Published: |
Pontifícia Universidade Católica do Rio Grande do Sul
2011
|
Subjects: | |
Online Access: | http://hdl.handle.net/10923/505 |
id |
ndltd-IBICT-urn-repox.ist.utl.pt-RI_PUC_RS-oai-meriva.pucrs.br-10923-505 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-IBICT-urn-repox.ist.utl.pt-RI_PUC_RS-oai-meriva.pucrs.br-10923-5052018-05-23T23:49:59Z Comparação da distribuição de tensões em dois tipos de conexão protética de implantes com parafusos diferentes utilizando o método de análise por elementos finitos com modelo tridimensional Herbstrith Segundo, Regênio Mahfuz Oshima, Hugo Mitsuo Silva ODONTOLOGIA IMPLANTODONTIA MATERIAIS DENTÁRIOS MODELOS DENTÁRIOS RESISTÊNCIA DOS MATERIAIS (ODONTOLOGIA) Made available in DSpace on 2011-12-27T14:14:25Z (GMT). No. of bitstreams: 2 000388162-0.pdf: 14806898 bytes, checksum: 307d9a5db880718206e03f9e7a7c7223 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) The aim of this study was to compare and evaluate, through 3D finite element analysis, strain distribution generate by simulated loads over implants, abutments and metal ceramic crowns models in first molars region. The analysis were executed in four 3D models: model 1 and 2 with external butt joint, with gold and titanium abutment screw, respectively, model 2 and 3 with internal butt joint, with gold and titanium abutment screw, respectively, the standard load was 382N with two different angulations, 90º to occlusal surface and 15º to implant axis, and in two distinct points 4 and 6mm of the implant center, in ten different observation points on the implantabutment- screw set. The results suggested that in a general way, the internal butt joint models (3 and 4) showed a better mechanic behavior related to strain distribution along the implant-abutment-screw set. On the models 1 and 2, the abutment screw material had a great influence on the strain distribution. On the other hand, models 3 and 4 have no such behavior. O objetivo deste estudo foi avaliar e comparar qualitativamente, através de análise por elementos finitos com modelo 3D, a distribuição das tensões geradas por cargas simuladas sob modelos de implantes, pilares, coroas protéticas metalocerâmicas na região de primeiros molares. As análises foram executadas em 4 modelos tridimensionais: modelo 1 e modelo 2 com encaixe protético tipo hexágono externo e parafuso de pilar de ouro e titânio respectivamente, modelo 3 e modelo 4 com encaixe tipo hexágono interno e parafuso de pilar de ouro e titânio respectivamente, a carga aplicada foi padronizada em 382N com duas angulações diferentes, inclinações de 90º com a superfície oclusal e de 15º em relação ao longo eixo dos implantes, em dois pontos distintos, 4 e 6 mm do centro do implante, em 10 pontos diferentes de observação no conjunto implante-pilar-parafuso. Os resultados obtidos sugeriram que de uma maneira geral, os modelos com encaixe interno (3 e 4) possuem um melhor comportamento mecânico em relação a distribuição de tensões ao longo do complexo implante-pilar-parafuso. Nos modelos 1 e 2 o tipo de material que o parafuso de pilar é feito influencia na distribuição de tensões, por outro lado, nos modelos 3 e 4 isto não foi observado. 2011-12-27T14:14:25Z 2011-12-27T14:14:25Z 2006 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/masterThesis http://hdl.handle.net/10923/505 por info:eu-repo/semantics/openAccess Pontifícia Universidade Católica do Rio Grande do Sul Porto Alegre reponame:Repositório Institucional da PUC_RS instname:Pontifícia Universidade Católica do Rio Grande do Sul instacron:PUC_RS |
collection |
NDLTD |
language |
Portuguese |
sources |
NDLTD |
topic |
ODONTOLOGIA IMPLANTODONTIA MATERIAIS DENTÁRIOS MODELOS DENTÁRIOS RESISTÊNCIA DOS MATERIAIS (ODONTOLOGIA) |
spellingShingle |
ODONTOLOGIA IMPLANTODONTIA MATERIAIS DENTÁRIOS MODELOS DENTÁRIOS RESISTÊNCIA DOS MATERIAIS (ODONTOLOGIA) Herbstrith Segundo, Regênio Mahfuz Comparação da distribuição de tensões em dois tipos de conexão protética de implantes com parafusos diferentes utilizando o método de análise por elementos finitos com modelo tridimensional |
description |
Made available in DSpace on 2011-12-27T14:14:25Z (GMT). No. of bitstreams: 2
000388162-0.pdf: 14806898 bytes, checksum: 307d9a5db880718206e03f9e7a7c7223 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) === The aim of this study was to compare and evaluate, through 3D finite element analysis, strain distribution generate by simulated loads over implants, abutments and metal ceramic crowns models in first molars region. The analysis were executed in four 3D models: model 1 and 2 with external butt joint, with gold and titanium abutment screw, respectively, model 2 and 3 with internal butt joint, with gold and titanium abutment screw, respectively, the standard load was 382N with two different angulations, 90º to occlusal surface and 15º to implant axis, and in two distinct points 4 and 6mm of the implant center, in ten different observation points on the implantabutment- screw set. The results suggested that in a general way, the internal butt joint models (3 and 4) showed a better mechanic behavior related to strain distribution along the implant-abutment-screw set. On the models 1 and 2, the abutment screw material had a great influence on the strain distribution. On the other hand, models 3 and 4 have no such behavior. === O objetivo deste estudo foi avaliar e comparar qualitativamente, através de análise por elementos finitos com modelo 3D, a distribuição das tensões geradas por cargas simuladas sob modelos de implantes, pilares, coroas protéticas metalocerâmicas na região de primeiros molares. As análises foram executadas em 4 modelos tridimensionais: modelo 1 e modelo 2 com encaixe protético tipo hexágono externo e parafuso de pilar de ouro e titânio respectivamente, modelo 3 e modelo 4 com encaixe tipo hexágono interno e parafuso de pilar de ouro e titânio respectivamente, a carga aplicada foi padronizada em 382N com duas angulações diferentes, inclinações de 90º com a superfície oclusal e de 15º em relação ao longo eixo dos implantes, em dois pontos distintos, 4 e 6 mm do centro do implante, em 10 pontos diferentes de observação no conjunto implante-pilar-parafuso. Os resultados obtidos sugeriram que de uma maneira geral, os modelos com encaixe interno (3 e 4) possuem um melhor comportamento mecânico em relação a distribuição de tensões ao longo do complexo implante-pilar-parafuso. Nos modelos 1 e 2 o tipo de material que o parafuso de pilar é feito influencia na distribuição de tensões, por outro lado, nos modelos 3 e 4 isto não foi observado. |
author2 |
Oshima, Hugo Mitsuo Silva |
author_facet |
Oshima, Hugo Mitsuo Silva Herbstrith Segundo, Regênio Mahfuz |
author |
Herbstrith Segundo, Regênio Mahfuz |
author_sort |
Herbstrith Segundo, Regênio Mahfuz |
title |
Comparação da distribuição de tensões em dois tipos de conexão protética de implantes com parafusos diferentes utilizando o método de análise por elementos finitos com modelo tridimensional |
title_short |
Comparação da distribuição de tensões em dois tipos de conexão protética de implantes com parafusos diferentes utilizando o método de análise por elementos finitos com modelo tridimensional |
title_full |
Comparação da distribuição de tensões em dois tipos de conexão protética de implantes com parafusos diferentes utilizando o método de análise por elementos finitos com modelo tridimensional |
title_fullStr |
Comparação da distribuição de tensões em dois tipos de conexão protética de implantes com parafusos diferentes utilizando o método de análise por elementos finitos com modelo tridimensional |
title_full_unstemmed |
Comparação da distribuição de tensões em dois tipos de conexão protética de implantes com parafusos diferentes utilizando o método de análise por elementos finitos com modelo tridimensional |
title_sort |
comparação da distribuição de tensões em dois tipos de conexão protética de implantes com parafusos diferentes utilizando o método de análise por elementos finitos com modelo tridimensional |
publisher |
Pontifícia Universidade Católica do Rio Grande do Sul |
publishDate |
2011 |
url |
http://hdl.handle.net/10923/505 |
work_keys_str_mv |
AT herbstrithsegundoregeniomahfuz comparacaodadistribuicaodetensoesemdoistiposdeconexaoproteticadeimplantescomparafusosdiferentesutilizandoometododeanaliseporelementosfinitoscommodelotridimensional |
_version_ |
1718677395632816128 |