Desenvolvimento de um sistema de verificação da pressão arterial através do método oscilométrico

Made available in DSpace on 2013-08-07T18:53:44Z (GMT). No. of bitstreams: 1 000346861-Texto+Parcial-0.pdf: 1247028 bytes, checksum: 6cdf9feef272bc4395446fc3f7de312a (MD5) Previous issue date: 2006 === The verification of the blood pressure measure is of great importance for the cardiovascular dia...

Full description

Bibliographic Details
Main Author: Pereira, Léo Fabrício
Other Authors: Azevedo, Dario Francisco Guimarães de
Language:Portuguese
Published: Pontifícia Universidade Católica do Rio Grande do Sul 2013
Subjects:
Online Access:http://hdl.handle.net/10923/3232
id ndltd-IBICT-urn-repox.ist.utl.pt-RI_PUC_RS-oai-meriva.pucrs.br-10923-3232
record_format oai_dc
spelling ndltd-IBICT-urn-repox.ist.utl.pt-RI_PUC_RS-oai-meriva.pucrs.br-10923-32322018-05-23T23:54:47Z Desenvolvimento de um sistema de verificação da pressão arterial através do método oscilométrico Pereira, Léo Fabrício Azevedo, Dario Francisco Guimarães de ENGENHARIA ELÉTRICA ENGENHARIA ELETRÔNICA PRESSÃO SANGUÍNEA MEDIDORES DE PRESSÃO Made available in DSpace on 2013-08-07T18:53:44Z (GMT). No. of bitstreams: 1 000346861-Texto+Parcial-0.pdf: 1247028 bytes, checksum: 6cdf9feef272bc4395446fc3f7de312a (MD5) Previous issue date: 2006 The verification of the blood pressure measure is of great importance for the cardiovascular diagnosis and mainly for the attendance of therapeutic interventions however the invasive methods today used are expensive and mainly aggressive to the patient, reducing for his/her reasons application. This study intends to obtain, for non-invasive methods, the measure of the human patient's blood pressure. This consists of the acquisition of the systolic, diastolic and mean arterial blood pressures simultaneously as well as the presentation of these in a viewfinder. The acquired values using the non-invasive method will be compared to resulting data of the acquisition invasive of the blood pressure by catheter intra-aortic that pattern-gold is considered. The obtained signs by the non-invasive they will be conditioned directly in the computer after they be captured by an acquisition plate dose to the sensor that it is located in the cuff of the apparel. Already the obtained data in a conventional way will be located in a monitor which will also be transferred to the computer. A verificação da medida de pressão arterial é de grande importância para o diagnóstico de doenças cardiovasculares e principalmente para o acompanhamento de intervenções terapêuticas, porém os métodos invasivos hoje utilizados são caros e principalmente agressivos ao paciente, reduzindo por estes motivos sua aplicação. Este estudo pretende obter, por métodos não-invasivos, a medida da pressão arterial de pacientes humanos. Isto consiste na aquisição das pressões sistólicas, diastólicas e médias de forma "simultaneamente" bem como a apresentação destas num visor. Os valores adquiridos pelo método não-invasivo serão comparados a dados resultantes da aquisição invasiva da pressão arterial por carater intra-aórtico que é considerado padrão-ouro. Os sinais obtidos de maneira não-invasiva serão acondicionados diretamente no computador após serem captados por uma placa de aquisição junto ao sensor que está localizado no manguito do aparelho. Já os dados obtidos de maneira convencional estão localizados em um monitor os quais também serão transferidos para o computador. Este trabalho não tem como objetivo realizar testes em seres humanos. Assim, para validar o sistema proposto, serão realizados testes em pacientes virtuais com uma amostragem de dez medidas para diferentes níveis de pressão, tanto para o caso de “pacientes” adultos quanto para neonatais. 2013-08-07T18:53:44Z 2013-08-07T18:53:44Z 2006 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/masterThesis http://hdl.handle.net/10923/3232 por info:eu-repo/semantics/openAccess Pontifícia Universidade Católica do Rio Grande do Sul Porto Alegre reponame:Repositório Institucional da PUC_RS instname:Pontifícia Universidade Católica do Rio Grande do Sul instacron:PUC_RS
collection NDLTD
language Portuguese
sources NDLTD
topic ENGENHARIA ELÉTRICA
ENGENHARIA ELETRÔNICA
PRESSÃO SANGUÍNEA
MEDIDORES DE PRESSÃO
spellingShingle ENGENHARIA ELÉTRICA
ENGENHARIA ELETRÔNICA
PRESSÃO SANGUÍNEA
MEDIDORES DE PRESSÃO
Pereira, Léo Fabrício
Desenvolvimento de um sistema de verificação da pressão arterial através do método oscilométrico
description Made available in DSpace on 2013-08-07T18:53:44Z (GMT). No. of bitstreams: 1 000346861-Texto+Parcial-0.pdf: 1247028 bytes, checksum: 6cdf9feef272bc4395446fc3f7de312a (MD5) Previous issue date: 2006 === The verification of the blood pressure measure is of great importance for the cardiovascular diagnosis and mainly for the attendance of therapeutic interventions however the invasive methods today used are expensive and mainly aggressive to the patient, reducing for his/her reasons application. This study intends to obtain, for non-invasive methods, the measure of the human patient's blood pressure. This consists of the acquisition of the systolic, diastolic and mean arterial blood pressures simultaneously as well as the presentation of these in a viewfinder. The acquired values using the non-invasive method will be compared to resulting data of the acquisition invasive of the blood pressure by catheter intra-aortic that pattern-gold is considered. The obtained signs by the non-invasive they will be conditioned directly in the computer after they be captured by an acquisition plate dose to the sensor that it is located in the cuff of the apparel. Already the obtained data in a conventional way will be located in a monitor which will also be transferred to the computer. === A verificação da medida de pressão arterial é de grande importância para o diagnóstico de doenças cardiovasculares e principalmente para o acompanhamento de intervenções terapêuticas, porém os métodos invasivos hoje utilizados são caros e principalmente agressivos ao paciente, reduzindo por estes motivos sua aplicação. Este estudo pretende obter, por métodos não-invasivos, a medida da pressão arterial de pacientes humanos. Isto consiste na aquisição das pressões sistólicas, diastólicas e médias de forma "simultaneamente" bem como a apresentação destas num visor. Os valores adquiridos pelo método não-invasivo serão comparados a dados resultantes da aquisição invasiva da pressão arterial por carater intra-aórtico que é considerado padrão-ouro. Os sinais obtidos de maneira não-invasiva serão acondicionados diretamente no computador após serem captados por uma placa de aquisição junto ao sensor que está localizado no manguito do aparelho. Já os dados obtidos de maneira convencional estão localizados em um monitor os quais também serão transferidos para o computador. Este trabalho não tem como objetivo realizar testes em seres humanos. Assim, para validar o sistema proposto, serão realizados testes em pacientes virtuais com uma amostragem de dez medidas para diferentes níveis de pressão, tanto para o caso de “pacientes” adultos quanto para neonatais.
author2 Azevedo, Dario Francisco Guimarães de
author_facet Azevedo, Dario Francisco Guimarães de
Pereira, Léo Fabrício
author Pereira, Léo Fabrício
author_sort Pereira, Léo Fabrício
title Desenvolvimento de um sistema de verificação da pressão arterial através do método oscilométrico
title_short Desenvolvimento de um sistema de verificação da pressão arterial através do método oscilométrico
title_full Desenvolvimento de um sistema de verificação da pressão arterial através do método oscilométrico
title_fullStr Desenvolvimento de um sistema de verificação da pressão arterial através do método oscilométrico
title_full_unstemmed Desenvolvimento de um sistema de verificação da pressão arterial através do método oscilométrico
title_sort desenvolvimento de um sistema de verificação da pressão arterial através do método oscilométrico
publisher Pontifícia Universidade Católica do Rio Grande do Sul
publishDate 2013
url http://hdl.handle.net/10923/3232
work_keys_str_mv AT pereiraleofabricio desenvolvimentodeumsistemadeverificacaodapressaoarterialatravesdometodooscilometrico
_version_ 1718678068877328384