Modelling and methodology apllied to evaluate multi-infeed performance of HVDC transmission systems.

The Brazilian transmission system covers a large area, with a high concentration of consumer centres in the Southeast region and abundant hydro generation in the North. To connect these regions, some of the transmission lines might reach 2500 km length, creating a challenging situation. In this...

Full description

Bibliographic Details
Main Author: Felipe Rocha Velloso de Almeida Pedroso
Other Authors: Silvio Giuseppe Di Santo
Language:English
Published: Universidade de São Paulo 2017
Subjects:
LCC
Online Access:http://www.teses.usp.br/teses/disponiveis/3/3143/tde-27042018-092616/
id ndltd-IBICT-oai-teses.usp.br-tde-27042018-092616
record_format oai_dc
collection NDLTD
language English
sources NDLTD
topic Ângulo de extinção
Compensador síncrono
Falha
Transmissão de energia elétrica
Commutation failure
Extinction angle
HVDC
LCC
Multi-infeed
Statcom
Synchronous condenser
spellingShingle Ângulo de extinção
Compensador síncrono
Falha
Transmissão de energia elétrica
Commutation failure
Extinction angle
HVDC
LCC
Multi-infeed
Statcom
Synchronous condenser
Felipe Rocha Velloso de Almeida Pedroso
Modelling and methodology apllied to evaluate multi-infeed performance of HVDC transmission systems.
description The Brazilian transmission system covers a large area, with a high concentration of consumer centres in the Southeast region and abundant hydro generation in the North. To connect these regions, some of the transmission lines might reach 2500 km length, creating a challenging situation. In this context, system planners have been defining the use of HVDC systems as the most feasible choice of transmission investment. It is so, recognized that the connections of power plants in the Northern region to the load centres in the Southeast will require a significant number of bipoles and, until the present moment, all the operational and planned HVDC lines are based on the converter technology known as LCC (Line Commutated Converter) and consequently subject to commutation failure. Currently, the Brazilian system has four LCC bipoles, with two other bipoles under construction. Although the Southeast grid is strong, the connection of two additional bipoles is a concern as the interaction between these inverters may cause strong effects on one another, a phenomenon known as multi-infeed interaction. In such a situation, the assessment of the system operation, possible outages and possible mitigation methods are of paramount importance. This document presents a different methodology for the analysis of the multi-infeed system mentioned and focuses on its validation by analysing operation under normal conditions and with the implementation of established mitigation methods. The investigation was carried out with EMT, power flow, short-circuit and electromechanical softwares in a very large AC system composed by 100 buses on EMT and full Brazilian system on the rest. The effects of faults were analysed and the areas containing the buses where a fault leads to multiple commutation failures were identified. === O sistema de brasileiro de transmissão abrange uma área ampla, com uma alta concentração de consumo na região Sudeste e abundante geração hidrelétrica no Norte. Para conectar essas regiões, algumas das linhas de transmissão podem alcançar comprimentos de 2500 km, criando uma situação desafiadora. Neste contexto, os planejadores de sistemas têm definido o uso de sistemas HVDC como a escolha mais viável de investimento em transmissão. É então reconhecido que as conexões de usinas na região Norte aos centros consumidores no Sudeste exigirão um número significativo de bipolos e, até o momento presente, todas as linhas HVDC operacionais e planejadas são baseadas na tecnologia de conversão conhecida como LCC (Line Commutated Converter) e consequentemente sujeito a falha de comutação. Atualmente, o sistema brasileiro tem quatro bipolos LCC, com outros dois bipolos em construção. Embora a rede do Sudeste seja considerada forte, a conexão de dois bipolos adicionais é uma preocupação, pois a interação entre esses inversores pode causar efeitos danosos uns sobre os outros, um fenômeno conhecido como interação multi-infeed. Em tal situação, a avaliação da operação do sistema, possíveis interrupções e possíveis métodos de mitigação são de suma importância. Este documento apresenta uma metodologia diferente para a análise do sistema multi-infeed mencionado e foca em sua validação, analisando a operação em condições normais e com a implementação de métodos de mitigação conhecidos. A investigação foi realizada com softwares EMT, de curto circuito, fluxo de potência e estabilidade eletromecância em um sistema CA muito grande composto por 100 barras em EMT e sistema brasileiro completo no resto. Os efeitos das falhas foram analisados e as áreas que contêm as barras onde uma falha leva a múltiplas falhas de comutação foram identificadas.
author2 Silvio Giuseppe Di Santo
author_facet Silvio Giuseppe Di Santo
Felipe Rocha Velloso de Almeida Pedroso
author Felipe Rocha Velloso de Almeida Pedroso
author_sort Felipe Rocha Velloso de Almeida Pedroso
title Modelling and methodology apllied to evaluate multi-infeed performance of HVDC transmission systems.
title_short Modelling and methodology apllied to evaluate multi-infeed performance of HVDC transmission systems.
title_full Modelling and methodology apllied to evaluate multi-infeed performance of HVDC transmission systems.
title_fullStr Modelling and methodology apllied to evaluate multi-infeed performance of HVDC transmission systems.
title_full_unstemmed Modelling and methodology apllied to evaluate multi-infeed performance of HVDC transmission systems.
title_sort modelling and methodology apllied to evaluate multi-infeed performance of hvdc transmission systems.
publisher Universidade de São Paulo
publishDate 2017
url http://www.teses.usp.br/teses/disponiveis/3/3143/tde-27042018-092616/
work_keys_str_mv AT feliperochavellosodealmeidapedroso modellingandmethodologyaplliedtoevaluatemultiinfeedperformanceofhvdctransmissionsystems
AT feliperochavellosodealmeidapedroso modelagememetodologiaaplicadasaavaliacaodaperformancedesistemasmultinfeeddetransmissaohvdc
_version_ 1718920602130055168
spelling ndltd-IBICT-oai-teses.usp.br-tde-27042018-0926162019-01-22T00:23:15Z Modelling and methodology apllied to evaluate multi-infeed performance of HVDC transmission systems. Modelagem e metodologia aplicadas a avaliação da performance de sistemas mult-infeed de transmissão HVDC. Felipe Rocha Velloso de Almeida Pedroso Silvio Giuseppe Di Santo José Antonio Jardini Ricardo León Vasquez Arnez Fabiana Aparecida de Toledo Silva Ângulo de extinção Compensador síncrono Falha Transmissão de energia elétrica Commutation failure Extinction angle HVDC LCC Multi-infeed Statcom Synchronous condenser The Brazilian transmission system covers a large area, with a high concentration of consumer centres in the Southeast region and abundant hydro generation in the North. To connect these regions, some of the transmission lines might reach 2500 km length, creating a challenging situation. In this context, system planners have been defining the use of HVDC systems as the most feasible choice of transmission investment. It is so, recognized that the connections of power plants in the Northern region to the load centres in the Southeast will require a significant number of bipoles and, until the present moment, all the operational and planned HVDC lines are based on the converter technology known as LCC (Line Commutated Converter) and consequently subject to commutation failure. Currently, the Brazilian system has four LCC bipoles, with two other bipoles under construction. Although the Southeast grid is strong, the connection of two additional bipoles is a concern as the interaction between these inverters may cause strong effects on one another, a phenomenon known as multi-infeed interaction. In such a situation, the assessment of the system operation, possible outages and possible mitigation methods are of paramount importance. This document presents a different methodology for the analysis of the multi-infeed system mentioned and focuses on its validation by analysing operation under normal conditions and with the implementation of established mitigation methods. The investigation was carried out with EMT, power flow, short-circuit and electromechanical softwares in a very large AC system composed by 100 buses on EMT and full Brazilian system on the rest. The effects of faults were analysed and the areas containing the buses where a fault leads to multiple commutation failures were identified. O sistema de brasileiro de transmissão abrange uma área ampla, com uma alta concentração de consumo na região Sudeste e abundante geração hidrelétrica no Norte. Para conectar essas regiões, algumas das linhas de transmissão podem alcançar comprimentos de 2500 km, criando uma situação desafiadora. Neste contexto, os planejadores de sistemas têm definido o uso de sistemas HVDC como a escolha mais viável de investimento em transmissão. É então reconhecido que as conexões de usinas na região Norte aos centros consumidores no Sudeste exigirão um número significativo de bipolos e, até o momento presente, todas as linhas HVDC operacionais e planejadas são baseadas na tecnologia de conversão conhecida como LCC (Line Commutated Converter) e consequentemente sujeito a falha de comutação. Atualmente, o sistema brasileiro tem quatro bipolos LCC, com outros dois bipolos em construção. Embora a rede do Sudeste seja considerada forte, a conexão de dois bipolos adicionais é uma preocupação, pois a interação entre esses inversores pode causar efeitos danosos uns sobre os outros, um fenômeno conhecido como interação multi-infeed. Em tal situação, a avaliação da operação do sistema, possíveis interrupções e possíveis métodos de mitigação são de suma importância. Este documento apresenta uma metodologia diferente para a análise do sistema multi-infeed mencionado e foca em sua validação, analisando a operação em condições normais e com a implementação de métodos de mitigação conhecidos. A investigação foi realizada com softwares EMT, de curto circuito, fluxo de potência e estabilidade eletromecância em um sistema CA muito grande composto por 100 barras em EMT e sistema brasileiro completo no resto. Os efeitos das falhas foram analisados e as áreas que contêm as barras onde uma falha leva a múltiplas falhas de comutação foram identificadas. 2017-08-30 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/masterThesis http://www.teses.usp.br/teses/disponiveis/3/3143/tde-27042018-092616/ eng info:eu-repo/semantics/openAccess Universidade de São Paulo Engenharia Elétrica USP BR reponame:Biblioteca Digital de Teses e Dissertações da USP instname:Universidade de São Paulo instacron:USP