Topics in design and analysis of transcutaneous energy transfer to ventricular assist devices.
This research studies a Transcutaneous Energy Transfer (TET) system which uses electromagnetic fields to transfer power from outside the body to an artificial organ (AO) in the body. It works like a high frequency transformer whereas the skin is part of the magnetic coupling between the primary...
Main Author: | |
---|---|
Other Authors: | |
Language: | English |
Published: |
Universidade de São Paulo
2013
|
Subjects: | |
Online Access: | http://www.teses.usp.br/teses/disponiveis/3/3143/tde-10072014-160024/ |
id |
ndltd-IBICT-oai-teses.usp.br-tde-10072014-160024 |
---|---|
record_format |
oai_dc |
collection |
NDLTD |
language |
English |
sources |
NDLTD |
topic |
Eletromagnetismo
Método dos Elementos Finitos Otimização Transmissão Transcutânea de Energia Electromagnetism Finite Element Method Optimization Transcutaneous Energy Transmission |
spellingShingle |
Eletromagnetismo
Método dos Elementos Finitos Otimização Transmissão Transcutânea de Energia Electromagnetism Finite Element Method Optimization Transcutaneous Energy Transmission Daniela Wolter Ferreira Topics in design and analysis of transcutaneous energy transfer to ventricular assist devices. |
description |
This research studies a Transcutaneous Energy Transfer (TET) system which uses electromagnetic fields to transfer power from outside the body to an artificial organ (AO) in the body. It works like a high frequency transformer whereas the skin is part of the magnetic coupling between the primary (external) and secondary (internal) coils. Thus, the external coil (transmitter), which is excited by an oscillator circuit that transforms the continuous (DC) voltage to high-frequency alternating (AC) voltage, transfers energy to an internal system (receiver) containing a coil associated with a rectifier-regulator circuit to supply power to the AO and an internal rechargeable battery. Due to the diversity of research areas in TET systems, this thesis focused mainly on the TET coils, exploring few aspects of the electronic circuits which directly affect the proper design of the coils. Simulations of different configurations of coils (with different magnetic material types and different core geometrical dimensions) and different electrical parameters were performed via Finite Element Method (FEM) applications. Analyses of the results of these simulations with and without serial resonant capacitors (SRCs) observed the behavior of the coils considering the efficiency, regulation, specific absorption rate (SAR) and current density induced in the skin. These results also facilitated an optimization procedure using Kriging method without the need for new simulations via FEM. In parallel with the optimization procedure, different physical prototypes were created and tested to validate the simulations and explore the behavior of the coils. The temperature increase of the coils and the threshold limits of the electronic circuits were observed, suggesting new optimization strategies. Since the computation of the temperature is too complicated, the temperature rise was indirectly considered in this research by the use of a factor called thermo factor, which represents the relationship between the dissipated power and the area of the coil. Moreover, since the AO requires a constant power, the load of the TET system was modeled as a variable resistance. This thesis proposed an algorithm to compute this value of the variable resistance directly in the FEM simulations. Thus, another optimization procedure was proposed with the new mentioned strategy by directly interacting with the FEM application. In this second case, homogenization methods were used to simplify the mesh without neglecting eddy current, proximity and skin effects, thus allowing accurate simulations of coils with thicker wire gauges and at higher frequencies. In the end, the results of both simulations were briefly discussed to evaluate configurations eligible for construction or assembly.
===
Esse trabalho estuda um sistema de transferência de energia transcutâneo (TET) que, tal qual um transformador de alta freqüência, usa campos eletromagnéticos para transferir potência de fora do corpo a um órgão artificial dentro do corpo. Assim, a pele passa a ser parte do acoplamento magnético entre o primário (bobina externa) e o secundário (bobina interna). Dessa forma, a bobina externa (transmissor) é excitada por um circuito oscilador, gerando corrente alternada de alta freqüência e transfere energia ao sistema secundário interno (receptor) que contém uma bobina associada a um circuito retificador seguido de amplificadores e reguladores para alimentar o órgão artificial e/ou uma bateria recarregável interna. Devido à diversidade de áreas para pesquisar, esta tese teve as bobinas de TET como objetivo principal, explorando alguns aspectos dos circuitos eletrônicos que afetam diretamente o projeto adequado das bobinas. Simulações de diferentes configurações de bobinas (com diferentes tipos de material magnético e diferentes dimensões geométricas dos núcleos) e diferentes parâmetros elétricos foram realizados através de softwares de Método dos Elementos Finitos (FEM). Essas análises com e sem capacitores de ressonância série (SRCs) observaram o comportamento das bobinas considerando o rendimento, a regulação, a taxa de absorção específica (SAR) e densidade de corrente induzida na pele. Os resultados dessas simulações também facilitou um procedimento de otimização usando o método de Kriging, sem a necessidade de novas simulações via FEM. Em paralelo com o processo de optimização, diferentes protótipos físicos foram criados e testados para validar as simulações e explorar o comportamento das bobinas. O aumento da temperatura nas bobinas e os limites dos circuitos eletrônicos foram observados, sugerindo novas estratégias de otimização. Uma vez que o cálculo da temperatura é demasiado complicado, esta pesquisa sugere o uso de um fator, aqui denominado \"fator térmico\", para indiretamente considerar esse aumento de temperatura. Além disso, uma vez que o AO requer uma potência constante, a carga do transformador de TET foi modelada como uma resistência variável. Esta tese propõe um algoritmo para calcular este valor de resistência variável diretamente nas simulações com FEM. Assim, foi proposto um outro procedimento de otimização com a nova estratégia mencionada, interagindo diretamente com a aplicação de FEM. Neste segundo caso, os métodos de homogeneização foram utilizados para simplificar a malha sem ignorar correntes de Foucault, e os efeitos pelicular e de proximidade, permitindo simulações precisas de bobinas com fios mais grossos e em frequências mais altas. Os resultados de ambas as simulações foram discutidos brevemente no final para avaliar configurações elegíveis para serem montadas.
|
author2 |
Luiz Lebensztajn |
author_facet |
Luiz Lebensztajn Daniela Wolter Ferreira |
author |
Daniela Wolter Ferreira |
author_sort |
Daniela Wolter Ferreira |
title |
Topics in design and analysis of transcutaneous energy transfer to ventricular assist devices.
|
title_short |
Topics in design and analysis of transcutaneous energy transfer to ventricular assist devices.
|
title_full |
Topics in design and analysis of transcutaneous energy transfer to ventricular assist devices.
|
title_fullStr |
Topics in design and analysis of transcutaneous energy transfer to ventricular assist devices.
|
title_full_unstemmed |
Topics in design and analysis of transcutaneous energy transfer to ventricular assist devices.
|
title_sort |
topics in design and analysis of transcutaneous energy transfer to ventricular assist devices. |
publisher |
Universidade de São Paulo |
publishDate |
2013 |
url |
http://www.teses.usp.br/teses/disponiveis/3/3143/tde-10072014-160024/ |
work_keys_str_mv |
AT danielawolterferreira topicsindesignandanalysisoftranscutaneousenergytransfertoventricularassistdevices AT danielawolterferreira topicosdeprojetoeanalisedetransferenciadeenergiatranscutaneaparadispositivosdeassistenciaventricular |
_version_ |
1718921679261925376 |
spelling |
ndltd-IBICT-oai-teses.usp.br-tde-10072014-1600242019-01-22T00:28:24Z Topics in design and analysis of transcutaneous energy transfer to ventricular assist devices. Tópicos de projeto e análise de transferência de energia transcutânea para dispositivos de assistência ventricular. Daniela Wolter Ferreira Luiz Lebensztajn Aron José Pazin de Andrade Laurent François Krähenbühl Florent Morel Carlos Antonio França Sartori Eletromagnetismo Método dos Elementos Finitos Otimização Transmissão Transcutânea de Energia Electromagnetism Finite Element Method Optimization Transcutaneous Energy Transmission This research studies a Transcutaneous Energy Transfer (TET) system which uses electromagnetic fields to transfer power from outside the body to an artificial organ (AO) in the body. It works like a high frequency transformer whereas the skin is part of the magnetic coupling between the primary (external) and secondary (internal) coils. Thus, the external coil (transmitter), which is excited by an oscillator circuit that transforms the continuous (DC) voltage to high-frequency alternating (AC) voltage, transfers energy to an internal system (receiver) containing a coil associated with a rectifier-regulator circuit to supply power to the AO and an internal rechargeable battery. Due to the diversity of research areas in TET systems, this thesis focused mainly on the TET coils, exploring few aspects of the electronic circuits which directly affect the proper design of the coils. Simulations of different configurations of coils (with different magnetic material types and different core geometrical dimensions) and different electrical parameters were performed via Finite Element Method (FEM) applications. Analyses of the results of these simulations with and without serial resonant capacitors (SRCs) observed the behavior of the coils considering the efficiency, regulation, specific absorption rate (SAR) and current density induced in the skin. These results also facilitated an optimization procedure using Kriging method without the need for new simulations via FEM. In parallel with the optimization procedure, different physical prototypes were created and tested to validate the simulations and explore the behavior of the coils. The temperature increase of the coils and the threshold limits of the electronic circuits were observed, suggesting new optimization strategies. Since the computation of the temperature is too complicated, the temperature rise was indirectly considered in this research by the use of a factor called thermo factor, which represents the relationship between the dissipated power and the area of the coil. Moreover, since the AO requires a constant power, the load of the TET system was modeled as a variable resistance. This thesis proposed an algorithm to compute this value of the variable resistance directly in the FEM simulations. Thus, another optimization procedure was proposed with the new mentioned strategy by directly interacting with the FEM application. In this second case, homogenization methods were used to simplify the mesh without neglecting eddy current, proximity and skin effects, thus allowing accurate simulations of coils with thicker wire gauges and at higher frequencies. In the end, the results of both simulations were briefly discussed to evaluate configurations eligible for construction or assembly. Esse trabalho estuda um sistema de transferência de energia transcutâneo (TET) que, tal qual um transformador de alta freqüência, usa campos eletromagnéticos para transferir potência de fora do corpo a um órgão artificial dentro do corpo. Assim, a pele passa a ser parte do acoplamento magnético entre o primário (bobina externa) e o secundário (bobina interna). Dessa forma, a bobina externa (transmissor) é excitada por um circuito oscilador, gerando corrente alternada de alta freqüência e transfere energia ao sistema secundário interno (receptor) que contém uma bobina associada a um circuito retificador seguido de amplificadores e reguladores para alimentar o órgão artificial e/ou uma bateria recarregável interna. Devido à diversidade de áreas para pesquisar, esta tese teve as bobinas de TET como objetivo principal, explorando alguns aspectos dos circuitos eletrônicos que afetam diretamente o projeto adequado das bobinas. Simulações de diferentes configurações de bobinas (com diferentes tipos de material magnético e diferentes dimensões geométricas dos núcleos) e diferentes parâmetros elétricos foram realizados através de softwares de Método dos Elementos Finitos (FEM). Essas análises com e sem capacitores de ressonância série (SRCs) observaram o comportamento das bobinas considerando o rendimento, a regulação, a taxa de absorção específica (SAR) e densidade de corrente induzida na pele. Os resultados dessas simulações também facilitou um procedimento de otimização usando o método de Kriging, sem a necessidade de novas simulações via FEM. Em paralelo com o processo de optimização, diferentes protótipos físicos foram criados e testados para validar as simulações e explorar o comportamento das bobinas. O aumento da temperatura nas bobinas e os limites dos circuitos eletrônicos foram observados, sugerindo novas estratégias de otimização. Uma vez que o cálculo da temperatura é demasiado complicado, esta pesquisa sugere o uso de um fator, aqui denominado \"fator térmico\", para indiretamente considerar esse aumento de temperatura. Além disso, uma vez que o AO requer uma potência constante, a carga do transformador de TET foi modelada como uma resistência variável. Esta tese propõe um algoritmo para calcular este valor de resistência variável diretamente nas simulações com FEM. Assim, foi proposto um outro procedimento de otimização com a nova estratégia mencionada, interagindo diretamente com a aplicação de FEM. Neste segundo caso, os métodos de homogeneização foram utilizados para simplificar a malha sem ignorar correntes de Foucault, e os efeitos pelicular e de proximidade, permitindo simulações precisas de bobinas com fios mais grossos e em frequências mais altas. Os resultados de ambas as simulações foram discutidos brevemente no final para avaliar configurações elegíveis para serem montadas. 2013-09-06 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/doctoralThesis http://www.teses.usp.br/teses/disponiveis/3/3143/tde-10072014-160024/ eng info:eu-repo/semantics/openAccess Universidade de São Paulo Engenharia Elétrica USP BR reponame:Biblioteca Digital de Teses e Dissertações da USP instname:Universidade de São Paulo instacron:USP |