Avalia??o da potencialidade no re?so dom?stico da ?gua cinza tratada para fins n?o pot?veis

Submitted by Verena Pereira (verenagoncalves@uefs.br) on 2018-07-16T21:36:33Z No. of bitstreams: 1 Disserta??o SILVA, 2018.pdf: 2779443 bytes, checksum: 40c836b0d66d471baa3bbcd33b9d4b10 (MD5) === Made available in DSpace on 2018-07-16T21:36:33Z (GMT). No. of bitstreams: 1 Disserta??o SILVA, 2018....

Full description

Bibliographic Details
Main Author: Silva Neto, Hamilton de Ara?jo
Other Authors: Silva, Eduardo Henrique Borges Cohim
Format: Others
Language:Portuguese
Published: Universidade Estadual de Feira de Santana 2018
Subjects:
Online Access:http://tede2.uefs.br:8080/handle/tede/666
Description
Summary:Submitted by Verena Pereira (verenagoncalves@uefs.br) on 2018-07-16T21:36:33Z No. of bitstreams: 1 Disserta??o SILVA, 2018.pdf: 2779443 bytes, checksum: 40c836b0d66d471baa3bbcd33b9d4b10 (MD5) === Made available in DSpace on 2018-07-16T21:36:33Z (GMT). No. of bitstreams: 1 Disserta??o SILVA, 2018.pdf: 2779443 bytes, checksum: 40c836b0d66d471baa3bbcd33b9d4b10 (MD5) Previous issue date: 2018-03-01 === Treatment and reuse of gray water (GW) has been studied as an alternative for non-potable uses. The objective of this study was to evaluate the potential for reuse of treated gray water (TGW) in a high standard residence in Feira de Santana ? BA. The microbiological risk for TGW use was assessed via the methodology Quantitative Microbial Risk Assessment (QMRA); the potential for generating bad odors by means of pH, DO and ORP measurements; the color was measured directly; and the embodied energy using the methodology of Life Cicle Assessment LCA. The average microbiological risk of TWG was of the order of 10-5 DALY.pppa-1. The ACT also presented ow potential for generating bad odors. The measured color was on average 13.5HU, with a standard deviation of 10 uH. The system?s embodied energy found was 2.74 kWh/m? of TGW produced, lower than the local concessionaire numbers. The gray water (GW) is found to have great potential for less noble reuse purposes === O tratamento e o re?so de ?guas cinzas tem sido estudado como uma alternativa para usos n?o pot?veis. O objetivo deste trabalho foi avaliar o potencial de re?so de ?gua cinza tratada (ACT) em uma resid?ncia de alto padr?o em Feira de Santana ? BA. Analisou-se o risco microbiol?gico atrav?s da metodologia da Avalia??o Quantitativa de Risco Microbiol?gico (AQRM); o potencial de gera??o de maus odores por meio de pH, OD e ORP; a cor medida diretamente; e a energia incorporada usando a metodologia da An?lise do Ciclo de Vida (ACV). A m?dia do risco microbiol?gico da ACT foi da ordem de 10-5 DALY.pppa-1. A ACT tamb?m monstrou baixo potencial em gerar maus odores. A cor medida foi em m?dia 13,5 uH, com desvio padr?o de 10 uH. A intensidade energ?tica do sistema foi de 2,74 kWh/m? de ACT produzida, resultado inferior ao da concession?ria local. Conclui-se que a ?gua cinza (AC) possui grande potencial de re?so para fins menos nobres