Avalia??o da centraliza??o do preparo do canal radicular e da fadiga do instrumento comparando tr?s sistemas rotat?rios de n?quel-tit?nio

Made available in DSpace on 2015-04-14T13:30:13Z (GMT). No. of bitstreams: 1 438761.pdf: 1117817 bytes, checksum: 66a7869995a918890ef53d9067f6dc69 (MD5) Previous issue date: 2012-03-28 === Introduction: This in vitro study evaluated the capacity of centralization of the preparation, as well as the...

Full description

Bibliographic Details
Main Author: B?rgel, Mar?lia Ostermann
Other Authors: Pelisser, Fabiana Vieira Vier
Format: Others
Language:Portuguese
Published: Pontif?cia Universidade Cat?lica do Rio Grande do Sul 2015
Subjects:
Online Access:http://tede2.pucrs.br/tede2/handle/tede/1172
id ndltd-IBICT-oai-tede2.pucrs.br-tede-1172
record_format oai_dc
collection NDLTD
language Portuguese
format Others
sources NDLTD
topic ODONTOLOGIA
ENDODONTIA
CANAL RADICULAR
MICROSCOPIA ELETR?NICA
TOMOGRAFIA
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
spellingShingle ODONTOLOGIA
ENDODONTIA
CANAL RADICULAR
MICROSCOPIA ELETR?NICA
TOMOGRAFIA
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA
B?rgel, Mar?lia Ostermann
Avalia??o da centraliza??o do preparo do canal radicular e da fadiga do instrumento comparando tr?s sistemas rotat?rios de n?quel-tit?nio
description Made available in DSpace on 2015-04-14T13:30:13Z (GMT). No. of bitstreams: 1 438761.pdf: 1117817 bytes, checksum: 66a7869995a918890ef53d9067f6dc69 (MD5) Previous issue date: 2012-03-28 === Introduction: This in vitro study evaluated the capacity of centralization of the preparation, as well as the wear, distortion and fracture of three rotary nickel-titanium (Ni-Ti) systems Wizard CD Plus (WP), Wizard Navigator (WN) and BioRace(BR). Methodology: Were used 90 mesiobuccal roots (MV) of first upper molars (MS). The overlap of tomographic images before and after instrumentation was used to evaluate the transport of the preparation, at 2.0, 4.0, 6.0 and 8.0 mm from the apex. The instruments were observed by SEM before and after the third use, at its tip and at 5 mm of it. The data were analyzed by Kruskal-Wallis, complemented by Tukey test (P<0.05). Results: There was transport of the root canal in all groups, with no statistical difference between them (P> 0.05). There was no fracture and distortion at 5mm from the tip of the instruments. The group BR exhibited more distortion at the tip than the group WP (P = 0.011). There was more wear of the instrument in the group WP than in the BR (P <0.001). There was a progressive increase in distortion at the tip (P = 0.026) and of the wear (P <0.001) compared to the use in the group BR, as well as the wear in the group WP (P<0.001). Conclusion: None of the rotary systems employed was able to provide centralized preparation and the progressive use of the instruments did not favor the occurrence of fracture despite having increased the occurrence of distortion and wear === Introdu??o: Este estudo in vitro avaliou a capacidade de centraliza??o do preparo, bem como o desgaste distor??o e a fratura de tr?s tipos de instrumentos rotat?rios de n?quel-tit?nio (Ni-Ti) Wizard CD Plus (WP), Wizard Navigator (WN) e BioRace(BR). Metodologia: Foram utilizadas 90 ra?zes m?sio-vestibulares (MV) de primeiros molares superiores (1?s MS) e 10 conjuntos de cada tipo de instrumento rotat?rio. A sobreposi??o de imagens tomogr?ficas de feixe c?nico pr? e p?s-instrumenta??o avaliaram a capacidade de centraliza??o do preparo, a 2,0, 4,0, 6,0 e 8,0mm do ?pice. Os instrumentos foram avaliados em microscopia eletr?nica de varredura (MEV), antes e ap?s at? o terceiro uso, na sua ponta e a 5mm desta. Os dados foram analisados pelo Teste de Kruskal-Wallis, complementado pelo Teste de Tukey (P<0.05). Resultados: Houve transporte do canal radicular em todos os grupos, n?o havendo diferen?a estat?stica entre os mesmos (P>0.05). N?o houve fratura e distor??o a 5mm da ponta nos instrumentos analisados. O grupo BR apresentou mais distor??o na ponta do instrumento do que o grupo WP (P=0,011). Houve mais desgaste do instrumento no grupo WP do que no BR (P<0,001). Ocorreu aumento progressivo da distor??o na ponta do instrumento e do desgaste em rela??o ao uso no grupo BR (distor??o P=0,026 e desgaste P<0,001), assim como do desgaste no grupo WP (P<0,001). Conclus?o: Nenhum dos sistemas rotat?rios empregados foi capaz de proporcionar preparos centralizados e o uso progressivo dos instrumentos aumenta a ocorr?ncia de distor??o e desgastes em sua topografia.
author2 Pelisser, Fabiana Vieira Vier
author_facet Pelisser, Fabiana Vieira Vier
B?rgel, Mar?lia Ostermann
author B?rgel, Mar?lia Ostermann
author_sort B?rgel, Mar?lia Ostermann
title Avalia??o da centraliza??o do preparo do canal radicular e da fadiga do instrumento comparando tr?s sistemas rotat?rios de n?quel-tit?nio
title_short Avalia??o da centraliza??o do preparo do canal radicular e da fadiga do instrumento comparando tr?s sistemas rotat?rios de n?quel-tit?nio
title_full Avalia??o da centraliza??o do preparo do canal radicular e da fadiga do instrumento comparando tr?s sistemas rotat?rios de n?quel-tit?nio
title_fullStr Avalia??o da centraliza??o do preparo do canal radicular e da fadiga do instrumento comparando tr?s sistemas rotat?rios de n?quel-tit?nio
title_full_unstemmed Avalia??o da centraliza??o do preparo do canal radicular e da fadiga do instrumento comparando tr?s sistemas rotat?rios de n?quel-tit?nio
title_sort avalia??o da centraliza??o do preparo do canal radicular e da fadiga do instrumento comparando tr?s sistemas rotat?rios de n?quel-tit?nio
publisher Pontif?cia Universidade Cat?lica do Rio Grande do Sul
publishDate 2015
url http://tede2.pucrs.br/tede2/handle/tede/1172
work_keys_str_mv AT brgelmarliaostermann avaliaodacentralizaodopreparodocanalradicularedafadigadoinstrumentocomparandotrssistemasrotatriosdenqueltitnio
_version_ 1718950607407022080
spelling ndltd-IBICT-oai-tede2.pucrs.br-tede-11722019-01-22T02:26:10Z Avalia??o da centraliza??o do preparo do canal radicular e da fadiga do instrumento comparando tr?s sistemas rotat?rios de n?quel-tit?nio B?rgel, Mar?lia Ostermann Pelisser, Fabiana Vieira Vier ODONTOLOGIA ENDODONTIA CANAL RADICULAR MICROSCOPIA ELETR?NICA TOMOGRAFIA CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA Made available in DSpace on 2015-04-14T13:30:13Z (GMT). No. of bitstreams: 1 438761.pdf: 1117817 bytes, checksum: 66a7869995a918890ef53d9067f6dc69 (MD5) Previous issue date: 2012-03-28 Introduction: This in vitro study evaluated the capacity of centralization of the preparation, as well as the wear, distortion and fracture of three rotary nickel-titanium (Ni-Ti) systems Wizard CD Plus (WP), Wizard Navigator (WN) and BioRace(BR). Methodology: Were used 90 mesiobuccal roots (MV) of first upper molars (MS). The overlap of tomographic images before and after instrumentation was used to evaluate the transport of the preparation, at 2.0, 4.0, 6.0 and 8.0 mm from the apex. The instruments were observed by SEM before and after the third use, at its tip and at 5 mm of it. The data were analyzed by Kruskal-Wallis, complemented by Tukey test (P<0.05). Results: There was transport of the root canal in all groups, with no statistical difference between them (P> 0.05). There was no fracture and distortion at 5mm from the tip of the instruments. The group BR exhibited more distortion at the tip than the group WP (P = 0.011). There was more wear of the instrument in the group WP than in the BR (P <0.001). There was a progressive increase in distortion at the tip (P = 0.026) and of the wear (P <0.001) compared to the use in the group BR, as well as the wear in the group WP (P<0.001). Conclusion: None of the rotary systems employed was able to provide centralized preparation and the progressive use of the instruments did not favor the occurrence of fracture despite having increased the occurrence of distortion and wear Introdu??o: Este estudo in vitro avaliou a capacidade de centraliza??o do preparo, bem como o desgaste distor??o e a fratura de tr?s tipos de instrumentos rotat?rios de n?quel-tit?nio (Ni-Ti) Wizard CD Plus (WP), Wizard Navigator (WN) e BioRace(BR). Metodologia: Foram utilizadas 90 ra?zes m?sio-vestibulares (MV) de primeiros molares superiores (1?s MS) e 10 conjuntos de cada tipo de instrumento rotat?rio. A sobreposi??o de imagens tomogr?ficas de feixe c?nico pr? e p?s-instrumenta??o avaliaram a capacidade de centraliza??o do preparo, a 2,0, 4,0, 6,0 e 8,0mm do ?pice. Os instrumentos foram avaliados em microscopia eletr?nica de varredura (MEV), antes e ap?s at? o terceiro uso, na sua ponta e a 5mm desta. Os dados foram analisados pelo Teste de Kruskal-Wallis, complementado pelo Teste de Tukey (P<0.05). Resultados: Houve transporte do canal radicular em todos os grupos, n?o havendo diferen?a estat?stica entre os mesmos (P>0.05). N?o houve fratura e distor??o a 5mm da ponta nos instrumentos analisados. O grupo BR apresentou mais distor??o na ponta do instrumento do que o grupo WP (P=0,011). Houve mais desgaste do instrumento no grupo WP do que no BR (P<0,001). Ocorreu aumento progressivo da distor??o na ponta do instrumento e do desgaste em rela??o ao uso no grupo BR (distor??o P=0,026 e desgaste P<0,001), assim como do desgaste no grupo WP (P<0,001). Conclus?o: Nenhum dos sistemas rotat?rios empregados foi capaz de proporcionar preparos centralizados e o uso progressivo dos instrumentos aumenta a ocorr?ncia de distor??o e desgastes em sua topografia. 2015-04-14T13:30:13Z 2012-05-31 2012-03-28 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/masterThesis B?RGEL, Mar?lia Ostermann. Avalia??o da centraliza??o do preparo do canal radicular e da fadiga do instrumento comparando tr?s sistemas rotat?rios de n?quel-tit?nio. 2012. 53 f. Disserta??o (Mestrado em Odontologia) - Pontif?cia Universidade Cat?lica do Rio Grande do Sul, Porto Alegre, 2012. http://tede2.pucrs.br/tede2/handle/tede/1172 por -8096554818733665164 500 600 4673435736271820140 info:eu-repo/semantics/openAccess application/pdf Pontif?cia Universidade Cat?lica do Rio Grande do Sul Programa de P?s-Gradua??o em Odontologia PUCRS BR Faculdade de Odontologia reponame:Biblioteca Digital de Teses e Dissertações da PUC_RS instname:Pontifícia Universidade Católica do Rio Grande do Sul instacron:PUC_RS