ESTUDO COMPARATIVO DAS ANGULAÇÕES E TORQUES DE BRAQUETES DE DIFERENTES MARCAS COMERCIAIS

Made available in DSpace on 2016-08-03T16:31:12Z (GMT). No. of bitstreams: 1 Alexandre Zanesco.pdf: 1035848 bytes, checksum: d02024f61764f0328225b9a073241130 (MD5) Previous issue date: 2008-04-27 === The purpose of this study was to compare the angulations and torques of orthodontic brackets from...

Full description

Bibliographic Details
Main Author: Zanesco, Alexandre
Other Authors: Angelieri, Fernanda
Format: Others
Language:Portuguese
Published: Universidade Metodista de São Paulo 2016
Subjects:
Online Access:http://tede.metodista.br/jspui/handle/tede/1261
id ndltd-IBICT-oai-tahbit.umesp.edu.dti-tede-1261
record_format oai_dc
spelling ndltd-IBICT-oai-tahbit.umesp.edu.dti-tede-12612018-11-27T06:05:48Z ESTUDO COMPARATIVO DAS ANGULAÇÕES E TORQUES DE BRAQUETES DE DIFERENTES MARCAS COMERCIAIS Comparative study of angulation and inclination of different brackets trademarks Zanesco, Alexandre Angelieri, Fernanda Braquetes ortodônticos Torque (Ortodontia) Aparelhos ortodônticos CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::ORTODONTIA Made available in DSpace on 2016-08-03T16:31:12Z (GMT). No. of bitstreams: 1 Alexandre Zanesco.pdf: 1035848 bytes, checksum: d02024f61764f0328225b9a073241130 (MD5) Previous issue date: 2008-04-27 The purpose of this study was to compare the angulations and torques of orthodontic brackets from different trademarks in relation to the Roth s prescription and also in relation with the recommended values from the manufacturer. It was used 150 orthodontic metalic stainless steel brackets, from upper cuspid and incisors in its prescription and evaluated through a vertical Benchtop Measuring Projector in the Metrology laboratory of Dental Morelli Ltda. After collecting the results and the application of statistical test, it was obtained that values of torque found with the Roth´s prescription was similar between the manufacturer and the cuspid angulation has been shown higher values in comparison to that proposed from the author in the manufacturer Morelli, and for the teeth 2.1 and 2.2, the increased angulation was showed on Abzil manufacturer s bracket. On comparative values of torque obtained within all manufacturers, Unitek showed greater reliability in torque values than others. For angulation, the reliability of the same manufacture was not superious when compared to the other manufacturers. It was concluded that the differences on both torque and angulation to the author values and prescription of the manufacturers studies fall within the degree of advocated tolerance by a German association of orthodontic accessories. O objetivo deste estudo foi comparar as angulações e torques de braquetes de marcas comerciais distintas em relação à prescrição de Roth e também em relação aos valores preconizados pelo fabricante. Foram utilizados 150 braquetes metálicos de aço inoxidável, de caninos e incisivos superiores na respectiva prescrição, avaliadas por meio de um perfilômetro. Após a coleta dos dados e aplicação do tratamento estatístico, os resultados demonstraram que os valores de torque obtidos com a prescrição de Roth foram semelhantes entre os fabricantes. Na angulação, os caninos superiores apresentaram valores acima do proposto pelo autor para o fabricante Morelli, e para os dentes 21 e 22, a angulação foi maior para o fabricante Abzil. Na comparação dos valores de torque obtidos com os valores recomendados pelos fabricantes, a Unitek demonstrou maior fidedignidade no torque comparada às demais marcas. Conclui-se que as diferenças tanto de torque quanto de angulação quando comparados aos valores do autor e à prescrição dos fabricantes, se enquadram dentro de um grau de tolerância preconizada por um órgão regulador de peças ortodônticas alemãs. 2016-08-03T16:31:12Z 2008-09-24 2008-04-27 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/masterThesis ZANESCO, Alexandre. Comparative study of angulation and inclination of different brackets trademarks. 2008. 105 f. Dissertação (Mestrado em Ortodontia) - Universidade Metodista de São Paulo, São Bernardo do Campo, 2008. http://tede.metodista.br/jspui/handle/tede/1261 por info:eu-repo/semantics/openAccess application/pdf Universidade Metodista de São Paulo PÓS GRADUAÇÃO EM ORTODONTIA UMESP BR Ortodontia reponame:Biblioteca Digital de Teses e Dissertações da METODISTA instname:Universidade Metodista de São Paulo instacron:METODISTA
collection NDLTD
language Portuguese
format Others
sources NDLTD
topic Braquetes ortodônticos
Torque (Ortodontia)
Aparelhos ortodônticos
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::ORTODONTIA
spellingShingle Braquetes ortodônticos
Torque (Ortodontia)
Aparelhos ortodônticos
CNPQ::CIENCIAS DA SAUDE::ODONTOLOGIA::ORTODONTIA
Zanesco, Alexandre
ESTUDO COMPARATIVO DAS ANGULAÇÕES E TORQUES DE BRAQUETES DE DIFERENTES MARCAS COMERCIAIS
description Made available in DSpace on 2016-08-03T16:31:12Z (GMT). No. of bitstreams: 1 Alexandre Zanesco.pdf: 1035848 bytes, checksum: d02024f61764f0328225b9a073241130 (MD5) Previous issue date: 2008-04-27 === The purpose of this study was to compare the angulations and torques of orthodontic brackets from different trademarks in relation to the Roth s prescription and also in relation with the recommended values from the manufacturer. It was used 150 orthodontic metalic stainless steel brackets, from upper cuspid and incisors in its prescription and evaluated through a vertical Benchtop Measuring Projector in the Metrology laboratory of Dental Morelli Ltda. After collecting the results and the application of statistical test, it was obtained that values of torque found with the Roth´s prescription was similar between the manufacturer and the cuspid angulation has been shown higher values in comparison to that proposed from the author in the manufacturer Morelli, and for the teeth 2.1 and 2.2, the increased angulation was showed on Abzil manufacturer s bracket. On comparative values of torque obtained within all manufacturers, Unitek showed greater reliability in torque values than others. For angulation, the reliability of the same manufacture was not superious when compared to the other manufacturers. It was concluded that the differences on both torque and angulation to the author values and prescription of the manufacturers studies fall within the degree of advocated tolerance by a German association of orthodontic accessories. === O objetivo deste estudo foi comparar as angulações e torques de braquetes de marcas comerciais distintas em relação à prescrição de Roth e também em relação aos valores preconizados pelo fabricante. Foram utilizados 150 braquetes metálicos de aço inoxidável, de caninos e incisivos superiores na respectiva prescrição, avaliadas por meio de um perfilômetro. Após a coleta dos dados e aplicação do tratamento estatístico, os resultados demonstraram que os valores de torque obtidos com a prescrição de Roth foram semelhantes entre os fabricantes. Na angulação, os caninos superiores apresentaram valores acima do proposto pelo autor para o fabricante Morelli, e para os dentes 21 e 22, a angulação foi maior para o fabricante Abzil. Na comparação dos valores de torque obtidos com os valores recomendados pelos fabricantes, a Unitek demonstrou maior fidedignidade no torque comparada às demais marcas. Conclui-se que as diferenças tanto de torque quanto de angulação quando comparados aos valores do autor e à prescrição dos fabricantes, se enquadram dentro de um grau de tolerância preconizada por um órgão regulador de peças ortodônticas alemãs.
author2 Angelieri, Fernanda
author_facet Angelieri, Fernanda
Zanesco, Alexandre
author Zanesco, Alexandre
author_sort Zanesco, Alexandre
title ESTUDO COMPARATIVO DAS ANGULAÇÕES E TORQUES DE BRAQUETES DE DIFERENTES MARCAS COMERCIAIS
title_short ESTUDO COMPARATIVO DAS ANGULAÇÕES E TORQUES DE BRAQUETES DE DIFERENTES MARCAS COMERCIAIS
title_full ESTUDO COMPARATIVO DAS ANGULAÇÕES E TORQUES DE BRAQUETES DE DIFERENTES MARCAS COMERCIAIS
title_fullStr ESTUDO COMPARATIVO DAS ANGULAÇÕES E TORQUES DE BRAQUETES DE DIFERENTES MARCAS COMERCIAIS
title_full_unstemmed ESTUDO COMPARATIVO DAS ANGULAÇÕES E TORQUES DE BRAQUETES DE DIFERENTES MARCAS COMERCIAIS
title_sort estudo comparativo das angulações e torques de braquetes de diferentes marcas comerciais
publisher Universidade Metodista de São Paulo
publishDate 2016
url http://tede.metodista.br/jspui/handle/tede/1261
work_keys_str_mv AT zanescoalexandre estudocomparativodasangulacoesetorquesdebraquetesdediferentesmarcascomerciais
AT zanescoalexandre comparativestudyofangulationandinclinationofdifferentbracketstrademarks
_version_ 1718798700424200192