Análise bacteriológica da água utilizada nos equipos odontológicos do serviço público de Aracaju/SE
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior === Through bacteriological analyses, quality of water used in odontologic equipment of the Public Service in Aracaju was evaluated. 118 water samples were collected from 59 equipments and distributed in three groups according to the locali...
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Language: | Portuguese |
Published: |
Universidade Federal de Sergipe
2017
|
Subjects: | |
Online Access: | https://ri.ufs.br/handle/riufs/3835 |
id |
ndltd-IBICT-oai-ri.ufs.br-riufs-3835 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-IBICT-oai-ri.ufs.br-riufs-38352019-01-21T19:38:10Z Análise bacteriológica da água utilizada nos equipos odontológicos do serviço público de Aracaju/SE Paixão, Mônica Silveira Trindade, Rita de Cássia Equipamento odontológico Colimetria Controle de infecção Análise de água Dental equipments Colimetry Infection control Water analysis CNPQ::CIENCIAS DA SAUDE::MEDICINA Coordenação de Aperfeiçoamento de Pessoal de Nível Superior Through bacteriological analyses, quality of water used in odontologic equipment of the Public Service in Aracaju was evaluated. 118 water samples were collected from 59 equipments and distributed in three groups according to the localization of the reservoirs and the system availability of Flush Antisepsis. The present research was supposed to investigate the contamination with total and fecal coliforms in the water used in 24 equipments of Odontology Department and 35 equipments of Health Basic Units, which corresponds to 50% of total odontologic equipment in functioning in the Federal and Municipal Public Service. Also, the relation between quality of water and mark of Odontologic Equipment/Time of working of the same ones was analyzed. The samples were analyzed in Applied Microbiology Laboratory in the Federal University of Sergipe, from April 2005 to March 2006, using the Multiple Pipes Technique. Among 118 analyzed samples, 03 (three) them were unsuitable for human consumption and, consequently, for odontologic use, according to the current law in Brazil. The bactericidal effects of the Flush system were not observed, independent of the mark and time of the equipment functioning. Através de análises bacteriológicas, avaliou-se a qualidade da água utilizada nos Equipos Odontológicos do Serviço Público de Aracaju. Foram coletadas 118 amostras de água procedentes de 59 Equipos distribuídos em três grupos, de acordo com a localização dos reservatórios e a disponibilidade do sistema de anti-sepsia Flush. A presente pesquisa se propôs a investigar a contaminação por coliformes totais e fecais na água utilizada em 24 Equipos do Departamento de Odontologia e 35 Equipos das Unidades Básicas de Saúde, o que corresponde a 50% do total de Equipamentos Odontológicos em funcionamento no Serviço Público Federal e Municipal, respectivamente. Também foi analisada a relação entre qualidade da água e Marca dos Equipamentos Odontológicos/Tempo de Funcionamento dos mesmos. As amostras foram analisadas no Laboratório de Microbiologia Aplicada da Universidade Federal de Sergipe/UFS, no período de abril/2005 a março/2006, utilizando-se a Técnica de Tubos Múltiplos. Das 118 amostras analisadas 03 (três) apresentaram-se impróprias para consumo humano e, conseqüentemente, impróprias para uso odontológico, de acordo com a legislação vigente no Brasil. Não foram observados os supostos efeitos bactericidas do sistema Flush, independente da marca e tempo de funcionamento dos equipamentos. 2017-09-26T12:17:53Z 2017-09-26T12:17:53Z 2006-09-28 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/masterThesis PAIXÃO, Mônica Silveira. ANÁLISE BACTERIOLÓGICA DA ÁGUA UTILIZADA NOS EQUIPOS ODONTOLÓGICOS DO SERVIÇO PÚBLICO DE ARACAJU/SE. 2006. 80 f. Dissertação (Mestrado em Ciências da Saúde) - Universidade Federal de Sergipe, Aracaju, 2006. https://ri.ufs.br/handle/riufs/3835 por info:eu-repo/semantics/openAccess application/pdf Universidade Federal de Sergipe Pós-Graduação em Ciências da Saúde UFS BR reponame:Repositório Institucional da UFS instname:Universidade Federal de Sergipe instacron:UFS |
collection |
NDLTD |
language |
Portuguese |
format |
Others
|
sources |
NDLTD |
topic |
Equipamento odontológico Colimetria Controle de infecção Análise de água Dental equipments Colimetry Infection control Water analysis CNPQ::CIENCIAS DA SAUDE::MEDICINA |
spellingShingle |
Equipamento odontológico Colimetria Controle de infecção Análise de água Dental equipments Colimetry Infection control Water analysis CNPQ::CIENCIAS DA SAUDE::MEDICINA Paixão, Mônica Silveira Análise bacteriológica da água utilizada nos equipos odontológicos do serviço público de Aracaju/SE |
description |
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior === Through bacteriological analyses, quality of water used in odontologic equipment of the Public Service in Aracaju was evaluated. 118 water samples were collected from 59 equipments and distributed in three groups according to the localization of the reservoirs and the system availability of Flush Antisepsis. The present research was supposed to investigate the contamination with total and fecal coliforms in the water used in 24 equipments of Odontology Department and 35 equipments of Health Basic Units, which corresponds to 50% of total odontologic equipment in functioning in the Federal and Municipal Public Service. Also, the relation between quality of water and mark of Odontologic Equipment/Time of working of the same ones was analyzed. The samples were analyzed in Applied Microbiology Laboratory
in the Federal University of Sergipe, from April 2005 to March 2006, using the Multiple Pipes Technique. Among 118 analyzed samples, 03 (three) them were unsuitable for human consumption and, consequently, for odontologic use, according to the current law in Brazil. The bactericidal effects of the Flush system were not observed, independent of the mark and time of the equipment functioning. === Através de análises bacteriológicas, avaliou-se a qualidade da água utilizada nos Equipos Odontológicos do Serviço Público de Aracaju. Foram coletadas 118 amostras de água procedentes de 59 Equipos distribuídos em três grupos, de acordo com a localização dos reservatórios e a disponibilidade do sistema de anti-sepsia Flush. A presente pesquisa se propôs a investigar a contaminação por coliformes totais e fecais na água utilizada em 24 Equipos do Departamento de Odontologia e 35 Equipos das Unidades Básicas de Saúde, o que corresponde a 50% do total de Equipamentos Odontológicos em funcionamento no Serviço Público Federal e
Municipal, respectivamente. Também foi analisada a relação entre qualidade da água e Marca dos Equipamentos Odontológicos/Tempo de Funcionamento dos mesmos.
As amostras foram analisadas no Laboratório de Microbiologia Aplicada da Universidade Federal de Sergipe/UFS, no período de abril/2005 a março/2006, utilizando-se a Técnica de Tubos Múltiplos. Das 118 amostras analisadas 03 (três) apresentaram-se impróprias para consumo humano e, conseqüentemente, impróprias para uso odontológico, de acordo com a legislação vigente no Brasil. Não foram
observados os supostos efeitos bactericidas do sistema Flush, independente da marca e tempo de funcionamento dos equipamentos. |
author2 |
Trindade, Rita de Cássia |
author_facet |
Trindade, Rita de Cássia Paixão, Mônica Silveira |
author |
Paixão, Mônica Silveira |
author_sort |
Paixão, Mônica Silveira |
title |
Análise bacteriológica da água utilizada nos equipos odontológicos do serviço público de Aracaju/SE |
title_short |
Análise bacteriológica da água utilizada nos equipos odontológicos do serviço público de Aracaju/SE |
title_full |
Análise bacteriológica da água utilizada nos equipos odontológicos do serviço público de Aracaju/SE |
title_fullStr |
Análise bacteriológica da água utilizada nos equipos odontológicos do serviço público de Aracaju/SE |
title_full_unstemmed |
Análise bacteriológica da água utilizada nos equipos odontológicos do serviço público de Aracaju/SE |
title_sort |
análise bacteriológica da água utilizada nos equipos odontológicos do serviço público de aracaju/se |
publisher |
Universidade Federal de Sergipe |
publishDate |
2017 |
url |
https://ri.ufs.br/handle/riufs/3835 |
work_keys_str_mv |
AT paixaomonicasilveira analisebacteriologicadaaguautilizadanosequiposodontologicosdoservicopublicodearacajuse |
_version_ |
1718867226972389376 |