ENSAIOS DE PLACAS EM SOLO LATERÍTICO NA CIDADE DE SANTO ÂNGELO
This thesis presents a study of the behavior of a soil profile typical of the Santo Ângelo city, the board is tested. This study aimed to investigate the behavior of natural soil, waterlogged, compacted and with addition of cement for their application in shallow foundations. The load tests were con...
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Language: | Portuguese |
Published: |
Universidade Federal de Santa Maria
2011
|
Subjects: | |
Online Access: | http://repositorio.ufsm.br/handle/1/7758 |
id |
ndltd-IBICT-oai-repositorio.ufsm.br-1-7758 |
---|---|
record_format |
oai_dc |
collection |
NDLTD |
language |
Portuguese |
format |
Others
|
sources |
NDLTD |
topic |
Solo laterítico Ensaio de placas Geotécnica Soil lateritic Assay plates Geotechnical CNPQ::ENGENHARIAS::ENGENHARIA CIVIL |
spellingShingle |
Solo laterítico Ensaio de placas Geotécnica Soil lateritic Assay plates Geotechnical CNPQ::ENGENHARIAS::ENGENHARIA CIVIL Kublik, Cristiane ENSAIOS DE PLACAS EM SOLO LATERÍTICO NA CIDADE DE SANTO ÂNGELO |
description |
This thesis presents a study of the behavior of a soil profile typical of the Santo Ângelo city, the board is tested. This study aimed to investigate the behavior of natural soil, waterlogged, compacted and with addition of cement for their application in shallow foundations. The load tests were conducted in an area next to the building of the laboratories of the Civil Engineering Course, at Universidade Regional Integrada do Alto Uruguai e das Missões , URI, in Santo Ângelo. The geotechnical characterization tests were conducted in disturbed
and undisturbed samples collected from trenches and pits during the test plate. Pedologicaly soil consists of a thick surface horizon (horizon A and B) classified as Typic. This texturally soils were classified as silty clays and silty clays, sandy, porous and unsaturated. In terms of resistance of these soils show a cohesion of 10 kPa and a friction angle of 32 degrees. These values are reduced as flooded, mainly in relation to cohesion. The flooding also reduces the strength parameters, causes a collapse that was assessed by means of direct shear tests and compression tests contained doubles. The collapse of values measured was between 1% and 3%. The effect of flooding there was also confined compression tests, with the stress reduction of pre-densification and increased compressibility. In plate tests verified the influence of flooding on the deformability and strength of these soils. Flooding increased deformability and reduced the resistance, but it was found that a natural rain prior to testing in natural soil was more effective than a process of artificial flooding. For tests on compacted soil and soil-cement had decreased deformability and increased resistance of these soils. This increased rigidity and resistance was more intense in the soil-cement. Therefore, the use of compression techniques and the addition of cement increases the load capacity of soils for use
in shallow foundations. === Esta dissertação apresenta um estudo do comportamento de um perfil de solo típico da cidade de Santo Ângelo, submetido a ensaios de placa, cujo principal objetivo é verificar o
comportamento do solo natural, inundado, compactado e com adição de cimento visando a sua aplicação em fundações superficiais. As provas de carga foram realizadas numa área ao
lado do prédio dos laboratórios do Curso de Engenharia Civil da Universidade Regional Integrada do Alto Uruguai das Missões (URI), na cidade de Santo Ângelo. Os ensaios de
caracterização e geotécnicos foram realizados em amostradas deformadas e indeformadas, coletadas em trincheira e cavas durante os ensaios de placa. Pedologicamente o solo é
constituído por um espesso horizonte superficial (horizonte A e B), classificado como Latossolo. Texturalmente esse solos foram classificados como argilas siltosas e argilas siltoarenosas, porosas e não saturadas. Em termos de resistência, eles apresentam uma coesão de 10 kPa e um ângulo de atrito de 32º. Esses valores são reduzidos tanto quanto inundados, principalmente em relação à coesão. A inundação, além de reduzir os parâmetros de resistência, ocasiona um colapso que foi avaliado por meio dos ensaios de cisalhamento direto e ensaios de compressão confinada duplos. Os valores de colapso medidos situaram-se entre
1% e 3%. O efeito da inundação verificou-se também nos ensaios de compressão confinada, com a redução da tensão de pré-adensamento e o aumento da compressibilidade. Nos ensaios de placa, verificou-se a influência da inundação na deformabilidade e resistência desses solos. A inundação aumentou a deformabilidade e diminuiu a resistência, mas verificou-se que uma chuva natural, anterior ao ensaio, no solo natural, foi muito mais efetiva que um processo de
inundação artificial. Nos ensaios realizados no solo compactado e solo-cimento, ocorreu uma diminuição da deformabilidade e aumento da resistência desses solos. Esse aumento de rigidez e resistência foi mais intenso no solo-cimento. Portanto, a utilização de técnicas de compactação e adição de cimento aumenta a capacidade de carga de solos para utilização em fundações superficiais. |
author2 |
Pinheiro, Rinaldo Jose Barbosa |
author_facet |
Pinheiro, Rinaldo Jose Barbosa Kublik, Cristiane |
author |
Kublik, Cristiane |
author_sort |
Kublik, Cristiane |
title |
ENSAIOS DE PLACAS EM SOLO LATERÍTICO NA CIDADE DE SANTO ÂNGELO |
title_short |
ENSAIOS DE PLACAS EM SOLO LATERÍTICO NA CIDADE DE SANTO ÂNGELO |
title_full |
ENSAIOS DE PLACAS EM SOLO LATERÍTICO NA CIDADE DE SANTO ÂNGELO |
title_fullStr |
ENSAIOS DE PLACAS EM SOLO LATERÍTICO NA CIDADE DE SANTO ÂNGELO |
title_full_unstemmed |
ENSAIOS DE PLACAS EM SOLO LATERÍTICO NA CIDADE DE SANTO ÂNGELO |
title_sort |
ensaios de placas em solo laterítico na cidade de santo ângelo |
publisher |
Universidade Federal de Santa Maria |
publishDate |
2011 |
url |
http://repositorio.ufsm.br/handle/1/7758 |
work_keys_str_mv |
AT kublikcristiane ensaiosdeplacasemsololateriticonacidadedesantoangelo AT kublikcristiane testonplatesinsoillateriticcityofsantoangelo |
_version_ |
1718642397135503360 |
spelling |
ndltd-IBICT-oai-repositorio.ufsm.br-1-77582018-05-23T17:05:13Z ENSAIOS DE PLACAS EM SOLO LATERÍTICO NA CIDADE DE SANTO ÂNGELO TEST ON PLATES IN SOIL LATERITIC CITY OF SANTO ÂNGELO Kublik, Cristiane Pinheiro, Rinaldo Jose Barbosa Soares, José Mario Doleys Pereira, Deividi da Silva Vendruscolo, Márcio Antônio Solo laterítico Ensaio de placas Geotécnica Soil lateritic Assay plates Geotechnical CNPQ::ENGENHARIAS::ENGENHARIA CIVIL This thesis presents a study of the behavior of a soil profile typical of the Santo Ângelo city, the board is tested. This study aimed to investigate the behavior of natural soil, waterlogged, compacted and with addition of cement for their application in shallow foundations. The load tests were conducted in an area next to the building of the laboratories of the Civil Engineering Course, at Universidade Regional Integrada do Alto Uruguai e das Missões , URI, in Santo Ângelo. The geotechnical characterization tests were conducted in disturbed and undisturbed samples collected from trenches and pits during the test plate. Pedologicaly soil consists of a thick surface horizon (horizon A and B) classified as Typic. This texturally soils were classified as silty clays and silty clays, sandy, porous and unsaturated. In terms of resistance of these soils show a cohesion of 10 kPa and a friction angle of 32 degrees. These values are reduced as flooded, mainly in relation to cohesion. The flooding also reduces the strength parameters, causes a collapse that was assessed by means of direct shear tests and compression tests contained doubles. The collapse of values measured was between 1% and 3%. The effect of flooding there was also confined compression tests, with the stress reduction of pre-densification and increased compressibility. In plate tests verified the influence of flooding on the deformability and strength of these soils. Flooding increased deformability and reduced the resistance, but it was found that a natural rain prior to testing in natural soil was more effective than a process of artificial flooding. For tests on compacted soil and soil-cement had decreased deformability and increased resistance of these soils. This increased rigidity and resistance was more intense in the soil-cement. Therefore, the use of compression techniques and the addition of cement increases the load capacity of soils for use in shallow foundations. Esta dissertação apresenta um estudo do comportamento de um perfil de solo típico da cidade de Santo Ângelo, submetido a ensaios de placa, cujo principal objetivo é verificar o comportamento do solo natural, inundado, compactado e com adição de cimento visando a sua aplicação em fundações superficiais. As provas de carga foram realizadas numa área ao lado do prédio dos laboratórios do Curso de Engenharia Civil da Universidade Regional Integrada do Alto Uruguai das Missões (URI), na cidade de Santo Ângelo. Os ensaios de caracterização e geotécnicos foram realizados em amostradas deformadas e indeformadas, coletadas em trincheira e cavas durante os ensaios de placa. Pedologicamente o solo é constituído por um espesso horizonte superficial (horizonte A e B), classificado como Latossolo. Texturalmente esse solos foram classificados como argilas siltosas e argilas siltoarenosas, porosas e não saturadas. Em termos de resistência, eles apresentam uma coesão de 10 kPa e um ângulo de atrito de 32º. Esses valores são reduzidos tanto quanto inundados, principalmente em relação à coesão. A inundação, além de reduzir os parâmetros de resistência, ocasiona um colapso que foi avaliado por meio dos ensaios de cisalhamento direto e ensaios de compressão confinada duplos. Os valores de colapso medidos situaram-se entre 1% e 3%. O efeito da inundação verificou-se também nos ensaios de compressão confinada, com a redução da tensão de pré-adensamento e o aumento da compressibilidade. Nos ensaios de placa, verificou-se a influência da inundação na deformabilidade e resistência desses solos. A inundação aumentou a deformabilidade e diminuiu a resistência, mas verificou-se que uma chuva natural, anterior ao ensaio, no solo natural, foi muito mais efetiva que um processo de inundação artificial. Nos ensaios realizados no solo compactado e solo-cimento, ocorreu uma diminuição da deformabilidade e aumento da resistência desses solos. Esse aumento de rigidez e resistência foi mais intenso no solo-cimento. Portanto, a utilização de técnicas de compactação e adição de cimento aumenta a capacidade de carga de solos para utilização em fundações superficiais. 2011-04-04 2011-04-04 2010-12-21 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/masterThesis KUBLIK, Cristiane. TEST ON PLATES IN SOIL LATERITIC CITY OF SANTO ÂNGELO. 2010. 100 f. Dissertação (Mestrado em Engenharia Civil) - Universidade Federal de Santa Maria, Santa Maria, 2010. http://repositorio.ufsm.br/handle/1/7758 por 300100000003 400 500 300 500 300 300 ae18a12f-8c35-44bc-9844-01d5dc7b8c91 a0cdd009-a117-45cc-b005-e9463be8d019 c529b05d-5474-4b4c-8d4a-3207d6f8c207 d96ee26c-775a-45bd-8b59-eeee070e8af5 c798b7a1-94ef-4a75-a070-c9ebd68f62cd info:eu-repo/semantics/openAccess application/pdf Universidade Federal de Santa Maria Programa de Pós-Graduação em Engenharia Civil UFSM BR Engenharia Civil reponame:Repositório Institucional da UFSM instname:Universidade Federal de Santa Maria instacron:UFSM |