Controle Adaptativo Robusto para Filtros Ativos de Pot?ncia Paralelo

Made available in DSpace on 2014-12-17T14:55:00Z (GMT). No. of bitstreams: 1 ChristianCA_TESE_1-77.pdf: 2508410 bytes, checksum: e0b647bf37424cb7dc8eeedc2d13d922 (MD5) Previous issue date: 2011-11-04 === Conventional control strategies used in shunt active power filters (SAPF) employs real-time...

Full description

Bibliographic Details
Main Author: Azevedo, Christian Cesar de
Other Authors: CPF:31804683434
Format: Others
Language:Portuguese
Published: Universidade Federal do Rio Grande do Norte 2014
Subjects:
Online Access:http://repositorio.ufrn.br:8080/jspui/handle/123456789/15160
id ndltd-IBICT-oai-repositorio.ufrn.br-123456789-15160
record_format oai_dc
collection NDLTD
language Portuguese
format Others
sources NDLTD
topic Filtros ativos
Controle adaptativo
Compensa??o de harm?nicos
Active filters
Adaptative control
Harmonic compensation
CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA
spellingShingle Filtros ativos
Controle adaptativo
Compensa??o de harm?nicos
Active filters
Adaptative control
Harmonic compensation
CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA
Azevedo, Christian Cesar de
Controle Adaptativo Robusto para Filtros Ativos de Pot?ncia Paralelo
description Made available in DSpace on 2014-12-17T14:55:00Z (GMT). No. of bitstreams: 1 ChristianCA_TESE_1-77.pdf: 2508410 bytes, checksum: e0b647bf37424cb7dc8eeedc2d13d922 (MD5) Previous issue date: 2011-11-04 === Conventional control strategies used in shunt active power filters (SAPF) employs real-time instantaneous harmonic detection schemes which is usually implements with digital filters. This increase the number of current sensors on the filter structure which results in high costs. Furthermore, these detection schemes introduce time delays which can deteriorate the harmonic compensation performance. Differently from the conventional control schemes, this paper proposes a non-standard control strategy which indirectly regulates the phase currents of the power mains. The reference currents of system are generated by the dc-link voltage controller and is based on the active power balance of SAPF system. The reference currents are aligned to the phase angle of the power mains voltage vector which is obtained by using a dq phase locked loop (PLL) system. The current control strategy is implemented by an adaptive pole placement control strategy integrated to a variable structure control scheme (VS-APPC). In the VS-APPC, the internal model principle (IMP) of reference currents is used for achieving the zero steady state tracking error of the power system currents. This forces the phase current of the system mains to be sinusoidal with low harmonics content. Moreover, the current controllers are implemented on the stationary reference frame to avoid transformations to the mains voltage vector reference coordinates. This proposed current control strategy enhance the performance of SAPF with fast transient response and robustness to parametric uncertainties. Experimental results are showing for determining the effectiveness of SAPF proposed control system === As estrat?gias de controle convencionais de filtros ativos de pot?ncia paralelos (SAPF - Shunt Active Power Filters) empregam esquemas de detec??o de harm?nicos em tempo real, usualmente implementados com filtros digitais. Isso pode resultar em altos custos devido o aumento no n?mero de sensores na estrutura do filtro. Al?m disso, esses esquemas de detec??o introduzem atrasos que podem deteriorar o desempenho da compensa??o de harm?nicos. Diferentemente dos esquemas de controle convencionais, este trabalho prop?e uma nova estrat?gia de controle que regula indiretamente as correntes de fase da rede el?trica. As correntes de refer?ncia do sistema s?o geradas pelo controle de tens?o do barramento CC e s?o baseadas no balan?o de pot?ncia ativa do sistema SAPF. As correntes de refer?ncia s?o alinhadas com o ?ngulo de fase do vetor tens?o da rede, que ? obtido usando um PLL (Phase Locked Loop). O controle de corrente ? implementado por uma estrat?gia de controle adaptativo por aloca??o de p?los, integrada com um esquema de controle com estrutura vari?vel (VS-APPC: Variable Structure - Adaptive Pole Placement Control). No VS-APPC, o princ?pio do modelo interno (IMP - Internal Model Principle) de refer?ncia ? usado para eliminar o erro em regime permanente das correntes de fase do sistema. Isso for?a as correntes de fase do sistema a serem senoidais e com baixo teor de harm?nicos. Al?m disso, os controladores de corrente s?o implementados no referencial estacion?rio para evitar transforma??es nas coordenadas de refer?ncia do vetor tens?o da rede. Esta estrat?gia de controle de corrente melhora a performance do SAPF com uma resposta transit?ria r?pida e robusto a incertezas param?tricas. Resultados experimentais s?o apresentados para demonstrar a efic?cia do sistema de controle proposto para o SAPF
author2 CPF:31804683434
author_facet CPF:31804683434
Azevedo, Christian Cesar de
author Azevedo, Christian Cesar de
author_sort Azevedo, Christian Cesar de
title Controle Adaptativo Robusto para Filtros Ativos de Pot?ncia Paralelo
title_short Controle Adaptativo Robusto para Filtros Ativos de Pot?ncia Paralelo
title_full Controle Adaptativo Robusto para Filtros Ativos de Pot?ncia Paralelo
title_fullStr Controle Adaptativo Robusto para Filtros Ativos de Pot?ncia Paralelo
title_full_unstemmed Controle Adaptativo Robusto para Filtros Ativos de Pot?ncia Paralelo
title_sort controle adaptativo robusto para filtros ativos de pot?ncia paralelo
publisher Universidade Federal do Rio Grande do Norte
publishDate 2014
url http://repositorio.ufrn.br:8080/jspui/handle/123456789/15160
work_keys_str_mv AT azevedochristiancesarde controleadaptativorobustoparafiltrosativosdepotnciaparalelo
_version_ 1718670560195510272
spelling ndltd-IBICT-oai-repositorio.ufrn.br-123456789-151602018-05-23T23:21:05Z Controle Adaptativo Robusto para Filtros Ativos de Pot?ncia Paralelo Azevedo, Christian Cesar de CPF:31804683434 http://lattes.cnpq.br/6628177274865696 Salazar, Andr?s Ortiz CPF:51618362968 http://lattes.cnpq.br/7865065553087432 Jacobina, Cursino Brand?o CPF:20523408404 http://lattes.cnpq.br/0261885352003041 Ribeiro, Ricardo L?cio de Ara?jo Filtros ativos Controle adaptativo Compensa??o de harm?nicos Active filters Adaptative control Harmonic compensation CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA Made available in DSpace on 2014-12-17T14:55:00Z (GMT). No. of bitstreams: 1 ChristianCA_TESE_1-77.pdf: 2508410 bytes, checksum: e0b647bf37424cb7dc8eeedc2d13d922 (MD5) Previous issue date: 2011-11-04 Conventional control strategies used in shunt active power filters (SAPF) employs real-time instantaneous harmonic detection schemes which is usually implements with digital filters. This increase the number of current sensors on the filter structure which results in high costs. Furthermore, these detection schemes introduce time delays which can deteriorate the harmonic compensation performance. Differently from the conventional control schemes, this paper proposes a non-standard control strategy which indirectly regulates the phase currents of the power mains. The reference currents of system are generated by the dc-link voltage controller and is based on the active power balance of SAPF system. The reference currents are aligned to the phase angle of the power mains voltage vector which is obtained by using a dq phase locked loop (PLL) system. The current control strategy is implemented by an adaptive pole placement control strategy integrated to a variable structure control scheme (VS-APPC). In the VS-APPC, the internal model principle (IMP) of reference currents is used for achieving the zero steady state tracking error of the power system currents. This forces the phase current of the system mains to be sinusoidal with low harmonics content. Moreover, the current controllers are implemented on the stationary reference frame to avoid transformations to the mains voltage vector reference coordinates. This proposed current control strategy enhance the performance of SAPF with fast transient response and robustness to parametric uncertainties. Experimental results are showing for determining the effectiveness of SAPF proposed control system As estrat?gias de controle convencionais de filtros ativos de pot?ncia paralelos (SAPF - Shunt Active Power Filters) empregam esquemas de detec??o de harm?nicos em tempo real, usualmente implementados com filtros digitais. Isso pode resultar em altos custos devido o aumento no n?mero de sensores na estrutura do filtro. Al?m disso, esses esquemas de detec??o introduzem atrasos que podem deteriorar o desempenho da compensa??o de harm?nicos. Diferentemente dos esquemas de controle convencionais, este trabalho prop?e uma nova estrat?gia de controle que regula indiretamente as correntes de fase da rede el?trica. As correntes de refer?ncia do sistema s?o geradas pelo controle de tens?o do barramento CC e s?o baseadas no balan?o de pot?ncia ativa do sistema SAPF. As correntes de refer?ncia s?o alinhadas com o ?ngulo de fase do vetor tens?o da rede, que ? obtido usando um PLL (Phase Locked Loop). O controle de corrente ? implementado por uma estrat?gia de controle adaptativo por aloca??o de p?los, integrada com um esquema de controle com estrutura vari?vel (VS-APPC: Variable Structure - Adaptive Pole Placement Control). No VS-APPC, o princ?pio do modelo interno (IMP - Internal Model Principle) de refer?ncia ? usado para eliminar o erro em regime permanente das correntes de fase do sistema. Isso for?a as correntes de fase do sistema a serem senoidais e com baixo teor de harm?nicos. Al?m disso, os controladores de corrente s?o implementados no referencial estacion?rio para evitar transforma??es nas coordenadas de refer?ncia do vetor tens?o da rede. Esta estrat?gia de controle de corrente melhora a performance do SAPF com uma resposta transit?ria r?pida e robusto a incertezas param?tricas. Resultados experimentais s?o apresentados para demonstrar a efic?cia do sistema de controle proposto para o SAPF 2014-12-17T14:55:00Z 2012-07-20 2014-12-17T14:55:00Z 2011-11-04 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/doctoralThesis AZEVEDO, Christian Cesar de. Controle Adaptativo Robusto para Filtros Ativos de Pot?ncia Paralelo. 2011. 235 f. Tese (Doutorado em Automa??o e Sistemas; Engenharia de Computa??o; Telecomunica??es) - Universidade Federal do Rio Grande do Norte, Natal, 2011. http://repositorio.ufrn.br:8080/jspui/handle/123456789/15160 por info:eu-repo/semantics/openAccess application/pdf Universidade Federal do Rio Grande do Norte Programa de P?s-Gradua??o em Engenharia El?trica UFRN BR Automa??o e Sistemas; Engenharia de Computa??o; Telecomunica??es reponame:Repositório Institucional da UFRN instname:Universidade Federal do Rio Grande do Norte instacron:UFRN