Monte Carlo modeling of the patient and treatment delivery complexities for high dose rate brachytherapy

Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-12-10T16:54:22Z No. of bitstreams: 0 === Made available in DSpace on 2015-12-10T16:54:22Z (GMT). No. of bitstreams: 0 === Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) === Tratamentos braquiterápicos são comumente realizad...

Full description

Bibliographic Details
Main Author: FONSECA, GABRIEL P.
Other Authors: Helio Yoriyaz
Format: Others
Published: 2015
Subjects:
Online Access:http://repositorio.ipen.br:8080/xmlui/handle/123456789/25298
id ndltd-IBICT-oai-repositorio.ipen.br-123456789-25298
record_format oai_dc
collection NDLTD
format Others
sources NDLTD
topic brachytherapy
iridium 192
absorbed radiation doses
monte carlo method
algorithms
calculation methods
computer codes
spellingShingle brachytherapy
iridium 192
absorbed radiation doses
monte carlo method
algorithms
calculation methods
computer codes
FONSECA, GABRIEL P.
Monte Carlo modeling of the patient and treatment delivery complexities for high dose rate brachytherapy
description Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-12-10T16:54:22Z No. of bitstreams: 0 === Made available in DSpace on 2015-12-10T16:54:22Z (GMT). No. of bitstreams: 0 === Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) === Tratamentos braquiterápicos são comumente realizados conforme o relatório da American Association of Physicists in Medicine (AAPM), Task Group report TG-43U1, o qual define o formalismo para cálculo de dose absorvida na água e não considera a composição dos materiais, densidades, dimensões do paciente e o efeito dos aplicadores. Estes efeitos podem ser significantes, conforme descrito pelo recente relatório da AAPM, Task Group report TG- 186, que define diretrizes para que sistemas de planejamento modernos, capazes de considerar as complexidades descritas acima, sejam implementados. Esta tese tem como objetivo contribuir para o aumento da exatidão dos planejamentos de tratamento braquiterápicos, seguindo as recomendações do TG-186 e indo além do mesmo. Um software foi desenvolvido para integrar planejamentos de tratamento e simulações pelo método de Monte Carlo (MC); modelos acurados, CAD-Mesh, foram utilizados para representar aplicadores braquiterápicos; Grandezas utilizadas para reportar dose absorvida, Dw,m (dose para água no meio) e Dm,m (dose para o meio no meio), foram calculadas para um tratamento de cabeça e pescoço, considerando a teoria para pequenas (SCT small cavity theory) e grandes cavidades (LCT large cavity theory); a componente da dose em razão do movimento da fonte foi avaliada para tratamentos de próstata e ginecológicos. Perfis de velocidade obtidos na literatura foram utilizados; medidas de velocidade de uma fonte braquiterapica foram realizadas com uma câmera de alta taxa de aquisição. Cálculos de dose obtidos usando MC (incluindo a composição e densidade dos tecidos, ar e o aplicador) mostram sobredoses de aproximadamente 5% dentro do volume alvo, em um tratamento ginecológico, quando comparados aos resultados obtidos com um meio homogêneo de água. Por sua vez, subdoses de aproximadamente 5% foram observadas ao considerar a composição dos tecidos e regiões com ar em um tratamento intersticial de braço. Um aplicador cilíndrico oco resultou na sobredose observada no caso ginecológico, ressaltando a necessidade de modelos acurados para representar os aplicadores. Os modelos CAD-Mesh utilizados incluem um aplicador Fletcher-Williamson, com blindagem, e um balão deformável para irradiação de mama. Os resultados obtidos com estes modelos são equivalentes aos obtidos com modelos geométricos convencionais. Este recurso pode ser conveniente para aplicadores complexos e/ou quando o projeto dos aplicadores for disponibilizado pelo fabricante. Cálculos de dose, com a composição real dos tecidos humanos, podem apresentar diferenças significativas em razão da grandeza adotada. Diferenças entre Dm,m e Dw,m (SCT ou LCT) chegam a 14% em razão da composição do osso. A metodologia adotada (SCT ou LCT) resulta em diferenças de até 28% para o osso e 36% para os dentes. A componente de dose de trânsito também pode levar a diferenças significativas, uma vez que baixas velocidades ou movimentos uniformemente acelerados foram descritos na literatura. Considerando a pior condição e sem incluir nenhuma correção no tempo de parada, a dose de trânsito pode chegar a 3% da dose prescrita para um caso ginecológico, com 4 cateteres, e até 11.1% da dose prescrita para um tratamento de próstata, com 16 cateteres. A dose de trânsito para a fonte avaliada (velocidade obtida experimentalmente) não é uniformemente distribuída e pode levar a sub ou sobredoses de até 1.4% das doses comumente prescritas (310 Gy). Os tópicos estudados são relevantes para tratamentos braquiterápicos e podem contribuir para o aumento de sua acurácia. Os efeitos estudados podem ser avaliados com o uso do software, associado a um código MC, desenvolvido. === Tese (Doutorado em Tecnologia Nuclear) === IPEN/T === Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP === FAPESP:11/01913-4
author2 Helio Yoriyaz
author_facet Helio Yoriyaz
FONSECA, GABRIEL P.
author FONSECA, GABRIEL P.
author_sort FONSECA, GABRIEL P.
title Monte Carlo modeling of the patient and treatment delivery complexities for high dose rate brachytherapy
title_short Monte Carlo modeling of the patient and treatment delivery complexities for high dose rate brachytherapy
title_full Monte Carlo modeling of the patient and treatment delivery complexities for high dose rate brachytherapy
title_fullStr Monte Carlo modeling of the patient and treatment delivery complexities for high dose rate brachytherapy
title_full_unstemmed Monte Carlo modeling of the patient and treatment delivery complexities for high dose rate brachytherapy
title_sort monte carlo modeling of the patient and treatment delivery complexities for high dose rate brachytherapy
publishDate 2015
url http://repositorio.ipen.br:8080/xmlui/handle/123456789/25298
work_keys_str_mv AT fonsecagabrielp montecarlomodelingofthepatientandtreatmentdeliverycomplexitiesforhighdoseratebrachytherapy
AT fonsecagabrielp modelagempelometododemontecarlodopacienteedascomplexidadesdostratamentosbraquiterapicoscomaltataxadedose
_version_ 1718868795462778880
spelling ndltd-IBICT-oai-repositorio.ipen.br-123456789-252982019-01-21T19:59:07Z Monte Carlo modeling of the patient and treatment delivery complexities for high dose rate brachytherapy Modelagem pelo método de Monte Carlo do paciente e das complexidades dos tratamentos braquiterápicos com alta taxa de dose FONSECA, GABRIEL P. Helio Yoriyaz brachytherapy iridium 192 absorbed radiation doses monte carlo method algorithms calculation methods computer codes Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-12-10T16:54:22Z No. of bitstreams: 0 Made available in DSpace on 2015-12-10T16:54:22Z (GMT). No. of bitstreams: 0 Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) Tratamentos braquiterápicos são comumente realizados conforme o relatório da American Association of Physicists in Medicine (AAPM), Task Group report TG-43U1, o qual define o formalismo para cálculo de dose absorvida na água e não considera a composição dos materiais, densidades, dimensões do paciente e o efeito dos aplicadores. Estes efeitos podem ser significantes, conforme descrito pelo recente relatório da AAPM, Task Group report TG- 186, que define diretrizes para que sistemas de planejamento modernos, capazes de considerar as complexidades descritas acima, sejam implementados. Esta tese tem como objetivo contribuir para o aumento da exatidão dos planejamentos de tratamento braquiterápicos, seguindo as recomendações do TG-186 e indo além do mesmo. Um software foi desenvolvido para integrar planejamentos de tratamento e simulações pelo método de Monte Carlo (MC); modelos acurados, CAD-Mesh, foram utilizados para representar aplicadores braquiterápicos; Grandezas utilizadas para reportar dose absorvida, Dw,m (dose para água no meio) e Dm,m (dose para o meio no meio), foram calculadas para um tratamento de cabeça e pescoço, considerando a teoria para pequenas (SCT small cavity theory) e grandes cavidades (LCT large cavity theory); a componente da dose em razão do movimento da fonte foi avaliada para tratamentos de próstata e ginecológicos. Perfis de velocidade obtidos na literatura foram utilizados; medidas de velocidade de uma fonte braquiterapica foram realizadas com uma câmera de alta taxa de aquisição. Cálculos de dose obtidos usando MC (incluindo a composição e densidade dos tecidos, ar e o aplicador) mostram sobredoses de aproximadamente 5% dentro do volume alvo, em um tratamento ginecológico, quando comparados aos resultados obtidos com um meio homogêneo de água. Por sua vez, subdoses de aproximadamente 5% foram observadas ao considerar a composição dos tecidos e regiões com ar em um tratamento intersticial de braço. Um aplicador cilíndrico oco resultou na sobredose observada no caso ginecológico, ressaltando a necessidade de modelos acurados para representar os aplicadores. Os modelos CAD-Mesh utilizados incluem um aplicador Fletcher-Williamson, com blindagem, e um balão deformável para irradiação de mama. Os resultados obtidos com estes modelos são equivalentes aos obtidos com modelos geométricos convencionais. Este recurso pode ser conveniente para aplicadores complexos e/ou quando o projeto dos aplicadores for disponibilizado pelo fabricante. Cálculos de dose, com a composição real dos tecidos humanos, podem apresentar diferenças significativas em razão da grandeza adotada. Diferenças entre Dm,m e Dw,m (SCT ou LCT) chegam a 14% em razão da composição do osso. A metodologia adotada (SCT ou LCT) resulta em diferenças de até 28% para o osso e 36% para os dentes. A componente de dose de trânsito também pode levar a diferenças significativas, uma vez que baixas velocidades ou movimentos uniformemente acelerados foram descritos na literatura. Considerando a pior condição e sem incluir nenhuma correção no tempo de parada, a dose de trânsito pode chegar a 3% da dose prescrita para um caso ginecológico, com 4 cateteres, e até 11.1% da dose prescrita para um tratamento de próstata, com 16 cateteres. A dose de trânsito para a fonte avaliada (velocidade obtida experimentalmente) não é uniformemente distribuída e pode levar a sub ou sobredoses de até 1.4% das doses comumente prescritas (310 Gy). Os tópicos estudados são relevantes para tratamentos braquiterápicos e podem contribuir para o aumento de sua acurácia. Os efeitos estudados podem ser avaliados com o uso do software, associado a um código MC, desenvolvido. Tese (Doutorado em Tecnologia Nuclear) IPEN/T Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP FAPESP:11/01913-4 2015 2015-12-10T16:54:22Z 2015-12-10T16:54:22Z info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/doctoralThesis http://repositorio.ipen.br:8080/xmlui/handle/123456789/25298 info:eu-repo/semantics/openAccess 110 N reponame:Repositório Institucional do IPEN instname:Instituto de Pesquisas Energéticas e Nucleares instacron:IPEN