Avaliação de dados nucleares para dosimetria de nêutrons

Made available in DSpace on 2014-10-09T12:42:16Z (GMT). No. of bitstreams: 0 === Made available in DSpace on 2014-10-09T14:05:21Z (GMT). No. of bitstreams: 0 === Doses absorvidas e doses efetivas podem ser calculadas utilizando códigos computacionais de transporte de radiação. A qualidade desses cál...

Full description

Bibliographic Details
Main Author: TARDELLI, TIAGO C.
Other Authors: Helio Yoriyaz
Format: Others
Published: 2013
Subjects:
Online Access:http://repositorio.ipen.br:8080/xmlui/handle/123456789/10587
id ndltd-IBICT-oai-repositorio.ipen.br-123456789-10587
record_format oai_dc
spelling ndltd-IBICT-oai-repositorio.ipen.br-123456789-105872019-01-21T19:57:43Z Avaliação de dados nucleares para dosimetria de nêutrons Evaluation of nuclear data for neutron dosimetry TARDELLI, TIAGO C. Helio Yoriyaz neutron transport neutron emission neutron sources neutron flux neutron dosimetry interactions measurement radiation dose units nuclear energy data analysis computer codes monte carlo method Made available in DSpace on 2014-10-09T12:42:16Z (GMT). No. of bitstreams: 0 Made available in DSpace on 2014-10-09T14:05:21Z (GMT). No. of bitstreams: 0 Doses absorvidas e doses efetivas podem ser calculadas utilizando códigos computacionais de transporte de radiação. A qualidade desses cálculos depende dos dados nucleares, no entanto, são raras as informações sobre as diferenças nas doses causadas por diferentes bibliotecas. O objetivo desse estudo é comparar os valores de dose (absorvida e efetiva) obtidos utilizando diferentes bibliotecas de dados nucleares devido a uma fonte externa de nêutrons na faixa de 10-11 a 20 MeV. As bibliotecas de dados nucleares são: JENDL 4.0, JEFF 3.1.1 e ENDF/B-VII.0. Cálculos de doses foram realizados utilizando o código MCNPX considerando o modelo antropomórfico da ICRP-110. As diferenças nos valores das doses absorvidas utilizando as bibliotecas JEFF 3.1.1 e a ENDF/B.VII são pequenas, em torno de 1%, porém os resultados obtidos com a JENDL 4.0 apresentam diferenças de até 85 % compara aos resultados da ENDF/B-VII.0 e JEFF 3.1.1. Diferenças nas doses efetivas são em torno de 1,5% entre ENDF/B-VII.0 e JEFF 3.1.1, e 11 % entre ENDF/B-VII.0 e JENDL 4.0. Dissertação (Mestrado) IPEN/D Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP 2013 2014-10-09T12:42:16Z 2014-10-09T14:05:21Z 2014-10-09T12:42:16Z 2014-10-09T14:05:21Z info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/masterThesis http://repositorio.ipen.br:8080/xmlui/handle/123456789/10587 info:eu-repo/semantics/openAccess 157 N reponame:Repositório Institucional do IPEN instname:Instituto de Pesquisas Energéticas e Nucleares instacron:IPEN
collection NDLTD
format Others
sources NDLTD
topic neutron transport
neutron emission
neutron sources
neutron flux
neutron dosimetry
interactions
measurement
radiation dose units
nuclear energy
data analysis
computer codes
monte carlo method
spellingShingle neutron transport
neutron emission
neutron sources
neutron flux
neutron dosimetry
interactions
measurement
radiation dose units
nuclear energy
data analysis
computer codes
monte carlo method
TARDELLI, TIAGO C.
Avaliação de dados nucleares para dosimetria de nêutrons
description Made available in DSpace on 2014-10-09T12:42:16Z (GMT). No. of bitstreams: 0 === Made available in DSpace on 2014-10-09T14:05:21Z (GMT). No. of bitstreams: 0 === Doses absorvidas e doses efetivas podem ser calculadas utilizando códigos computacionais de transporte de radiação. A qualidade desses cálculos depende dos dados nucleares, no entanto, são raras as informações sobre as diferenças nas doses causadas por diferentes bibliotecas. O objetivo desse estudo é comparar os valores de dose (absorvida e efetiva) obtidos utilizando diferentes bibliotecas de dados nucleares devido a uma fonte externa de nêutrons na faixa de 10-11 a 20 MeV. As bibliotecas de dados nucleares são: JENDL 4.0, JEFF 3.1.1 e ENDF/B-VII.0. Cálculos de doses foram realizados utilizando o código MCNPX considerando o modelo antropomórfico da ICRP-110. As diferenças nos valores das doses absorvidas utilizando as bibliotecas JEFF 3.1.1 e a ENDF/B.VII são pequenas, em torno de 1%, porém os resultados obtidos com a JENDL 4.0 apresentam diferenças de até 85 % compara aos resultados da ENDF/B-VII.0 e JEFF 3.1.1. Diferenças nas doses efetivas são em torno de 1,5% entre ENDF/B-VII.0 e JEFF 3.1.1, e 11 % entre ENDF/B-VII.0 e JENDL 4.0. === Dissertação (Mestrado) === IPEN/D === Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
author2 Helio Yoriyaz
author_facet Helio Yoriyaz
TARDELLI, TIAGO C.
author TARDELLI, TIAGO C.
author_sort TARDELLI, TIAGO C.
title Avaliação de dados nucleares para dosimetria de nêutrons
title_short Avaliação de dados nucleares para dosimetria de nêutrons
title_full Avaliação de dados nucleares para dosimetria de nêutrons
title_fullStr Avaliação de dados nucleares para dosimetria de nêutrons
title_full_unstemmed Avaliação de dados nucleares para dosimetria de nêutrons
title_sort avaliação de dados nucleares para dosimetria de nêutrons
publishDate 2013
url http://repositorio.ipen.br:8080/xmlui/handle/123456789/10587
work_keys_str_mv AT tardellitiagoc avaliacaodedadosnuclearesparadosimetriadeneutrons
AT tardellitiagoc evaluationofnucleardataforneutrondosimetry
_version_ 1718868189908041728