Nova metodologia para identificação de pontos críticos de desempenho em linhas de transmissão baseada na aplicação de sistemas de localização de descargas atmosféricas

=== The modern Lightning Location Systems (LLS) are the most advanced tool to provide lightning data in a wide scale range. Despite the LLS potentiality, the use of LLS data to support the design and operation activities in electric power systems is still relatively poor. In this work an original m...

Full description

Bibliographic Details
Main Author: Rosilene Nietzsch Dias
Other Authors: Silverio Visacro Filho
Format: Others
Language:Portuguese
Published: Universidade Federal de Minas Gerais 2006
Online Access:http://hdl.handle.net/1843/SVFO-6XQNDX
id ndltd-IBICT-oai-bibliotecadigital.ufmg.br-MTD2BR-SVFO-6XQNDX
record_format oai_dc
spelling ndltd-IBICT-oai-bibliotecadigital.ufmg.br-MTD2BR-SVFO-6XQNDX2019-01-21T17:51:24Z Nova metodologia para identificação de pontos críticos de desempenho em linhas de transmissão baseada na aplicação de sistemas de localização de descargas atmosféricas Rosilene Nietzsch Dias Silverio Visacro Filho The modern Lightning Location Systems (LLS) are the most advanced tool to provide lightning data in a wide scale range. Despite the LLS potentiality, the use of LLS data to support the design and operation activities in electric power systems is still relatively poor. In this work an original methodology was developed. It explores the application of LLS data combined to evaluations based on transmission line data to define critical spots along the line in terms of lightning performance. This allows determining the structures (towers or poles) where protection investments are recommended. The methodology is based on the determination of backflashover risk for each transmission line structure. The methodology was applied to real transmission lines and good results were achieved. Os modernos Sistemas de Localização de Descargas Atmosféricas (LLS) constituem-se na mais avançada ferramenta para aquisição de dados de descargas atmosféricas em larga escala. A despeito de sua potencialidade, a aplicação destes sistemas para suporte às atividades de projeto e operação de Sistemas Elétricos de Potência é ainda relativamente pobre. Neste trabalho foi desenvolvida uma metodologia original, que explora a aplicação do LLS em conjunto com avaliações baseadas em dados de linhas de transmissão para definir os pontos críticos das mesmas quanto ao desempenho frente a descargas atmosféricas e para indicar as torres críticas da linha. Nestas, devem ser concentrados os investimentos em proteção. A metodologia se baseia na determinação do risco de ocorrência de backflashover por torre da linha. A metodologia foi aplicada a linhas de transmissão reais, apresentando resultados satisfatórios. 2006-12-01 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/doctoralThesis http://hdl.handle.net/1843/SVFO-6XQNDX por info:eu-repo/semantics/openAccess text/html Universidade Federal de Minas Gerais 32001010015P8 - ENGENHARIA ELÉTRICA UFMG BR reponame:Biblioteca Digital de Teses e Dissertações da UFMG instname:Universidade Federal de Minas Gerais instacron:UFMG
collection NDLTD
language Portuguese
format Others
sources NDLTD
description === The modern Lightning Location Systems (LLS) are the most advanced tool to provide lightning data in a wide scale range. Despite the LLS potentiality, the use of LLS data to support the design and operation activities in electric power systems is still relatively poor. In this work an original methodology was developed. It explores the application of LLS data combined to evaluations based on transmission line data to define critical spots along the line in terms of lightning performance. This allows determining the structures (towers or poles) where protection investments are recommended. The methodology is based on the determination of backflashover risk for each transmission line structure. The methodology was applied to real transmission lines and good results were achieved. === Os modernos Sistemas de Localização de Descargas Atmosféricas (LLS) constituem-se na mais avançada ferramenta para aquisição de dados de descargas atmosféricas em larga escala. A despeito de sua potencialidade, a aplicação destes sistemas para suporte às atividades de projeto e operação de Sistemas Elétricos de Potência é ainda relativamente pobre. Neste trabalho foi desenvolvida uma metodologia original, que explora a aplicação do LLS em conjunto com avaliações baseadas em dados de linhas de transmissão para definir os pontos críticos das mesmas quanto ao desempenho frente a descargas atmosféricas e para indicar as torres críticas da linha. Nestas, devem ser concentrados os investimentos em proteção. A metodologia se baseia na determinação do risco de ocorrência de backflashover por torre da linha. A metodologia foi aplicada a linhas de transmissão reais, apresentando resultados satisfatórios.
author2 Silverio Visacro Filho
author_facet Silverio Visacro Filho
Rosilene Nietzsch Dias
author Rosilene Nietzsch Dias
spellingShingle Rosilene Nietzsch Dias
Nova metodologia para identificação de pontos críticos de desempenho em linhas de transmissão baseada na aplicação de sistemas de localização de descargas atmosféricas
author_sort Rosilene Nietzsch Dias
title Nova metodologia para identificação de pontos críticos de desempenho em linhas de transmissão baseada na aplicação de sistemas de localização de descargas atmosféricas
title_short Nova metodologia para identificação de pontos críticos de desempenho em linhas de transmissão baseada na aplicação de sistemas de localização de descargas atmosféricas
title_full Nova metodologia para identificação de pontos críticos de desempenho em linhas de transmissão baseada na aplicação de sistemas de localização de descargas atmosféricas
title_fullStr Nova metodologia para identificação de pontos críticos de desempenho em linhas de transmissão baseada na aplicação de sistemas de localização de descargas atmosféricas
title_full_unstemmed Nova metodologia para identificação de pontos críticos de desempenho em linhas de transmissão baseada na aplicação de sistemas de localização de descargas atmosféricas
title_sort nova metodologia para identificação de pontos críticos de desempenho em linhas de transmissão baseada na aplicação de sistemas de localização de descargas atmosféricas
publisher Universidade Federal de Minas Gerais
publishDate 2006
url http://hdl.handle.net/1843/SVFO-6XQNDX
work_keys_str_mv AT rosilenenietzschdias novametodologiaparaidentificacaodepontoscriticosdedesempenhoemlinhasdetransmissaobaseadanaaplicacaodesistemasdelocalizacaodedescargasatmosfericas
_version_ 1718843422883708928