Projeto de uma bancada de testes para avaliação do carregamento detransformadores trifásicos de potência utilizando conversores estáticos

=== This work presents the design of a setup for load tests in power transformers, mainly in adverse conditions. Such operation conditions can reduce life expectancy of the power transformers, mainly if it operates overload for long periods. The overload capabilities depend primarily on the winding...

Full description

Bibliographic Details
Main Author: Clodualdo Venicio de Sousa
Other Authors: Selenio Rocha Silva
Format: Others
Language:Portuguese
Published: Universidade Federal de Minas Gerais 2007
Online Access:http://hdl.handle.net/1843/BUOS-8CUG46
id ndltd-IBICT-oai-bibliotecadigital.ufmg.br-MTD2BR-BUOS-8CUG46
record_format oai_dc
spelling ndltd-IBICT-oai-bibliotecadigital.ufmg.br-MTD2BR-BUOS-8CUG462019-01-21T17:57:01Z Projeto de uma bancada de testes para avaliação do carregamento detransformadores trifásicos de potência utilizando conversores estáticos Clodualdo Venicio de Sousa Selenio Rocha Silva This work presents the design of a setup for load tests in power transformers, mainly in adverse conditions. Such operation conditions can reduce life expectancy of the power transformers, mainly if it operates overload for long periods. The overload capabilities depend primarily on the winding temperature. A novel scheme to perform load test in power transformers using reversible power converters is presented. The use of the reversible static converter for the load control of the transformer allows the independent control of the active and reactive power, in both directions, allowing instantaneous and automatic load control as well as voltage regulation. The power spent to perform the test represents only the losses in the transformer, filters and converters. The final goal of designed setup is to allow the test in laboratory, where overload and over-voltage operations can be explored. With this condition, the temperature variation of the transformer windings, insulation and core will be monitored. Simulation results are presented to evaluate the system behavior in order to show that the scheme feasible Este trabalho apresenta, o projeto do circuito de potência e dos controles de uma bancada de teste para implementação de ensaio de carregamento em transformadores de potência, em condições adversas de funcionamento. Estas condições de operação podem reduzir a vida útil dos transformadores de potência, principalmente, se operarem com sobrecarga em longos períodos. Assim, é apresentado um novo esquema para realizar teste de carrega- mento em transformadores de potência, usando conversores reversíveis. O uso de conversores estáticos para o controle de carga dos transformadores, possibilita o controle independente da potência ativa e reativa, em ambas as direções de fluxo, permitindo o controle automático do carregamento e a regulação da tensão. A potência gasta para realizar o ensaio, com esta topologia, representa apenas as perdas nos transformadores, filtros e conversores. O objetivo desta bancada projetada é permitir realização dos testes, em ambiente laboratorial, onde podem ser explorados pontos de operação com sobrecarga e sobretensão. Com estas condições de operação, a variação da temperatura no enrolamento do transformador, isolamento e núcleo podem ser monitorados a todo instante. Resultados de simulação são apresentados para verificar o comportamento do sistema e mostrar que o esquema é viável 2007-03-29 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/masterThesis http://hdl.handle.net/1843/BUOS-8CUG46 por info:eu-repo/semantics/openAccess text/html Universidade Federal de Minas Gerais 32001010015P8 - ENGENHARIA ELÉTRICA UFMG BR reponame:Biblioteca Digital de Teses e Dissertações da UFMG instname:Universidade Federal de Minas Gerais instacron:UFMG
collection NDLTD
language Portuguese
format Others
sources NDLTD
description === This work presents the design of a setup for load tests in power transformers, mainly in adverse conditions. Such operation conditions can reduce life expectancy of the power transformers, mainly if it operates overload for long periods. The overload capabilities depend primarily on the winding temperature. A novel scheme to perform load test in power transformers using reversible power converters is presented. The use of the reversible static converter for the load control of the transformer allows the independent control of the active and reactive power, in both directions, allowing instantaneous and automatic load control as well as voltage regulation. The power spent to perform the test represents only the losses in the transformer, filters and converters. The final goal of designed setup is to allow the test in laboratory, where overload and over-voltage operations can be explored. With this condition, the temperature variation of the transformer windings, insulation and core will be monitored. Simulation results are presented to evaluate the system behavior in order to show that the scheme feasible === Este trabalho apresenta, o projeto do circuito de potência e dos controles de uma bancada de teste para implementação de ensaio de carregamento em transformadores de potência, em condições adversas de funcionamento. Estas condições de operação podem reduzir a vida útil dos transformadores de potência, principalmente, se operarem com sobrecarga em longos períodos. Assim, é apresentado um novo esquema para realizar teste de carrega- mento em transformadores de potência, usando conversores reversíveis. O uso de conversores estáticos para o controle de carga dos transformadores, possibilita o controle independente da potência ativa e reativa, em ambas as direções de fluxo, permitindo o controle automático do carregamento e a regulação da tensão. A potência gasta para realizar o ensaio, com esta topologia, representa apenas as perdas nos transformadores, filtros e conversores. O objetivo desta bancada projetada é permitir realização dos testes, em ambiente laboratorial, onde podem ser explorados pontos de operação com sobrecarga e sobretensão. Com estas condições de operação, a variação da temperatura no enrolamento do transformador, isolamento e núcleo podem ser monitorados a todo instante. Resultados de simulação são apresentados para verificar o comportamento do sistema e mostrar que o esquema é viável
author2 Selenio Rocha Silva
author_facet Selenio Rocha Silva
Clodualdo Venicio de Sousa
author Clodualdo Venicio de Sousa
spellingShingle Clodualdo Venicio de Sousa
Projeto de uma bancada de testes para avaliação do carregamento detransformadores trifásicos de potência utilizando conversores estáticos
author_sort Clodualdo Venicio de Sousa
title Projeto de uma bancada de testes para avaliação do carregamento detransformadores trifásicos de potência utilizando conversores estáticos
title_short Projeto de uma bancada de testes para avaliação do carregamento detransformadores trifásicos de potência utilizando conversores estáticos
title_full Projeto de uma bancada de testes para avaliação do carregamento detransformadores trifásicos de potência utilizando conversores estáticos
title_fullStr Projeto de uma bancada de testes para avaliação do carregamento detransformadores trifásicos de potência utilizando conversores estáticos
title_full_unstemmed Projeto de uma bancada de testes para avaliação do carregamento detransformadores trifásicos de potência utilizando conversores estáticos
title_sort projeto de uma bancada de testes para avaliação do carregamento detransformadores trifásicos de potência utilizando conversores estáticos
publisher Universidade Federal de Minas Gerais
publishDate 2007
url http://hdl.handle.net/1843/BUOS-8CUG46
work_keys_str_mv AT clodualdoveniciodesousa projetodeumabancadadetestesparaavaliacaodocarregamentodetransformadorestrifasicosdepotenciautilizandoconversoresestaticos
_version_ 1718844402150932480