Cálculo de tensão induzida por descarga atmosférica em linhas aéreas de energia e cabos telefônicos: :uma aborgagem pela teoria de circuitos

=== This work proposes the calculation of induced voltages on overhead power lines and telephones cables by means of a commercial electric circuits simulator, aiming at avoiding the utilization of complex numerical codes specifically oriented to the problem. Up to this stage, the program developed...

Full description

Bibliographic Details
Main Author: Tarcisio Antonio Santos de Oliveira
Other Authors: Jose Osvaldo Saldanha Paulino
Format: Others
Language:Portuguese
Published: Universidade Federal de Minas Gerais 2001
Online Access:http://hdl.handle.net/1843/BUOS-8CJFF9
id ndltd-IBICT-oai-bibliotecadigital.ufmg.br-MTD2BR-BUOS-8CJFF9
record_format oai_dc
spelling ndltd-IBICT-oai-bibliotecadigital.ufmg.br-MTD2BR-BUOS-8CJFF92019-01-21T17:49:50Z Cálculo de tensão induzida por descarga atmosférica em linhas aéreas de energia e cabos telefônicos: :uma aborgagem pela teoria de circuitos Tarcisio Antonio Santos de Oliveira Jose Osvaldo Saldanha Paulino Antonio Emilio Angueth de Araujo Rodney Rezende Saldanha José Pissolato Filho Carlos Antônio França Sartori This work proposes the calculation of induced voltages on overhead power lines and telephones cables by means of a commercial electric circuits simulator, aiming at avoiding the utilization of complex numerical codes specifically oriented to the problem. Up to this stage, the program developed allows its application to multiconductor and multiple grounding overhead lines, as well as to telephone lines. Studies that analyze the incorporation of linghtning arresters and surge protection devices may be carried out, thus enabling the program to be used in studies on overvoltage protection for lines and sensitive eletronic equipment, and studies on electromagnetic compatibility. Several theoretical cases are analysed aiming at understanding the influence of linghtning discharge parameters in induced voltage in aerial lines and telephone cables that, in turn, are presented in several configurations. The results obtained are compared with similar results available in pertinent literature. Some simulations are also compared with experimental results obtained in the United States And in South Africa. Este trabalho propõe a implementação do cálculo de tensões induzidas em redes aeréas de energia elétrica e cabos telefônicos, utilizando um simulador comercial de circuitos elétricos, de forma a evitar a utilização de códigos numéricos complexos e especificamente orientados para o problema. O programa desenvolvido permite, até o presente estágio, sua aplicação em linhas aéreas mulitifilares e com aterramentos múltiplos, bem como em linhas telefônicas. Estudos analisando a incorporação de pára-raios ou de protetores contra surtos podem ser realizador, o que permite ao programa ser utilizado em estudos de proteção de linhas contra sobretensão, proteção de equipamentos eletrônicos sensíveis contra sobretensão e estudos de compatibilidade eletromagnética. Diversos casas teóricossão analisados, visando comprrender a influência dos parâmetros da descarga na tensão induzida em linhas aéreas e cabos telefônicos, que, por sua vez, são apresentados em diversas configurações. Os resultados obtidos são comparados com similares disponíveis na literatura. Algumas simulações são também comparadas com resultados experimentais obtidos na África do Sul e nos Estados Unidos. 2001-12-14 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/doctoralThesis http://hdl.handle.net/1843/BUOS-8CJFF9 por info:eu-repo/semantics/openAccess text/html Universidade Federal de Minas Gerais 32001010015P8 - ENGENHARIA ELÉTRICA UFMG BR reponame:Biblioteca Digital de Teses e Dissertações da UFMG instname:Universidade Federal de Minas Gerais instacron:UFMG
collection NDLTD
language Portuguese
format Others
sources NDLTD
description === This work proposes the calculation of induced voltages on overhead power lines and telephones cables by means of a commercial electric circuits simulator, aiming at avoiding the utilization of complex numerical codes specifically oriented to the problem. Up to this stage, the program developed allows its application to multiconductor and multiple grounding overhead lines, as well as to telephone lines. Studies that analyze the incorporation of linghtning arresters and surge protection devices may be carried out, thus enabling the program to be used in studies on overvoltage protection for lines and sensitive eletronic equipment, and studies on electromagnetic compatibility. Several theoretical cases are analysed aiming at understanding the influence of linghtning discharge parameters in induced voltage in aerial lines and telephone cables that, in turn, are presented in several configurations. The results obtained are compared with similar results available in pertinent literature. Some simulations are also compared with experimental results obtained in the United States And in South Africa. === Este trabalho propõe a implementação do cálculo de tensões induzidas em redes aeréas de energia elétrica e cabos telefônicos, utilizando um simulador comercial de circuitos elétricos, de forma a evitar a utilização de códigos numéricos complexos e especificamente orientados para o problema. O programa desenvolvido permite, até o presente estágio, sua aplicação em linhas aéreas mulitifilares e com aterramentos múltiplos, bem como em linhas telefônicas. Estudos analisando a incorporação de pára-raios ou de protetores contra surtos podem ser realizador, o que permite ao programa ser utilizado em estudos de proteção de linhas contra sobretensão, proteção de equipamentos eletrônicos sensíveis contra sobretensão e estudos de compatibilidade eletromagnética. Diversos casas teóricossão analisados, visando comprrender a influência dos parâmetros da descarga na tensão induzida em linhas aéreas e cabos telefônicos, que, por sua vez, são apresentados em diversas configurações. Os resultados obtidos são comparados com similares disponíveis na literatura. Algumas simulações são também comparadas com resultados experimentais obtidos na África do Sul e nos Estados Unidos.
author2 Jose Osvaldo Saldanha Paulino
author_facet Jose Osvaldo Saldanha Paulino
Tarcisio Antonio Santos de Oliveira
author Tarcisio Antonio Santos de Oliveira
spellingShingle Tarcisio Antonio Santos de Oliveira
Cálculo de tensão induzida por descarga atmosférica em linhas aéreas de energia e cabos telefônicos: :uma aborgagem pela teoria de circuitos
author_sort Tarcisio Antonio Santos de Oliveira
title Cálculo de tensão induzida por descarga atmosférica em linhas aéreas de energia e cabos telefônicos: :uma aborgagem pela teoria de circuitos
title_short Cálculo de tensão induzida por descarga atmosférica em linhas aéreas de energia e cabos telefônicos: :uma aborgagem pela teoria de circuitos
title_full Cálculo de tensão induzida por descarga atmosférica em linhas aéreas de energia e cabos telefônicos: :uma aborgagem pela teoria de circuitos
title_fullStr Cálculo de tensão induzida por descarga atmosférica em linhas aéreas de energia e cabos telefônicos: :uma aborgagem pela teoria de circuitos
title_full_unstemmed Cálculo de tensão induzida por descarga atmosférica em linhas aéreas de energia e cabos telefônicos: :uma aborgagem pela teoria de circuitos
title_sort cálculo de tensão induzida por descarga atmosférica em linhas aéreas de energia e cabos telefônicos: :uma aborgagem pela teoria de circuitos
publisher Universidade Federal de Minas Gerais
publishDate 2001
url http://hdl.handle.net/1843/BUOS-8CJFF9
work_keys_str_mv AT tarcisioantoniosantosdeoliveira calculodetensaoinduzidapordescargaatmosfericaemlinhasaereasdeenergiaecabostelefonicosumaaborgagempelateoriadecircuitos
_version_ 1718842600752939008