Análise de resposta em frequência aplicada em transformadores de potência

=== This work deals with the frequency response analysis applied to power transformers. An approach was given to the measurement methods of the signature to support futures studies on the mechanical faults diagnosis. During the research, a measurement system was developed based on the Auto-Balanced...

Full description

Bibliographic Details
Main Author: Ezequiel Rabelo de Aguiar
Other Authors: Jose Luiz Silvino
Format: Others
Language:Portuguese
Published: Universidade Federal de Minas Gerais 2007
Online Access:http://hdl.handle.net/1843/BUOS-8CBFAB
id ndltd-IBICT-oai-bibliotecadigital.ufmg.br-MTD2BR-BUOS-8CBFAB
record_format oai_dc
spelling ndltd-IBICT-oai-bibliotecadigital.ufmg.br-MTD2BR-BUOS-8CBFAB2019-01-21T18:01:12Z Análise de resposta em frequência aplicada em transformadores de potência Ezequiel Rabelo de Aguiar Jose Luiz Silvino This work deals with the frequency response analysis applied to power transformers. An approach was given to the measurement methods of the signature to support futures studies on the mechanical faults diagnosis. During the research, a measurement system was developed based on the Auto-Balanced Bridge method. The system performs tests and measurements of automatized form, by means of the frequency sweepings, and can be applied in field (substation). Also an equivalent circuit model was considered for the representation of the windingsin the frequency domain. It was based on measurements implemented in real power transformers and describes the main physical phenomena of the windings. Este trabalho trata da análise da resposta em frequência aplicada em transformadores de potência. Foi dado um enfoque aos métodos de medição da assinatura para cercear futuros estudos sobre o diagnóstico de faltas mecânicas. Durante a pesquisa, foi desenvolvido um sistema de medição baseado no método de Ponte Auto-Balanceada. O sistema realiza os testes e medições de forma automatizada, por meio da varredura de frequência, e pode ser aplicado em campo (subestação).Também foi proposto um modelo de circuito equivalente para a representação dos enrolamentos no domínio da frequência. Ele foi baseado em medições realizadas em transformadores de potência reais e descreve os fenômenos físicos principais dos enrolamentos. 2007-04-11 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/masterThesis http://hdl.handle.net/1843/BUOS-8CBFAB por info:eu-repo/semantics/openAccess text/html Universidade Federal de Minas Gerais 32001010015P8 - ENGENHARIA ELÉTRICA UFMG BR reponame:Biblioteca Digital de Teses e Dissertações da UFMG instname:Universidade Federal de Minas Gerais instacron:UFMG
collection NDLTD
language Portuguese
format Others
sources NDLTD
description === This work deals with the frequency response analysis applied to power transformers. An approach was given to the measurement methods of the signature to support futures studies on the mechanical faults diagnosis. During the research, a measurement system was developed based on the Auto-Balanced Bridge method. The system performs tests and measurements of automatized form, by means of the frequency sweepings, and can be applied in field (substation). Also an equivalent circuit model was considered for the representation of the windingsin the frequency domain. It was based on measurements implemented in real power transformers and describes the main physical phenomena of the windings. === Este trabalho trata da análise da resposta em frequência aplicada em transformadores de potência. Foi dado um enfoque aos métodos de medição da assinatura para cercear futuros estudos sobre o diagnóstico de faltas mecânicas. Durante a pesquisa, foi desenvolvido um sistema de medição baseado no método de Ponte Auto-Balanceada. O sistema realiza os testes e medições de forma automatizada, por meio da varredura de frequência, e pode ser aplicado em campo (subestação).Também foi proposto um modelo de circuito equivalente para a representação dos enrolamentos no domínio da frequência. Ele foi baseado em medições realizadas em transformadores de potência reais e descreve os fenômenos físicos principais dos enrolamentos.
author2 Jose Luiz Silvino
author_facet Jose Luiz Silvino
Ezequiel Rabelo de Aguiar
author Ezequiel Rabelo de Aguiar
spellingShingle Ezequiel Rabelo de Aguiar
Análise de resposta em frequência aplicada em transformadores de potência
author_sort Ezequiel Rabelo de Aguiar
title Análise de resposta em frequência aplicada em transformadores de potência
title_short Análise de resposta em frequência aplicada em transformadores de potência
title_full Análise de resposta em frequência aplicada em transformadores de potência
title_fullStr Análise de resposta em frequência aplicada em transformadores de potência
title_full_unstemmed Análise de resposta em frequência aplicada em transformadores de potência
title_sort análise de resposta em frequência aplicada em transformadores de potência
publisher Universidade Federal de Minas Gerais
publishDate 2007
url http://hdl.handle.net/1843/BUOS-8CBFAB
work_keys_str_mv AT ezequielrabelodeaguiar analisederespostaemfrequenciaaplicadaemtransformadoresdepotencia
_version_ 1718845592188223488