Determinação do ponto de corte, sensibilidade e especificidade do ELISA rgp90 para o diagnóstico da anemia infecciosa eqüina utilizando o modelo Bayesiano.

=== Equine infectious anemia (EIA) is caused by a retrovirus. The EIAV infected animal represents the main source of virus and the diagnosis of disease through clinical signs is not reliable. The availability of diagnostic tests marked the beginning of disease control by proof correlation with the...

Full description

Bibliographic Details
Main Author: Rejane Silva Diniz
Other Authors: Joao Paulo Amaral Haddad
Format: Others
Language:Portuguese
Published: Universidade Federal de Minas Gerais 2009
Online Access:http://hdl.handle.net/1843/BUOS-8C6FFP
id ndltd-IBICT-oai-bibliotecadigital.ufmg.br-MTD2BR-BUOS-8C6FFP
record_format oai_dc
spelling ndltd-IBICT-oai-bibliotecadigital.ufmg.br-MTD2BR-BUOS-8C6FFP2019-01-21T17:50:35Z Determinação do ponto de corte, sensibilidade e especificidade do ELISA rgp90 para o diagnóstico da anemia infecciosa eqüina utilizando o modelo Bayesiano. Rejane Silva Diniz Joao Paulo Amaral Haddad Marcelo Fernandes Camargos Paulo Roberto de Oliveira Equine infectious anemia (EIA) is caused by a retrovirus. The EIAV infected animal represents the main source of virus and the diagnosis of disease through clinical signs is not reliable. The availability of diagnostic tests marked the beginning of disease control by proof correlation with the presence of virus infection. These methods often have limitations attributable to the uncertainty of sensitivity and specificity estimates. Thus it is necessary studies of validation. In order to study these variations in specificity and sensitivity results of two diagnostic tests AGID and ELISA rgp90 were evaluated by statistical approach to estimate uncertainty for the diagnosis of EIA. The first, ROC curve, assessed values of optical density for the ELISA rgp90 as a parameter to select the optimal cut-off through the positive and negative results likelihood, the correct classification of results, an individual and accumulated sensitivity and specificity. The second, the Bayesian model, estimates the sensitivity and the specificity of two diagnostic tests in the absence of a Gold Standard. The posterior distribution computed with Bayesian analysis was compared considering just one test and both combined as well. The analysis of the area under the ROC curve and Bayesian analysis revealed the best accurate results when cut-off of 0.228 was established enabling the most discrimination between infected and non-infected approaching to improve the diagnosis of equine infectious anemia. A anemia infecciosa eqüina (AIE) é causada por um retrovírus. O animal infectado representa a principal fonte de vírus e o diagnóstico da doença através de sinais clínicos não é confiável. A disponibilidade dos testes diagnósticos marcou o início do controle da doença por demonstrarem correlação com a presença do vírus. No entanto, esses métodos frequentemente apresentam limitações atribuíveis a incerteza da estimativa da sensibilidade e especificidade sendo necessário estudos de validação. Nesse sentido resultados de dois testes diagnósticos IDGA e ELISA rgp90, foram avaliados através de testes estatísticos para estimar a incerteza no diagnóstico da AIE. O primeiro, a curva ROC, avaliou o ponto de corte para o imunoensaio ELISA rgp90 considerando como parâmetro para decisão do melhor cut off a Likelihood positivo e negativo, a classificação correta dos resultados, a sensibilidade e especificidade individuais e acumuladas. O segundo, o modelo Bayesiano, verifica a sensibilidade e especificidade dos dois testes considerando o diagnóstico na ausência do Gold standard. As distribuições a posteriori obtidas na análise Bayesiana foram comparadas considerando os testes isolados e combinados. A análise da área sob a curva ROC e a análise Bayesiana evidenciaram uma melhor acurácia com o ponto de corte 0,228 possibilitando o aumento da discriminação entre infectado e não infectado favorecendo a melhoria do diagnóstico da anemia infecciosa eqüina. 2009-10-23 info:eu-repo/semantics/publishedVersion info:eu-repo/semantics/masterThesis http://hdl.handle.net/1843/BUOS-8C6FFP por info:eu-repo/semantics/openAccess text/html Universidade Federal de Minas Gerais 32001010030P7 - MEDICINA VETERINÁRIA UFMG BR reponame:Biblioteca Digital de Teses e Dissertações da UFMG instname:Universidade Federal de Minas Gerais instacron:UFMG
collection NDLTD
language Portuguese
format Others
sources NDLTD
description === Equine infectious anemia (EIA) is caused by a retrovirus. The EIAV infected animal represents the main source of virus and the diagnosis of disease through clinical signs is not reliable. The availability of diagnostic tests marked the beginning of disease control by proof correlation with the presence of virus infection. These methods often have limitations attributable to the uncertainty of sensitivity and specificity estimates. Thus it is necessary studies of validation. In order to study these variations in specificity and sensitivity results of two diagnostic tests AGID and ELISA rgp90 were evaluated by statistical approach to estimate uncertainty for the diagnosis of EIA. The first, ROC curve, assessed values of optical density for the ELISA rgp90 as a parameter to select the optimal cut-off through the positive and negative results likelihood, the correct classification of results, an individual and accumulated sensitivity and specificity. The second, the Bayesian model, estimates the sensitivity and the specificity of two diagnostic tests in the absence of a Gold Standard. The posterior distribution computed with Bayesian analysis was compared considering just one test and both combined as well. The analysis of the area under the ROC curve and Bayesian analysis revealed the best accurate results when cut-off of 0.228 was established enabling the most discrimination between infected and non-infected approaching to improve the diagnosis of equine infectious anemia. === A anemia infecciosa eqüina (AIE) é causada por um retrovírus. O animal infectado representa a principal fonte de vírus e o diagnóstico da doença através de sinais clínicos não é confiável. A disponibilidade dos testes diagnósticos marcou o início do controle da doença por demonstrarem correlação com a presença do vírus. No entanto, esses métodos frequentemente apresentam limitações atribuíveis a incerteza da estimativa da sensibilidade e especificidade sendo necessário estudos de validação. Nesse sentido resultados de dois testes diagnósticos IDGA e ELISA rgp90, foram avaliados através de testes estatísticos para estimar a incerteza no diagnóstico da AIE. O primeiro, a curva ROC, avaliou o ponto de corte para o imunoensaio ELISA rgp90 considerando como parâmetro para decisão do melhor cut off a Likelihood positivo e negativo, a classificação correta dos resultados, a sensibilidade e especificidade individuais e acumuladas. O segundo, o modelo Bayesiano, verifica a sensibilidade e especificidade dos dois testes considerando o diagnóstico na ausência do Gold standard. As distribuições a posteriori obtidas na análise Bayesiana foram comparadas considerando os testes isolados e combinados. A análise da área sob a curva ROC e a análise Bayesiana evidenciaram uma melhor acurácia com o ponto de corte 0,228 possibilitando o aumento da discriminação entre infectado e não infectado favorecendo a melhoria do diagnóstico da anemia infecciosa eqüina.
author2 Joao Paulo Amaral Haddad
author_facet Joao Paulo Amaral Haddad
Rejane Silva Diniz
author Rejane Silva Diniz
spellingShingle Rejane Silva Diniz
Determinação do ponto de corte, sensibilidade e especificidade do ELISA rgp90 para o diagnóstico da anemia infecciosa eqüina utilizando o modelo Bayesiano.
author_sort Rejane Silva Diniz
title Determinação do ponto de corte, sensibilidade e especificidade do ELISA rgp90 para o diagnóstico da anemia infecciosa eqüina utilizando o modelo Bayesiano.
title_short Determinação do ponto de corte, sensibilidade e especificidade do ELISA rgp90 para o diagnóstico da anemia infecciosa eqüina utilizando o modelo Bayesiano.
title_full Determinação do ponto de corte, sensibilidade e especificidade do ELISA rgp90 para o diagnóstico da anemia infecciosa eqüina utilizando o modelo Bayesiano.
title_fullStr Determinação do ponto de corte, sensibilidade e especificidade do ELISA rgp90 para o diagnóstico da anemia infecciosa eqüina utilizando o modelo Bayesiano.
title_full_unstemmed Determinação do ponto de corte, sensibilidade e especificidade do ELISA rgp90 para o diagnóstico da anemia infecciosa eqüina utilizando o modelo Bayesiano.
title_sort determinação do ponto de corte, sensibilidade e especificidade do elisa rgp90 para o diagnóstico da anemia infecciosa eqüina utilizando o modelo bayesiano.
publisher Universidade Federal de Minas Gerais
publishDate 2009
url http://hdl.handle.net/1843/BUOS-8C6FFP
work_keys_str_mv AT rejanesilvadiniz determinacaodopontodecortesensibilidadeeespecificidadedoelisargp90paraodiagnosticodaanemiainfecciosaequinautilizandoomodelobayesiano
_version_ 1718842865151377408